Development of an FPGA-based data acquisition module for small animal PET

We report on the design of a DAQ module for a small animal PET camera developed at our institutes. During the design an important guideline was to develop a system which is built up from strictly identical DAQ modules, and which has no built-in hardware limitation on the maximum number of modules. The developed DAQ module comprises of an LSO scintillator crystal block, a position sensitive PMT, analog signal conditioning circuits, a digitizer, an FPGA for digital signal processing and a communication module through which the collected data is sent to a cluster of computers for post processing and storage. Instead of implementing hardware coincidence detection between the modules we attach a precise time-stamp to each event in our design, and the coincidence is determined by the data collecting computers during the post processing. The digital CFD algorithm implemented in the FPGA gives a time resolution of 2 to 3 ns FWHM for real detector signals

[1]  John L. Humm,et al.  From PET detectors to PET scanners , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[2]  J. M. Rochelle,et al.  A custom mixed signal CMOS integrated circuit for high performance PET tomograph front-end applications , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[3]  Horst Halling,et al.  Coincidence detection by digital processing of free-running sampled pulses , 2002 .

[4]  C. Bohm,et al.  A flexible data acquisition module for high resolution PET camera , 2005, 14th IEEE-NPSS Real Time Conference, 2005..

[5]  Alberto Del Guerra,et al.  Detector development for a novel Positron Emission Mammography scanner based on YAP : Ce crystals , 2004 .

[6]  G. Brandenburg,et al.  The data acquisition system of ClearPET/spl trade/ Neuro - a small animal PET scanner , 2005, 14th IEEE-NPSS Real Time Conference, 2005..

[7]  P. O'Connor,et al.  The RatCAP conscious small animal PET tomograph , 2005, IEEE Symposium Conference Record Nuclear Science 2004..

[8]  T. Bukki,et al.  Ethernet Based Distributed Data Acquisition System for a Small Animal PET , 2005, IEEE Transactions on Nuclear Science.

[9]  Simon R. Cherry,et al.  Collection of scintillation light from small BGO crystals , 1995 .

[10]  G. Brandenburg,et al.  The data acquisition system of ClearPET neuro - a small animal PET scanner , 2006, IEEE Transactions on Nuclear Science.

[11]  Thomas K. Lewellen,et al.  Development of a data acquisition system for the MiCES small animal PET scanner , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[12]  J. M. Rochelle,et al.  Performance characteristics of a new generation of processing circuits for PET applications , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[13]  James F. Young,et al.  MicroPET: a high resolution PET scanner for imaging small animals , 1996, IEEE Nuclear Science Symposium Conference Record.