Monkey brain cortex imaging by use of photoacoustic tomography

Photoacoustic tomography (PAT) is adopted to image the brain cortex of monkeys through the intact scalp and skull ex vivo. The reconstructed PAT image shows the main structure of the blood vessels on the monkey brain cortex. For comparison, the brain cortex is imaged without the scalp then imaged again without the scalp and skull. Ultrasound attenuation through the skull is also measured at various angles of incidence to illuminate the effect of the incident angle. This study demonstrates that PAT of the brain cortex is capable of surviving the ultrasound signal attenuation and distortion caused by a considerably thick skull.

[1]  J. L. Thomas,et al.  Focusing and steering through absorbing and aberrating layers: application to ultrasonic propagation through the skull. , 1998, The Journal of the Acoustical Society of America.

[2]  Gregory T. Clement,et al.  Enhanced ultrasound transmission through the human skull using shear mode conversion. , 2004, The Journal of the Acoustical Society of America.

[3]  F. Fry,et al.  Ultrasonic diagnostic system for interactive interrogation of adult brain through intact skull. , 1982, Investigative radiology.

[4]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[5]  Minghua Xu,et al.  Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries , 2003, IEEE Transactions on Biomedical Engineering.

[6]  J. Campbell,et al.  Effect of the skull in degrading the display of echoencephalographic B and C scans. , 1968, The Journal of the Acoustical Society of America.

[7]  D H Evans,et al.  The effects of temporal bone on transcranial Doppler ultrasound beam shape. , 2000, Ultrasound in medicine & biology.

[8]  S.W. Smith,et al.  Phase-aberration correction with a 3-D ultrasound scanner: feasibility study , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  F. Fry,et al.  Transkull transmission of an intense focused ultrasonic beam. , 1977, Ultrasound in medicine & biology.

[10]  J L Thomas,et al.  Optimal focusing by spatio-temporal inverse filter. II. Experiments. Application to focusing through absorbing and reverberating media. , 2001, The Journal of the Acoustical Society of America.

[11]  V. I. Rimlyand,et al.  ULTRASONIC DIAGNOSTIC SYSTEM FOR ROTATING BODIES , 2001 .

[12]  T. Lazzarotto,et al.  Cranial ultrasound scanning and prediction of outcome in newborns with congenital cytomegalovirus infection. , 2007, The Journal of pediatrics.

[13]  P. VanBaren,et al.  Dynamic focusing in ultrasound hyperthermia treatments using implantable hydrophone arrays , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Yuan Xu,et al.  Rhesus monkey brain imaging through intact skull with thermoacoustic tomography , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  J. Oksman,et al.  Ultrasonic reflection mode computed tomography through a skullbone , 1990, IEEE Transactions on Biomedical Engineering.

[16]  Patrick D Wolf,et al.  Feasibility study: real-time 3-D ultrasound imaging of the brain. , 2004, Ultrasound in medicine & biology.

[17]  S. Schreiber,et al.  Transcranial ultrasonography of cerebral veins and sinuses. , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[18]  J. Barger,et al.  Acoustical properties of the human skull. , 1978, The Journal of the Acoustical Society of America.