Full time-resolved diffuse fluorescence tomography accelerated with parallelized Fourier-series truncated diffusion approximation

Abstract. Of the three measurement schemes established for diffuse fluorescence tomography (DFT), the time-domain scheme is well known to provide the richest information about the distribution of the targeting fluorophore in living tissues. However, the explicit use of the full time-resolved data usually leads to a considerably lengthy time for image reconstruction, limiting its applications to three-dimensional or small-volume imaging. To cope with the adversity, we propose herein a computationally efficient scheme for DFT image reconstruction where the time-dependent photon density is expanded to a Fourier-series and calculated by solving the independent frequency-domain diffusion equations at multiple sampling frequencies with the support of a combined multicore CPU-based coarse-grain and multithread GPU-based fine-grain parallelization strategy. With such a parallelized Fourier-series truncated diffusion approximation, both the time- and frequency-domain inversion procedures are developed and validated for their effectiveness and accuracy using simulative and phantom experiments. The results show that the proposed method can generate reconstructions comparable to the explicit time-domain scheme, with significantly reduced computational time.

[1]  M. Schweiger,et al.  A finite element approach for modeling photon transport in tissue. , 1993, Medical physics.

[2]  Brian W Pogue,et al.  Toward whole-body optical imaging of rats using single-photon counting fluorescence tomography. , 2011, Optics letters.

[3]  F Lesage,et al.  Time Domain Fluorescent Diffuse Optical Tomography: analytical expressions. , 2005, Optics express.

[4]  Feng Gao,et al.  Improvement of image quality in diffuse optical tomography by use of full time-resolved data. , 2002, Applied optics.

[5]  M. Schweiger,et al.  Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans. , 2007, Optics express.

[6]  Aki Pulkkinen,et al.  Truncated Fourier-series approximation of the time-domain radiative transfer equation using finite elements. , 2013, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  Yujie Lu,et al.  Small animal fluorescence and bioluminescence tomography: a review of approaches, algorithms and technology update , 2014, Physics in medicine and biology.

[8]  Scott C Davis,et al.  Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications. , 2010, Journal of photochemistry and photobiology. B, Biology.

[9]  Dirk Grosenick,et al.  Nonlinear reconstruction of absorption and fluorescence contrast from measured diffuse transmittance and reflectance of a compressed-breast-simulating phantom. , 2009, Applied optics.

[10]  H. Dehghani,et al.  Diffuse optical imaging , 2009, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[11]  Feng Gao,et al.  Full domain-decomposition scheme for diffuse optical tomography of large-sized tissues with a combined CPU and GPU parallelization. , 2014, Applied optics.

[12]  C. Bouman,et al.  Fluorescence optical diffusion tomography. , 2003, Applied optics.

[13]  Hamid Dehghani,et al.  Multiple-gate time domain diffuse fluorescence tomography allows more sparse tissue sampling without compromising image quality. , 2012, Optics letters.

[14]  Eva M Sevick-Muraca,et al.  Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents. , 2002, Current opinion in chemical biology.

[15]  Feng Gao,et al.  Overlap time-gating approach for improving time-domain diffuse fluorescence tomography based on the IRF-calibrated Born normalization. , 2013, Optics letters.

[16]  Gregory Boverman,et al.  Time resolved fluorescence tomography of turbid media based on lifetime contrast. , 2006, Optics express.

[17]  A. Lent,et al.  Iterative algorithms for large partitioned linear systems, with applications to image reconstruction , 1981 .

[18]  Feng Gao,et al.  Combined hemoglobin and fluorescence diffuse optical tomography for breast tumor diagnosis: a pilot study on time-domain methodology , 2013, Biomedical optics express.

[19]  Wei Zhang,et al.  GPU-accelerated Monte-Carlo modeling for fluorescence propagation in turbid medium , 2012, BiOS.

[20]  Xavier Intes,et al.  Full-field time-resolved fluorescence tomography of small animals. , 2010, Optics letters.

[21]  Xavier Intes,et al.  Adaptive wide-field optical tomography , 2013, Journal of biomedical optics.

[22]  Feng Gao,et al.  A self-normalized, full time-resolved method for fluorescence diffuse optical tomography. , 2008, Optics express.

[23]  H Dehghani,et al.  A three-dimensional finite element model and image reconstruction algorithm for time-domain fluorescence imaging in highly scattering media , 2011, Physics in medicine and biology.

[24]  S R Arridge,et al.  Application of temporal filters to time resolved data in optical tomography , 1999, Physics in medicine and biology.

[25]  Zhao Hui-juan A Linear Featured-data Scheme for Image Reconstruction in Time-domain Fluorescence Molecular Tomography , 2008 .

[26]  A. Yodh,et al.  Diffuse optics for tissue monitoring and tomography , 2010, Reports on progress in physics. Physical Society.

[27]  David A Boas,et al.  Comparison of frequency-domain and time-domain fluorescence lifetime tomography. , 2008, Optics letters.