Super-Resolution Ultrasound Image Filtering with Machine-Learning to Reduce the Localization Error

Localization-based super-resolution imaging requires accurate detection of spatially isolated microbubbles. The reason for this requirement is that interfering or overlapping signals resulting from multiple microbubbles within the resolution limit can cause position errors. In addition to this, noise and artefacts (e.g. residual tissue signal after tissue-microbubble separation) further reduce the quality and hence the spatial resolution in SR imaging. Therefore, correctly identifying the echoes as noise, single microbubble, multiple microbubbles, or artefact is important.In this study, the use of fast classification methods for identification and rejection of non-single microbubble echoes were demonstrated. Most commonly used supervised classification methods, including Decision Trees, Discriminant Analysis, Logistic Regression, Support Vector Machine, Ensembles, k-Nearest Neighbors, and Naive Bayes, were implemented for filtering artefacts and noise in super-resolution ultrasound images. Results showed that the Ensemble method, explicitly designed to deal with unbalanced data, achieved the best result since most of the localized events are true microbubbles, which is typical for super-resolution imaging datasets.

[1]  Sevan Harput,et al.  Acoustic wave sparsely activated localization microscopy (AWSALM): Super-resolution ultrasound imaging using acoustic activation and deactivation of nanodroplets , 2018, Applied Physics Letters.

[2]  Katherine W. Ferrara,et al.  Acoustical structured illumination for super-resolution ultrasound imaging , 2018, Communications Biology.

[3]  Yonina C. Eldar,et al.  Sparsity-driven super-resolution in clinical contrast-enhanced ultrasound , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[4]  Armando Manduca,et al.  Improved Super-Resolution Ultrasound Microvessel Imaging With Spatiotemporal Nonlocal Means Filtering and Bipartite Graph-Based Microbubble Tracking , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[5]  Sevan Harput,et al.  Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[6]  Heechul Yoon,et al.  Super-Resolution Imaging With Ultrafast Ultrasound Imaging of Optically Triggered Perfluorohexane Nanodroplets , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[7]  Yonina C. Eldar,et al.  SUSHI: Sparsity-Based Ultrasound Super-Resolution Hemodynamic Imaging , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[8]  Piero Tortoli,et al.  Architecture of an Ultrasound System for Continuous Real-Time High Frame Rate Imaging , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  Sevan Harput,et al.  Fast Acoustic Wave Sparsely Activated Localization Microscopy: Ultrasound Super-Resolution Using Plane-Wave Activation of Nanodroplets , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[10]  Robert J. Eckersley,et al.  In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles , 2015, IEEE Transactions on Medical Imaging.

[11]  Mickael Tanter,et al.  Ultrasound Localization Microscopy and Super-Resolution: A State of the Art , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[12]  Mickael Tanter,et al.  Resolution limits of ultrafast ultrasound localization microscopy , 2015, Physics in medicine and biology.

[13]  Meaghan A. O'Reilly,et al.  A super-resolution ultrasound method for brain vascular mapping. , 2013, Medical physics.

[14]  Georg Schmitz,et al.  Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[15]  C. Dunsby,et al.  3D Super-Resolution US Imaging of Rabbit Lymph Node Vasculature in Vivo by Using Microbubbles. , 2019, Radiology.

[16]  Paul Aljabar,et al.  Microbubble Axial Localization Errors in Ultrasound Super-Resolution Imaging , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  Mickael Tanter,et al.  Ultrafast ultrasound localization microscopy , 2017 .

[18]  Sevan Harput,et al.  Localisation of multiple non-isolated microbubbles with frequency decomposition in super-resolution imaging , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[19]  Paul A. Dayton,et al.  3-D Ultrasound Localization Microscopy for Identifying Microvascular Morphology Features of Tumor Angiogenesis at a Resolution Beyond the Diffraction Limit of Conventional Ultrasound , 2017, Theranostics.

[20]  Charlie Demené,et al.  Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity , 2015, IEEE Transactions on Medical Imaging.

[21]  Mickael Tanter,et al.  Ultrafast 3D Ultrasound Localization Microscopy Using a 32 $\times$ 32 Matrix Array , 2019, IEEE Transactions on Medical Imaging.

[22]  Yonina C. Eldar,et al.  Sparsity-driven super-localization in clinical contrast-enhanced ultrasound , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[23]  Katherine W Ferrara,et al.  Ultrasound localization microscopy to image and assess microvasculature in a rat kidney , 2017, Scientific Reports.

[24]  S. Emelianov,et al.  Super-Resolution Ultrasound Imaging in Vivo with Transient Laser-Activated Nanodroplets. , 2016, Nano letters.

[25]  C Dunsby,et al.  Acoustic super-resolution with ultrasound and microbubbles , 2013, Physics in medicine and biology.

[26]  Matthieu Toulemonde,et al.  3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array , 2020, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[27]  Sevan Harput,et al.  3-D Motion Correction for Volumetric Super-Resolution Ultrasound Imaging , 2018, 2018 IEEE International Ultrasonics Symposium (IUS).

[28]  Piero Tortoli,et al.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[29]  Fabian Kiessling,et al.  Motion model ultrasound localization microscopy for preclinical and clinical multiparametric tumor characterization , 2018, Nature Communications.