Equivalent Circuit Model Viewed From Receiver Side in Human Body Communication
暂无分享,去创建一个
Fukuro Koshiji | Ken Sasaki | Dairoku Muramatsu | Yoshifumi Nishida | Kentaro Yamamoto | Y. Nishida | K. Sasaki | Kentaro Yamamoto | F. Koshiji | D. Muramatsu
[1] Hoi-Jun Yoo,et al. with Scalable Double-FSK Modulation , 2011 .
[2] Bo Zhao,et al. A Self-Adaptive Capacitive Compensation Technique for Body Channel Communication , 2017, IEEE Transactions on Biomedical Circuits and Systems.
[3] Yong-Xin Guo,et al. Investigation and Modeling of Capacitive Human Body Communication , 2017, IEEE Transactions on Biomedical Circuits and Systems.
[4] K. Fujii,et al. Electric Field Distributions of Wearable Devices Using the Human Body as a Transmission Channel , 2007, IEEE Transactions on Antennas and Propagation.
[5] Kenji Shiba,et al. Development of wearable intra-body communication devices , 2003 .
[6] Shreyas Sen,et al. Wearable health monitoring using capacitive voltage-mode Human Body Communication , 2017, 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
[7] Muhammad Irfan Kazim,et al. An Efficient Full-Wave Electromagnetic Analysis for Capacitive Body-Coupled Communication , 2015 .
[8] Ken Sasaki,et al. Measurement of human body communication transmission characteristics at 20 MHz , 2015, 2015 9th International Symposium on Medical Information and Communication Technology (ISMICT).
[9] Fukuro Koshiji,et al. Evaluation of Ground Loop Through the Floor in Human Body Communication , 2017, Int. J. Wirel. Inf. Networks.
[10] Kohji Koshiji,et al. A study on transmission characteristics and specific absorption rate using impedance-matched electrodes for various human body communication , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
[11] Javier Reina-Tosina,et al. Distributed Circuit Modeling of Galvanic and Capacitive Coupling for Intrabody Communication , 2012, IEEE Transactions on Biomedical Engineering.
[12] Yoshifumi Nishida,et al. Variation of impedance in transmission channel of human body communication , 2017, 2017 11th International Symposium on Medical Information and Communication Technology (ISMICT).
[13] Bo Zhao,et al. An Auto Loss Compensation System for Non-contact Capacitive Coupled Body Channel Communication , 2018, 2018 IEEE International Symposium on Circuits and Systems (ISCAS).
[14] Oliver Chiu-sing Choy,et al. Cascaded Network Body Channel Model for Intrabody Communication , 2016, IEEE Journal of Biomedical and Health Informatics.
[15] Muhammad Irfan Kazim,et al. Complex path impedance estimation and matching requirements for body-coupled communication , 2015, 2015 European Conference on Circuit Theory and Design (ECCTD).
[16] Nozomi Haga,et al. Equivalent Circuit of Intrabody Communication Channels Inducing Conduction Currents Inside the Human Body , 2013, IEEE Transactions on Antennas and Propagation.
[17] Ken Sasaki,et al. Transmission model of Human Body Communication incorporating size and distance between the two electrodes of a transmitter , 2016, 2016 International Conference on Electronics Packaging (ICEP).
[18] Yoshifumi Nishida,et al. Electromagnetic Field Analysis of Signal Transmission Path and Electrode Contact Conditions in Human Body Communication , 2018, Applied Sciences.
[19] Bo Zhao,et al. An Investigation on Ground Electrodes of Capacitive Coupling Human Body Communication , 2017, IEEE Transactions on Biomedical Circuits and Systems.
[20] Hoi-Jun Yoo,et al. The Signal Transmission Mechanism on the Surface of Human Body for Body Channel Communication , 2012, IEEE Transactions on Microwave Theory and Techniques.
[21] Fukuro Koshiji,et al. Impedance Matching andElectrode Structure Design for Wearable Transmitter in Intra-Body Transmission , 2009 .
[22] Ken Sasaki,et al. Maximization of Received Signal Power by Impedance Matching in Human Body Communication Receiver , 2015, BODYNETS.
[23] D. Muramatsu,et al. Transmission characteristics of wearable transmitter and stationary receiver through human body , 2016, 2016 International Conference on Electronics Packaging (ICEP).
[24] Oliver Chiu-sing Choy,et al. A 5.4-mW 180-cm Transmission Distance 2.5-Mb/s Advanced Techniques-Based Novel Intrabody Communication Receiver Analog Front End , 2015, IEEE Transactions on Very Large Scale Integration (VLSI) Systems.