Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients.

Purpose : We designed a water-based bolus device for radiation therapy in Kaposi’s sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods : We fashioned a polystyrene box and cut a hole in order to insert patient’s extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by 4.0 ∼ 4.4% to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume.

[1]  C. Hsieh,et al.  Accuracy of the convolution/superposition dose calculation algorithm at the condition of electron disequilibrium. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[2]  T. Chu,et al.  Dose compensation of the total body irradiation therapy. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[3]  J. Goldblum,et al.  Enzinger and Weiss's Soft Tissue Tumors , 2001 .

[4]  K. Jones The conversion of air splints to provide buildup bolus in the treatment of extremities with skin involvement. , 2000, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[5]  B. Wen,et al.  Dosimetric considerations of water-based bolus for irradiation of extremities. , 1998, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[6]  A. Garden,et al.  Water bolus for electron irradiation of the ear canal. , 1995, International journal of radiation oncology, biology, physics.

[7]  A. Brahme,et al.  Principles and Practice of Radiation Oncology , 1992 .

[8]  Z. Petrovich,et al.  Radiation therapy for acquired immunodeficiency syndrome-related Kaposi's sarcoma. , 1988, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[9]  Sung-Kon Kim,et al.  Physical Properties on Waxy Black Rice and Waxy Rice , 2002 .

[10]  K. Harrington,et al.  Response and cosmetic outcome of two fractionation regimens for AIDS-related Kaposi's sarcoma. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.