A Method to Improve Experimental Validation of Finite‐Element Models of Long Bones

:  Finite-element (FE) simulations are extremely sensitive to boundary conditions, including the position of applied forces. This is particularly critical for FE models of bones, where the lack of a univocal reference system makes identifying the boundary conditions difficult. The aims of this work were to design a transducer (FP-transducer) to accurately determine the position of the resultant joint force during in vitro tests, and to assess its accuracy for future application in validating numerical models of long bones. A strain gauge-based transducer was designed to indirectly measure the position of the force applied to the long bones during in vitro tests, by measuring the reaction moments about two perpendicular axes, generated by the force applied. Validation tests were performed to quantify the intrinsic precision of the FP-transducer (by applying calibrated forces at known locations), and the overall accuracy when the FP-transducer was included in a typical set-up for long bone testing. The intrinsic accuracy of the FP-transducer when used to calculate the position of an offset force was satisfactory (0.66 mm). The overall accuracy of the FP-transducer in measuring the position of the applied force, when included in a typical set-up for long bone testing was 0.85 mm. In vitro validation of FE models of long bones may, therefore, be improved, thanks to a more accurate determination of the force application point.

[1]  M. Viceconti,et al.  Extracting clinically relevant data from finite element simulations. , 2005, Clinical biomechanics.

[2]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[3]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[4]  L Cristofolini,et al.  Mechanical validation of whole bone composite femur models. , 1996, Journal of biomechanics.

[5]  A. Perillo-Marcone,et al.  Assessment of the Effect of Mesh Density on the Material Property Discretisation Within QCT Based FE Models: A Practical Example Using the Implanted Proximal Tibia , 2003, Computer methods in biomechanics and biomedical engineering.

[6]  J H Keyak,et al.  Validation of an automated method of three-dimensional finite element modelling of bone. , 1993, Journal of biomedical engineering.

[7]  T. Ota,et al.  Fracture simulation of the femoral bone using the finite-element method: How a fracture initiates and proceeds , 1999, Journal of Bone and Mineral Metabolism.

[8]  S. Goldstein,et al.  Femoral strength is better predicted by finite element models than QCT and DXA. , 1999, Journal of biomechanics.

[9]  Angelo Cappello,et al.  Experimental errors in the application of photoelastic coatings on human femurs with uncemented hip stems , 1994 .

[10]  Luca Cristofolini,et al.  Biomechanical testing of the proximal femoral epiphysis: Intact and implanted condition , 2006 .

[11]  R. Darmana,et al.  Finite element analysis of the mechanical behavior of a scapula implanted with a glenoid prosthesis. , 2001, Clinical biomechanics.

[12]  H. Skinner,et al.  Prediction of femoral fracture load using automated finite element modeling. , 1997, Journal of biomechanics.

[13]  M Lengsfeld,et al.  Comparison of geometry-based and CT voxel-based finite element modelling and experimental validation. , 1998, Medical engineering & physics.

[14]  Marco Viceconti,et al.  Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy. , 2006, Journal of biomechanics.

[15]  W. Hayes,et al.  Cross-sectional geometry of Pecos Pueblo femora and tibiae--a biomechanical investigation: I. Method and general patterns of variation. , 1983, American journal of physical anthropology.

[16]  Ali Unuvar,et al.  Three-Component, strain Gage Based milling Dynamometer Design and manufacturing , 2001, Trans. SDPS.

[17]  L Cristofolini,et al.  In vitro stress shielding measurements can be affected by large errors. , 1999, The Journal of arthroplasty.

[18]  S. Stover,et al.  Development and validation of a series of three-dimensional finite element models of the equine metacarpus. , 1997, Journal of biomechanics.

[19]  H. Skinner,et al.  Effect of force direction on femoral fracture load for two types of loading conditions , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  F van Keulen,et al.  Development and experimental validation of a three-dimensional finite element model of the human scapula , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[21]  Michael A. Sutton,et al.  Towards the standardization of in vitro load transfer investigations of hip prostheses , 1999 .

[22]  M. Viceconti,et al.  A modified method for assigning material properties to FE models of bones. , 2008, Medical engineering & physics.

[23]  A. Cappello,et al.  Mechanical validation of whole bone composite tibia models. , 2000, Journal of biomechanics.

[24]  Barbara Reggiani,et al.  Finite-Element Modeling of Bones From CT Data: Sensitivity to Geometry and Material Uncertainties , 2006, IEEE Transactions on Biomedical Engineering.

[25]  Jamshid Tehranzadeh,et al.  Predicting Proximal Femoral Strength Using Structural Engineering Models , 2005, Clinical orthopaedics and related research.

[26]  Marco Viceconti,et al.  In vitro replication of spontaneous fractures of the proximal human femur. , 2007, Journal of biomechanics.