Experimental realization of fluence field modulated CT using digital beam attenuation

Tailoring CT scan acquisition parameters to individual patients is a topic of much research in the CT imaging community. It is now common place to find automatically adjusted tube current options for modern CT scanners. In addition, the use of beam shaping filters, commonly called bowtie filters, is available on most CT systems and allows for different body regions to receive different incident x-ray fluence distributions. However, no method currently exists which allows for the form of the incident x-ray fluence distribution to change as a function of the view angle. This study represents the first experimental realization of fluence field modulated CT (FFMCT) for a c-arm geometry CT scan. X-ray fluence modulation is accomplished using a digital beam attenuator (DBA). The device is composed of ten iron wedge pairs that modulate the thickness of iron, the x-rays must traverse before reaching a patient. Using this device, experimental data was taken using a Siemens Zeego c-arm scanner. Scans were performed on a cylindrical polyethylene phantom and on two different sections of an anthropomorphic phantom. The DBA was used to equalize the x-ray fluence striking the detector for each scan. Non DBA, or 'flat field' scans were also acquired of the same phantom objects for comparison. In addition, a scan was performed in which the DBA was used to enable volume of interest (VOI) imaging. In VOI, only a small sub-volume within a patient receives full dose and the rest of the patient receives a much lower dose. Data corrections unique to using a piece-wise constant modulator were also developed. The feasibility of FFMCT implemented using a DBA device has been demonstrated. Initial results suggest dose reductions of up to 3.6 times relative to 'flat field' CT. In addition to dose reduction, the DBA enables a large improvement in image noise uniformity and the ability to provide regionally enhanced signal to noise using VOI imaging techniques. The results presented in this paper take the field of FFMCT from the theoretical stage to that of possible clinical implementation. FFMCT, as shown in this paper, can reduce the patient dose while maintaining or improving image quality. In addition, the DBA has been experimentally shown to be well suited to implement entirely new imaging methods like photon counting and VOI imaging.

[1]  Katsuyuki Taguchi,et al.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors. , 2010 .

[2]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[3]  W. Veldkamp,et al.  Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography: comparison of image quality in a phantom study. , 2005, Radiology.

[4]  Thomas Toth,et al.  The influence of patient centering on CT dose and image noise. , 2007, Medical physics.

[5]  Polad M Shikhaliev,et al.  Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector , 2009, Physics in medicine and biology.

[6]  D B Plewes,et al.  A scanning system for chest radiography with regional exposure control: practical implementation. , 1983, Medical physics.

[7]  Katsuyuki Taguchi,et al.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. , 2012, Radiology.

[8]  A. Kak Computerized tomography with X-ray, emission, and ultrasound sources , 1979, Proceedings of the IEEE.

[9]  Timothy P. Szczykutowicz,et al.  Design of a digital beam attenuation system for computed tomography: part I. System design and simulation framework. , 2013, Medical physics.

[10]  Norbert J. Pelc,et al.  Optimized control of a dynamic, prepatient attenuator , 2013, Medical Imaging.

[11]  Timothy P. Szczykutowicz,et al.  Practical considerations for intensity modulated CT , 2012, Medical Imaging.

[12]  David Jaffray,et al.  Fluence field optimization for noise and dose objectives in CT. , 2011, Medical physics.

[13]  S Molloi,et al.  X-ray beam equalization: feasibility and performance of an automated prototype system in a phantom and swine. , 2001, Radiology.

[14]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[15]  J H Siewerdsen,et al.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization. , 2004, Medical physics.

[16]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[17]  W A Kalender,et al.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. , 1999, Medical physics.

[18]  W A Kalender,et al.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. , 1999, Medical physics.

[19]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[20]  J H Siewerdsen,et al.  Compensators for dose and scatter management in cone-beam computed tomography. , 2007, Medical physics.

[21]  C. Shaw,et al.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging. , 2010, Medical physics.

[22]  Norbert J Pelc,et al.  The feasibility of a piecewise-linear dynamic bowtie filter. , 2013, Medical physics.

[23]  Daniel Kolditz,et al.  Volume-of-interest (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose. , 2010, Medical physics.

[24]  D B Plewes,et al.  A scanning system for chest radiography with regional exposure control: theoretical considerations. , 1983, Medical physics.

[25]  Timothy P. Szczykutowicz,et al.  Volume of interest CT implemented with a dynamic bowtie filter , 2013, Medical Imaging.

[26]  Dominic J. Heuscher,et al.  CT dose reduction using dynamic collimation , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[27]  Jonathan Sperl,et al.  Computer-Assisted Scan Protocol and Reconstruction (CASPAR)—Reduction of Image Noise and Patient Dose , 2010, IEEE Transactions on Medical Imaging.

[28]  C. Mistretta,et al.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results. , 2013, Medical physics.

[29]  S. Bartolac Fluence Field Modulated Computed Tomography , 2014 .

[30]  Tobias Funk,et al.  X-ray dose reduction by adaptive source equalization and electronic region-of-interest control , 2011, Medical Imaging.

[31]  Timothy P. Szczykutowicz,et al.  Intensity Modulated CT implemented with a dynamic bowtie filter , 2013, Medical Imaging.