Spectral encoding of x-ray/optical relative delay.

We present a new technique for measuring the relative delay between a soft x-ray FEL pulse and an optical laser that indicates a sub 25 fs RMS measurement error. An ultra-short x-ray pulse photo-ionizes a semiconductor (Si(3)N(4)) membrane and changes the optical transmission. An optical continuum pulse with a temporally chirped bandwidth spanning 630 nm-710 nm interacts with the membrane such that the timing of the x-ray pulse can be determined from the onset of the spectral modulation of the transmitted optical pulse. This experiment demonstrates a nearly in situ single-shot measurement of the x-ray pulse arrival time relative to the ultra-short optical pulse.

[1]  J. Hajdu,et al.  Ultrafast Bond Softening in Bismuth: Mapping a Solid's Interatomic Potential with X-rays , 2007, Science.

[2]  T. N. Hansen,et al.  Clocking femtosecond X rays. , 2005, Physical review letters.

[3]  R. Treusch,et al.  Field-free molecular alignment probed by the free electron laser in Hamburg (FLASH) , 2009, 0902.0171.

[4]  Gianluca Geloni,et al.  Few-femtosecond timing at fourth-generation X-ray light sources , 2011 .

[5]  Thomas K. Allison,et al.  Controlling X-rays with light , 2010 .

[6]  P. Bucksbaum,et al.  Ionization and dissociation of H 2 in intense laser fields at 1.064 μm, 532 nm, and 355 nm , 1990 .

[7]  R. Henning,et al.  Imaging nonequilibrium atomic vibrations with x-ray diffuse scattering. , 2010, Physical review. B, Condensed matter and materials physics.

[8]  D. Ratner,et al.  First lasing and operation of an ångstrom-wavelength free-electron laser , 2010 .

[9]  J. Hajdu,et al.  Auger electron angular distribution of double core-hole states in the molecular reference frame. , 2010, Physical review letters.

[10]  W. A. Gillespie,et al.  Electro-optic time profile monitors for femtosecond electron bunches at the soft x-ray free-electron laser FLASH , 2009 .

[11]  Martin Beye,et al.  A femtosecond X-ray/optical cross-correlator , 2008 .

[12]  C. Bostedt,et al.  Femtosecond x-ray pulse length characterization at the Linac Coherent Light Source free-electron laser , 2011 .

[13]  Eugene T. Kennedy,et al.  Single-shot characterization of independent femtosecond extreme ultraviolet free electron and infrared laser pulses , 2007 .

[14]  D. Ratner,et al.  Femtosecond Operation of the LCLS for User Experiments , 2010 .

[15]  M. Drescher,et al.  Time-resolved ion spectrometry on xenon with the jitter-compensated soft x-ray pulses of a free-electron laser , 2009 .

[16]  J. Hajdu,et al.  Time-resolved pump-probe experiments at the LCLS. , 2010, Optics express.

[17]  R. Santra,et al.  X-ray-absorption near-edge structure of laser-dressed neon , 2008 .

[18]  Wei Li,et al.  Time-resolved pump-probe experiments beyond the jitter limitations at FLASH , 2009 .

[19]  R. Santra,et al.  Electromagnetically induced transparency for x rays. , 2007, Physical review letters.