Passive Filter Design for China High-Speed Railway With Considering Harmonic Resonance and Characteristic Harmonics

In order to make high-speed trains (HSTs) lighter and more reliable, LC or LCL high-pass filters, which are widely adopted to mitigate high-order harmonics, are not installed in most of China HSTs. Therefore, the harmonic problem is a concern, because of the significant adverse impacts it has on the tractive drive system of the train and power quality of the utility system. The harmful harmonic distortions in high-speed railways (HSRs) are mainly caused by harmonic resonance and massive characteristic harmonics emission. This paper presents the results of harmonic assessment and harmonic filter design for a typical HSR line in China. Harmonic penetration analysis (HPA) is implemented and carried out to determine the harmonic distorted types for a wide range of possible train-operating conditions in a timetable. Both statistical field test and numerical calculation are used in passive filter design for HSRs. A C-type filter is designed here to address these typical harmonic distortions. The studies will be validated by detailed simulations based on the train timetable by counting the 95% index of the 24-h profile of harmonic results.

[1]  Dario Zaninelli,et al.  Harmonic disturbances in electric traction system overhead lines , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).

[2]  Hanmin Lee,et al.  Harmonic analysis of the korean high-speed railway using the eight-port representation model , 2006, IEEE Transactions on Power Delivery.

[3]  Wilsun Xu,et al.  Mitigation of harmonics in oil field electric systems using a centralized medium voltage filter , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[4]  G.W. Chang,et al.  Modeling characteristics of harmonic currents generated by high-speed railway traction drive converters , 2004, IEEE Transactions on Power Delivery.

[5]  N. Martins,et al.  A Newton-Raphson Method Based on Eigenvalue Sensitivities to Improve Harmonic Voltage Performance , 2002, IEEE Power Engineering Review.

[6]  G.W. Chang,et al.  A Probabilistic Approach for Optimal Passive Harmonic Filter Planning , 2007, IEEE Transactions on Power Delivery.

[7]  Morris Brenna,et al.  Analysis of the Filters Installed in the Interconnection Points Between Different Railway Supply Systems , 2012, IEEE Transactions on Smart Grid.

[8]  Zhengyou He,et al.  Harmonic Resonance Assessment to Traction Power-Supply System Considering Train Model in China High-Speed Railway , 2014, IEEE Transactions on Power Delivery.

[9]  S. Leva,et al.  Impact of High-Voltage Primary Supply Lines in the 2 $\times$ 25 kV–50 Hz Railway System on the Equivalent Impedance at Pantograph Terminals , 2012, IEEE Transactions on Power Delivery.

[10]  W. Freitas,et al.  Assessing the Collective Harmonic Impact of Modern Residential Loads—Part I: Methodology , 2012, IEEE Transactions on Power Delivery.

[11]  Angela Iagar,et al.  Analysis of electromagnetic pollution produced by line frequency coreless induction furnaces , 2009 .

[12]  Dario Zaninelli,et al.  Electromagnetic Model of High Speed Railway Lines for Power Quality Studies , 2010, IEEE Transactions on Power Systems.

[13]  Li Peng,et al.  A Novel Design and Optimization Method of an $LCL$ Filter for a Shunt Active Power Filter , 2014, IEEE Transactions on Industrial Electronics.

[14]  Wei-Jen Lee,et al.  A Survey of Harmonic Emissions of a Commercially Operated Wind Farm , 2010, IEEE Transactions on Industry Applications.

[15]  M. Joorabian,et al.  C-type filter design based on power-factor correction for 12-pulse HVDC converters , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[16]  Walmir Freitas,et al.  An Investigation on the Selection of Filter Topologies for Passive Filter Applications , 2009 .

[17]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[18]  Yun Wei Li,et al.  Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[19]  Fei Wang,et al.  Modeling and Analysis of Grid Harmonic Distortion Impact of Aggregated DG Inverters , 2011, IEEE Transactions on Power Electronics.

[20]  Zhengyou He,et al.  Modal Frequency Sensitivity Analysis and Application Using Complex Nodal Matrix , 2014, IEEE Transactions on Power Delivery.

[21]  S. Y. Chu,et al.  Strategic placement and sizing of passive filters in a power system for controlling voltage distortion , 2004 .

[22]  N.R. Watson,et al.  Implications for Distribution Networks of High Penetration of Compact Fluorescent Lamps , 2009, IEEE Transactions on Power Delivery.

[23]  Wilsun Xu,et al.  An Investigation on the Selection of Filter Topologies for Passive Filter Applications , 2009, IEEE Transactions on Power Delivery.