Calculation of end–tidal carbon dioxide fractions in the Bain system

The validity of the Stenqvist–Sonander formula for calculating the end–expiratory fraction of carbon dioxide (FACO2) in the coaxial Mapleson D (Bain) systems was evaluated using a lung model for simulated spontaneous breathing with an optional respiratory wave form. Two different respiratory flow patterns were used, one representing relaxed breathing in a volunteer and one resembling the respiration found in halothane anaesthesia. Each pattern was used with five different fresh gas flows and three different respiratory rates. The formula was found to be quite accurate when the flow pattern of an awake volunteer was simulated, but it underestimated the observed FETCO2 value by about 10% in halothane breathing. It is concluded that the formula can be recommended for use in theoretical and educational situations but that it is too complicated for application in clinical practice.

[1]  H. Zetterström,et al.  Influence of the respiratory flow pattern on rebreathing in Mapleson A and D circuits , 1987, Acta anaesthesiologica Scandinavica.

[2]  H. Zetterström,et al.  Flow Pattern and Respiratory Characteristics during Halothane Anaesthesia , 1985, Acta anaesthesiologica Scandinavica.

[3]  H. Zetterström,et al.  Simulated Spontaneous Breathing. A New Model for Testing Anaesthetic Circuits , 1985, Acta anaesthesiologica Scandinavica.

[4]  O. Stenqvist,et al.  Rebreathing characteristics of the Bain circuit. An experimental and theoretical study. , 1984, British journal of anaesthesia.

[5]  A. Coates,et al.  An evaluation of rebreathing with the bain system during anaesthesia with spontaneous ventilation. , 1983, British journal of anaesthesia.

[6]  R. Byrick,et al.  Respiratory waveform and rebreathing in T-piece circuits: a comparison of enflurane and halothane waveforms. , 1980 .

[7]  J. Cruse,et al.  HALOTHANE IN AUTOIMMUNITY AND TUMORIGENESIS , 1980 .

[8]  J. Gabrielsen,et al.  Effect of Inspiration‐Expiration Ratio on Rebreathing with the Mapleson D System (Bain's Modification; Coaxial System) , 1980, Acta anaesthesiologica Scandinavica.

[9]  C. Conway,et al.  Spontaneous ventilation with the Bain anaesthetic system. , 1978, British journal of anaesthesia.

[10]  R. Byrick,et al.  Carbon dioxide elimination during spontaneous ventilation with a modified mapleson D system: Studies in a lung model , 1978, Canadian Anaesthetists' Society journal.

[11]  C. Conway,et al.  SPONTANEOUS VENTILATION WITH THE BAIN ANAESTHETIC SYSTEM , 1977 .

[12]  C. Conway Alveolar gas relationships during the use of semi-closed rebreathing anaesthetic systems. , 1976, British journal of anaesthesia.

[13]  W. Mapleson,et al.  Rebreathing in a T-piece: volunteer and theoretical studies of the Jackson-Rees modification of Ayre's T-piece during spontaneous respiration. , 1975, British journal of anaesthesia.

[14]  G. A. Harrison THE EFFECT OF THE RESPIRATORY FLOW PATTERN ON REBREATHING IN A T-PIECE SYSTEM. , 1964, British journal of anaesthesia.

[15]  W W MAPLESON,et al.  The elimination of rebreathing in various semi-closed anaesthetic systems. , 1954, British journal of anaesthesia.

[16]  J. A. Bain,et al.  Spontaneous respiration with the bain breathing circuit , 1978, Canadian Anaesthetists' Society journal.

[17]  Mapleson Ww Theoretical considerations of the effects of rebreathing in two semi-closed anaesthetic systems. , 1958 .