Real‐time feedback for spatiotemporal field stabilization in MR systems

MR imaging and spectroscopy require a highly stable, uniform background field. The field stability is typically limited by hardware imperfections, external perturbations, or field fluctuations of physiological origin. The purpose of the present work is to address these issues by introducing spatiotemporal field stabilization based on real‐time sensing and feedback control.

[1]  K. Pruessmann,et al.  Spatiotemporal magnetic field monitoring for MR , 2008, Magnetic resonance in medicine.

[2]  Karl Johan Åström,et al.  PID Controllers: Theory, Design, and Tuning , 1995 .

[3]  Christoph Juchem,et al.  Magnetic field modeling with a set of individual localized coils. , 2010, Journal of magnetic resonance.

[4]  U. Klose In vivo proton spectroscopy in presence of eddy currents , 1990, Magnetic resonance in medicine.

[5]  Peter Styles,et al.  A novel field-frequency lock for a superconducting spectrometer , 1978 .

[6]  P. Luijten,et al.  Direct B0 field monitoring and real‐time B0 field updating in the human breast at 7 tesla , 2012, Magnetic resonance in medicine.

[7]  G. Glover,et al.  Respiration‐induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla , 2002, Magnetic resonance in medicine.

[8]  X. Hu,et al.  Reduction of signal fluctuation in functional MRI using navigator echoes , 1994, Magnetic resonance in medicine.

[9]  Jurek A Nordmeyer-Massner,et al.  NMR probes for measuring magnetic fields and field dynamics in MR systems , 2008, Magnetic resonance in medicine.

[10]  Richard Bowtell,et al.  Whole-brain susceptibility mapping at high field: A comparison of multiple- and single-orientation methods , 2010, NeuroImage.

[11]  Klaas Paul Pruessmann,et al.  Fast Higher-Order MR Image Reconstruction Using Singular-Vector Separation , 2012, IEEE Transactions on Medical Imaging.

[12]  J. Pauly,et al.  Isotropic diffusion‐weighted and spiral‐navigated interleaved EPI for routine imaging of acute stroke , 1997, Magnetic resonance in medicine.

[13]  Klaas P Pruessmann,et al.  A transmit/receive system for magnetic field monitoring of in vivo MRI , 2009, Magnetic resonance in medicine.

[14]  Lars Kasper,et al.  Gradient system characterization by impulse response measurements with a dynamic field camera , 2013, Magnetic resonance in medicine.

[15]  Christan G. Cabou Analytical Method for the Compensation of Eddy – Current Effects Induced by Pulsed Magnetic Field Gradients in NMR Systems , 2017 .

[16]  Matteo Pavan,et al.  Field camera measurements of gradient and shim impulse responses using frequency sweeps , 2014, Magnetic resonance in medicine.

[17]  C J Hardy,et al.  Real‐time interactive MRI on a conventional scanner , 1997, Magnetic resonance in medicine.

[18]  Michael Wyss,et al.  Feedback field control improves linewidths in in vivo magnetic resonance spectroscopy , 2014, Magnetic resonance in medicine.

[19]  Andrew G. Webb,et al.  Origin and reduction of motion and f0 artifacts in high resolution T2*-weighted magnetic resonance imaging: Application in Alzheimer's disease patients , 2010, NeuroImage.

[20]  H Bruder,et al.  Image reconstruction for echo planar imaging with nonequidistant k‐space sampling , 1992, Magnetic resonance in medicine.

[21]  R. S. Hinks,et al.  Real‐time shimming to compensate for respiration‐induced B0 fluctuations , 2007, Magnetic resonance in medicine.

[22]  J Hennig,et al.  Functional Imaging by I0‐ and T2* ‐parameter mapping using multi‐image EPI , 1998, Magnetic resonance in medicine.

[23]  J. Randall,et al.  Microwave Magnetrons , 1948, Nature.

[24]  Dardo Tomasi,et al.  Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[25]  Signe Johanna Vannesjo,et al.  Measurement and pre-emphasis of shim responses using frequency sweeps , 2011 .

[26]  E. Atalar,et al.  Monitoring and correcting spatio-temporal variations of the MR scanner’s static magnetic field , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[27]  Anthonie Hendrik Bergman,et al.  Optimization of eddy-current compensation☆ , 1990 .

[28]  J. Duyn,et al.  Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data , 2009, Magnetic resonance in medicine.

[29]  G. Glover,et al.  Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imaging , 2002, Magnetic resonance in medicine.

[30]  Manfred Morari,et al.  Model predictive control: Theory and practice - A survey , 1989, Autom..

[31]  Matteo Pavan,et al.  Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations , 2011, Magnetic resonance in medicine.

[32]  Yu-Chung N. Cheng,et al.  Susceptibility weighted imaging (SWI) , 2004, Zeitschrift fur medizinische Physik.