Narrow-Energy-Width CT Based on Multivoltage X-Ray Image Decomposition

A polychromatic X-ray beam causes the grey of the reconstructed image to depend on its position within a solid and the material being imaged. This factor makes quantitative measurements via computed tomography (CT) imaging very difficult. To obtain a narrow-energy-width reconstructed image, we propose a model to decompose multivoltage X-ray images into many narrow-energy-width X-ray images by utilizing the low frequency characteristics of X-ray scattering. It needs no change of hardware in the typical CT system. Solving the decomposition model, narrow-energy-width projections are obtained and it is used to reconstruct the image. A cylinder composed of aluminum and silicon is used in a verification experiment. Some of the reconstructed images could be regarded as real narrow-energy-width reconstructed images, which demonstrates the effectiveness of the proposed method.

[1]  陈平 Chen Ping,et al.  Multi-Spectrum Computed Tomography Imaging Method Based on Energy Spectrum Filtering Separation , 2014 .

[2]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[3]  Karl Stierstorfer,et al.  Photon counting CT at elevated X-ray tube currents: contrast stability, image noise and multi-energy performance , 2014, Medical Imaging.

[4]  P Zygmanski,et al.  Kilovoltage beam model for flat panel imaging system with bow-tie filter for scatter prediction and correction. , 2012, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[5]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[6]  Junguo Bian,et al.  Spectral CT Using Multiple Balanced K-Edge Filters , 2015, IEEE Transactions on Medical Imaging.

[7]  Wang Yixi,et al.  Data-constrained modelling of an anthracite coal physical structure with multi-spectrum synchrotron X-ray CT , 2013 .

[8]  Mitchell M Goodsitt,et al.  Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. , 2011, Medical physics.

[9]  Loick Verger,et al.  Characterizing the behavior of scattered radiation in multi-energy x-ray imaging , 2017 .

[10]  J. Fessler,et al.  Modelling the physics in the iterative reconstruction for transmission computed tomography , 2013, Physics in medicine and biology.

[11]  S Napel,et al.  Modeling of polychromatic attenuation using computed tomography reconstructed images. , 1999, Medical physics.

[12]  Jiaotong Wei,et al.  Improved contrast of materials based on multi-voltage images decomposition in X-ray CT , 2016 .

[13]  D. Tisseur,et al.  Scattering correction using continuously thickness-adapted kernels , 2016 .

[14]  S. Osher,et al.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM) , 2011, Inverse problems.

[15]  Richard A. Ketcham,et al.  Beam hardening correction for X-ray computed tomography of heterogeneous natural materials , 2014, Comput. Geosci..

[16]  Vladimir I Ivakhnenko A Novel Quasi-Linearization Method for CT Image Reconstruction in Scanners With a Multi-Energy Detector System , 2010, IEEE Transactions on Nuclear Science.

[17]  Peter York,et al.  Classification of microcrystalline celluloses via structures of individual particles measured by synchrotron radiation X-ray micro-computed tomography. , 2017, International journal of pharmaceutics.

[18]  Kai Mei,et al.  A Monte Carlo software bench for simulation of spectral k-edge CT imaging: Initial results. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[19]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[20]  G. Baldazzi,et al.  Development of a Multi-Energy CT for Small Animals: Characterization of the Quasi-Monochromatic X-Ray Source , 2009, IEEE Transactions on Nuclear Science.

[21]  R. Kruger,et al.  Scatter estimation for a digital radiographic system using convolution filtering. , 1987, Medical physics.

[22]  Lu Hong-nian Adaptive restraint algorithm to the scattered radiation of digital X-ray image , 2005 .

[23]  Jyh-Cheng Chen,et al.  A Single Scatter Model for X-ray CT Energy Spectrum Estimation and Polychromatic Reconstruction , 2015, IEEE Transactions on Medical Imaging.

[24]  Yves De Deene,et al.  On the validity of 3D polymer gel dosimetry: III. MRI-related error sources , 2013, Physics in medicine and biology.

[25]  Hans-Erik Nilsson,et al.  Material recognition with the Medipix photon counting colour X-ray system , 2004 .

[26]  Kentaro Uesugi,et al.  Quantitative evaluation of attenuation contrast of X-ray computed tomography images using monochromatized beams , 2005 .

[27]  W. Marsden I and J , 2012 .

[28]  T. Xiao,et al.  Quantification of soil aggregate microstructure on abandoned cropland during vegetative succession using synchrotron radiation-based micro-computed tomography , 2017 .

[29]  Iori Sumida,et al.  Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning , 2013, Journal of applied clinical medical physics.