Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

PURPOSE To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. DESIGN Prospective, comparative, nonrandomized, consecutive case series. PARTICIPANTS Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). METHODS All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. MAIN OUTCOME MEASURES Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. RESULTS A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). CONCLUSIONS The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters.

[1]  David A. Atchison,et al.  Decentred optical axes and aberrations along principal visual field meridians , 2009, Vision Research.

[2]  B. Kaluzny,et al.  [Microincision cataract surgery]. , 2005, Klinika oczna.

[3]  W. Charman,et al.  Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intraocular lenses. , 2008, Journal of refractive surgery.

[4]  Robert Montés-Micó,et al.  Crystalline lens optical dysfunction through aging. , 2005, Ophthalmology.

[5]  J. Alfonso,et al.  Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses , 2009, Journal of cataract and refractive surgery.

[6]  David P Piñero,et al.  Visual outcomes and optical performance of a monofocal intraocular lens and a new‐generation multifocal intraocular lens , 2011, Journal of cataract and refractive surgery.

[7]  Mujtaba A. Qazi,et al.  Visual performance of patients with bilateral vs combination Crystalens, ReZoom, and ReSTOR intraocular lens implants. , 2007, American journal of ophthalmology.

[8]  P. Chiam,et al.  Functional vision with bilateral ReZoom and ReSTOR intraocular lenses 6 months after cataract surgery , 2007, Journal of cataract and refractive surgery.

[9]  J. Alió,et al.  Design of short Spanish sentences for measuring reading performance: Radner‐Vissum test , 2008, Journal of cataract and refractive surgery.

[10]  J. Alió,et al.  Clinical outcomes and postoperative intraocular optical quality with a microincision aberration‐free aspheric intraocular lens , 2009, Journal of cataract and refractive surgery.

[11]  F Krummenauer,et al.  Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation. , 1999, Ophthalmology.

[12]  Robert Montés-Micó,et al.  Retinal image quality after microincision intraocular lens implantation , 2005, Journal of cataract and refractive surgery.

[13]  R. Lindstrom,et al.  Multifocal intraocular lenses , 1990, Journal of cataract and refractive surgery.

[14]  Stephen S. Lane,et al.  Optical performance of 3 intraocular lens designs in the presence of decentration , 2005, Journal of cataract and refractive surgery.

[15]  Robert Montés-Micó,et al.  Apodized diffractive versus refractive multifocal intraocular lenses: Optical and visual evaluation , 2008, Journal of cataract and refractive surgery.

[16]  J C Javitt,et al.  Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. , 2000, Ophthalmology.

[17]  J. Alió,et al.  Optical performance of monofocal and multifocal intraocular lenses in the human eye , 2008, Journal of cataract and refractive surgery.

[18]  Maria A. Woodward,et al.  Dissatisfaction after multifocal intraocular lens implantation , 2009, Journal of cataract and refractive surgery.

[19]  J T Holladay,et al.  Optical performance of multifocal intraocular lenses , 1990, Journal of cataract and refractive surgery.

[20]  Takashi Fujikado,et al.  Wavefront analysis in eyes with nuclear or cortical cataract. , 2002, American journal of ophthalmology.

[21]  L. Langan,et al.  Comparing the 1CU accommodative, multifocal, and monofocal intraocular lenses: a randomized trial. , 2008, Ophthalmology.

[22]  J. Alió,et al.  Grading nuclear cataract opacity by densitometry and objective optical analysis , 2008, Journal of cataract and refractive surgery.

[23]  J. Alió,et al.  Microincision multifocal intraocular lens with and without a capsular tension ring: Optical quality and clinical outcomes , 2008, Journal of cataract and refractive surgery.

[24]  M. Leyland,et al.  Multifocal versus monofocal intraocular lenses in cataract surgery: a systematic review. , 2003, Ophthalmology.

[25]  Jorge L Alió,et al.  Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses: Comparative clinical study , 2004, Journal of cataract and refractive surgery.

[26]  J. García-Feijóo,et al.  Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models , 2009, Journal of cataract and refractive surgery.

[27]  J. Alió,et al.  Visual and optical performance with two different diffractive multifocal intraocular lenses compared to a monofocal lens. , 2011, Journal of refractive surgery.

[28]  Roberto Bellucci,et al.  Multifocal intraocular lenses , 2005, Current opinion in ophthalmology.

[29]  M. Chalita,et al.  Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs. , 2005, Journal of refractive surgery.

[30]  Robert Montés-Micó,et al.  Distance and near contrast sensitivity function after multifocal intraocular lens implantation , 2003, Journal of cataract and refractive surgery.

[31]  Colm McAlinden,et al.  Multifocal intraocular lens with a surface‐embedded near section: Short‐term clinical outcomes , 2011, Journal of cataract and refractive surgery.

[32]  Yizhi Liu,et al.  Aberration and contrast sensitivity comparison of aspherical and monofocal and multifocal intraocular lens eyes , 2007, Clinical & experimental ophthalmology.

[33]  D. Chang Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or younger , 2008, Journal of cataract and refractive surgery.

[34]  Thomas Kohnen,et al.  European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens. , 2006, Ophthalmology.

[35]  Richard H. Keates,et al.  Clinical results of the multifocal lens , 1987, Journal of cataract and refractive surgery.

[36]  Jorge L Alió,et al.  Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution , 2008, Journal of cataract and refractive surgery.

[37]  T. Oshika,et al.  Ocular higher-order wavefront aberration caused by major tilting of intraocular lens. , 2005, American journal of ophthalmology.

[38]  R. Montés-Micó,et al.  Retinal straylight and complaint scores 18 months after implantation of the AcrySof monofocal and ReSTOR diffractive intraocular lenses. , 2009, Journal of refractive surgery.

[39]  Jason Turuwhenua,et al.  A theoretical study of intraocular lens tilt and decentration on perceptual image quality , 2005, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[40]  J. Alfonso,et al.  Prospective visual evaluation of apodized diffractive intraocular lenses , 2007, Journal of cataract and refractive surgery.

[41]  M. Vilaseca,et al.  Optical quality of foldable monofocal intraocular lenses before and after injection: Comparative evaluation using a double‐pass system , 2009, Journal of cataract and refractive surgery.

[42]  Takashi Fujikado,et al.  Wavefront analysis of higher‐order aberrations in patients with cataract , 2002, Journal of cataract and refractive surgery.

[43]  Jorge L Alió,et al.  Corneal aberrations after microincision cataract surgery , 2008, Journal of cataract and refractive surgery.

[44]  W. Hütz,et al.  Reading ability with 3 multifocal intraocular lens models , 2006, Journal of cataract and refractive surgery.

[45]  T. Walkow,et al.  Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parameters , 2001, Graefe's Archive for Clinical and Experimental Ophthalmology.

[46]  R. Steinert,et al.  A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens. , 1999, Ophthalmology.

[47]  S. Pieh,et al.  Halo size under distance and near conditions in refractive multifocal intraocular lenses , 2001, The British journal of ophthalmology.

[48]  H. Weghaupt,et al.  Reading performance with a refractive multifocal and a diffractive bifocal intraocular lens , 2002, Journal of cataract and refractive surgery.

[49]  Edwin J Sarver,et al.  Are all aberrations equal? , 2002, Journal of refractive surgery.