MINIMALLY INVASIVE ENDOSCOPIC AORTIC VALVE REPLACEMENT: OPERATIVE RESULTS.

To describe our endoscopic aortic valve replacement (E-AVR) technique and to evaluate its early results regardless of the type of prosthetic valve implanted and the patients' characteristics. From July 2013 to September 2018, 125 patients (76 males, mean age 68.8±10.9 years, mean EuroScore II 1.51±1.39) underwent isolated E-AVR due to a severe stenosis in 99 cases and insufficiency in 26 cases. The surgical access was a 3-4 cm working port in the second right intercostal space with no-rib spreading and three additional 5 mm mini-ports for the introduction of a 30-degree thoracoscope, the Chitwood clamp and the vent line. Cardiopulmonary by-pass (CPB) was achieved through a femoro-femoral cannulation. All patients successfully underwent E-AVR. Stended bioprostheses were implanted in 56 cases, Rapid Deployment and Sutureless valves in 23 and 46 cases respectively. Mean cross-clamping and CPB times were 87.5±22.1 and 126.1±28.4 minutes respectively and a significant difference between the types of prostheses was observed: 69.1±15.1 and 106.2±21.8 minutes (Sutureless) vs 93.2±15.1 and 135.5±21.8 minutes (Rapid Deployment) vs 100.6±17.2 and 138.9±21.9 minutes (Stented). Mean ventilation and ICU times and hospital stay were 10.9±39.3 hours, 45.9±58.4 hours and 8.3±9.3 days respectively. Thirty-day mortality was 0.8%. One patient (0.8%) needed a re-exploration for bleeding and three patients (2.4%) required a new permanent pacemaker implantation. No major neurologic events were observed. No paravalvular leakage was detected at discharge. E-AVR is associated with low mortality and few complications. Sutureless bioprostheses significantly reduce cross-clamping and CPB times. In dedicated Centers this approach may become a valid alternative to other minimally invasive techniques.

[1]  J. Maessen,et al.  Development of a high‐fidelity minimally invasive mitral valve surgery simulator , 2019, The Journal of thoracic and cardiovascular surgery.

[2]  Andrew S. Mugglin,et al.  Transcatheter Aortic‐Valve Replacement with a Self‐Expanding Valve in Low‐Risk Patients , 2019, The New England journal of medicine.

[3]  L. Salvador,et al.  Minimally invasive aortic valve replacement techniques using endoscopic surgery: ‘must dos’ and ‘preferences’ , 2018, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[4]  Qianzi Zhang,et al.  Isolated and concomitant minimally invasive minithoracotomy aortic valve surgery , 2017, The Journal of thoracic and cardiovascular surgery.

[5]  D. Shahian,et al.  The Society of Thoracic Surgeons Adult Cardiac Surgery Database: 2018 Update on Outcomes and Quality. , 2018, The Annals of thoracic surgery.

[6]  F. Roche,et al.  Closed chest human aortic valve removal and replacement: Technical feasibility and one year follow-up. , 2016, International journal of cardiology.

[7]  L. Salvador,et al.  Aortic valve replacement with a rapid deployment Edwards Intuity bioprosthesis using a completely video-guided approach. , 2015, Annals of Cardiothoracic Surgery.

[8]  B. Geršak,et al.  Sutureless aortic valve replacement: a systematic review and meta-analysis. , 2015, Annals of cardiothoracic surgery.

[9]  A. Miceli,et al.  Minimally invasive aortic valve surgery: state of the art and future directions. , 2015, Annals of cardiothoracic surgery.

[10]  Sean M. O'Brien,et al.  Contemporary real-world outcomes of surgical aortic valve replacement in 141,905 low-risk, intermediate-risk, and high-risk patients. , 2015, The Annals of thoracic surgery.

[11]  A. Rastan,et al.  Complications and conversions in minimally invasive aortic valve surgery. , 2015, Annals of cardiothoracic surgery.

[12]  M. Solinas,et al.  Minimally invasive aortic valve replacement using right minithoracotomy is associated with better outcomes than ministernotomy. , 2014, The Journal of thoracic and cardiovascular surgery.

[13]  Samer A M Nashef,et al.  EuroSCORE II. , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[14]  L. Thalib,et al.  Cross-clamp time is an independent predictor of mortality and morbidity in low- and high-risk cardiac patients. , 2011, International journal of surgery.

[15]  G. Merli,et al.  Cardiopulmonary bypass duration is an independent predictor of morbidity and mortality after cardiac surgery. , 2008, Journal of cardiothoracic and vascular anesthesia.

[16]  L. Svensson,et al.  "J" incision minimal-access valve operations. , 1998, The Annals of thoracic surgery.

[17]  S. Ray,et al.  Minimally invasive aortic valve replacement through a transverse sternotomy: a word of caution , 1998, Heart.

[18]  M. Mariani,et al.  Minimally invasive aortic valve replacement. , 1997, The Journal of thoracic and cardiovascular surgery.

[19]  D. Cosgrove,et al.  Minimally invasive approach for aortic valve operations. , 1996, The Annals of thoracic surgery.

[20]  A. Kumar,et al.  Aortic valve replacement through right thoracotomy. , 1993, Texas Heart Institute journal.