pnCCDs on XMM-Newton: 42 months in orbit

Abstract XMM-Newton—a cornerstone mission of the European Space Agency's Horizon 2000 programme—was launched on December 10, 1999 into orbit. Since March 2000 more than 2000 scientific observations were made. An example will be shown. The X-ray pnCCD camera on EPIC is operating since then without severe problems. We will report about the system performance as a function of time, with special emphasis on the effect of radiation damage in orbit. Up to now the spectroscopic and imaging performance of the pnCCD camera system is stable with time, even at the lowest energies most sensitive to degradation. The deviations of the detector response compared to the prelaunch performance over the 3.5 years is below 0.5%. One year after launch, the pnCCD X-ray camera was hit by a micrometeoroid, damaging 35 pixels spread over the entire field of view. Details of the impact of the pnCCD with a cosmic dust particle will be given. X-ray fluorescence photons, stimulated by charged particles, constitute a significant part of the instrument background. Possible improvements for future missions will be discussed.

[1]  Norbert Meidinger,et al.  Evidence for micrometeoroid damage in the pn-CCD camera system aboard XMM-Newton , 2001 .

[2]  Peter Lechner,et al.  Ultrathin entrance windows for silicon drift detectors , 1997 .

[3]  Norbert Meidinger,et al.  First measurements with a frame store PN-CCD X-ray detector , 2003 .

[4]  Heinrich W. Braeuninger,et al.  Experimental verification of a micrometeoroid damage in the pn-CCD camera system aboard XMM-Newton , 2003, SPIE Astronomical Telescopes + Instrumentation.

[5]  Pavel Rehak,et al.  Semiconductor drift chamber: an application of a novel charge transport scheme , 1984 .

[6]  Eckhard Kendziorra,et al.  Effect of low-energy protons on the performance of the EPIC pn-CCD detector on XMM-Newton , 2000, SPIE Optics + Photonics.

[7]  Edgar Bihler,et al.  Quantum efficiency of the XMM pn-CCD camera , 1999, Optics & Photonics.

[8]  Norbert Meidinger,et al.  Radiation hardness of pn-CCDs for X-ray astronomy , 1995 .

[9]  Elena Belsole,et al.  In-orbit calibration activities of the XMM-Newton EPIC cameras , 2000, SPIE Optics + Photonics.

[10]  Elmar Pfeffermann,et al.  The European Photon Imaging Camera on XMM-Newton: The pn-CCD camera , 2001 .

[11]  Elmar Pfeffermann,et al.  A 36 cm2 large monolythic pn-charge coupled device x-ray detector for the European XMM satellite mission , 1997 .

[12]  Norbert Meidinger,et al.  Particle and X-ray damage in pn-CCDs , 2000 .

[13]  Elmar Pfeffermann,et al.  X-ray pn-CCDs on the XMM Newton Observatory , 2000, Astronomical Telescopes and Instrumentation.

[14]  Carlo Fiorini,et al.  Continuous charge restoration in semiconductor detectors by means of the gate-to-drain current of the integrated front-end JFET , 1999 .