Three-phase inverter-connected DG-units and voltage unbalance

The increasing presence of single-phase distributed generators and unbalanced loads in the electric power system may lead to unbalance of the three phase voltages, resulting in increased losses and heating. The distribution network operators (DNOs) are increasingly being challenged to maintain the required power quality. To reduce voltage unbalance DNOs are seeking to connect larger DG units to the three phases instead of a single-phase connection. The three-phase connection can be realised by three single-phase inverters or by a three-phase inverter. Each inverter topology can be implemented with different control strategies. The control can be equiped with active power filtering functions which can improve the power quality. In this paper, the effect of connecting DG units by means of a three-phase connection instead of a single-phase connection on voltage unbalance is studied. Besides two commonly used control strategies, two other control strategies that combine DG and active power filtering functions are implemented and their effect on voltage unbalance is studied. The last two control strategies lead to the reduction of voltage unbalance such that the voltage requirements are maintained.

[1]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[2]  Jan Desmet,et al.  Analysis of the neutral conductor current in a three-phase supplied network with nonlinear single-phase loads , 2003 .

[3]  Lieven Vandevelde,et al.  Overview of PLL methods for distributed generation units , 2010, 45th International Universities Power Engineering Conference UPEC2010.

[4]  Peter Simon,et al.  Photovoltaikanlage zur dreiphasigen Einspeisung in ein elektrisches Energieversorgungsnetz , 2009 .

[5]  Lieven Vandevelde,et al.  Converter-connected distributed generation units with integrated harmonic voltage damping and harmonic current compensation function , 2009 .

[6]  Hirofumi Akagi Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribution Systems , 1997 .

[7]  Math Bollen IEEE Richard Harold Kaufmann Award Call for Nominations , 2002 .

[8]  M. Liserre,et al.  Independent synchronization and control of three phase grid converters , 2006, International Symposium on Power Electronics, Electrical Drives, Automation and Motion, 2006. SPEEDAM 2006..

[9]  J. H. Marks,et al.  Control techniques for active power filters , 2005 .

[10]  Sergio Busquets-Monge,et al.  Interfacing Renewable Energy Sources to the Utility Grid Using a Three-Level Inverter , 2006, IEEE Transactions on Industrial Electronics.

[11]  Jan T. Bialasiewicz,et al.  Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey , 2006, IEEE Transactions on Industrial Electronics.

[12]  Lieven Vandevelde,et al.  Overview of three-phase inverter topologies for distributed generation purposes , 2010 .

[13]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[14]  W. H. Kersting,et al.  Phase Frame Analysis of the Effects of Voltage Unbalance on Induction Machines , 1996, Proceedings of Rural Electric Power Conference.

[15]  Fei Wang,et al.  Reconfiguring grid-interfacing converters for power quality improvement , 2008 .

[16]  Jin-Woo Jung,et al.  A Three-Phase Four-Wire Inverter Control Technique for a Single Distributed Generation Unit in Island Mode , 2008, IEEE Transactions on Power Electronics.

[17]  Timothy C. Green,et al.  Control and filter design of three-phase inverters for high power quality grid connection , 2003 .

[18]  H. Akagi Determination of Needed FACTS Controllers That Increase Asset Utilization of Power Systems , 1997, IEEE Power Engineering Review.

[19]  Marco Liserre,et al.  PLL Algorithm for Power Generation Systems Robust to Grid Voltage Faults , 2006 .

[20]  Lieven Vandevelde,et al.  Fast harmonic simulation method for the analysis of network losses with converter-connected distributed generation , 2010 .

[21]  Lieven Vandevelde,et al.  Improving the voltage dip immunity of converter-connected distributed generation units , 2008 .

[22]  R. Belmans,et al.  Analysis of the neutral conductor current in a three phase supplied network with nonlinear single phase loads , 2001, IEMDC 2001. IEEE International Electric Machines and Drives Conference (Cat. No.01EX485).

[23]  H. A. Toliyat,et al.  Performance Analysis of a Three-Phase Induction Motor under Mixed Eccentricity Condition , 2002, IEEE Power Engineering Review.

[24]  L. Sainz,et al.  Study of neutral conductor current in three-phase networks with single-phase converters , 2006, IEEE Transactions on Power Delivery.

[25]  Zhiqian Bo,et al.  A nondifferential protection scheme for generator stator windings , 2001 .

[26]  V. Katic,et al.  Power Quality Problems Compensation With Universal Power Quality Conditioning System , 2007, IEEE Transactions on Power Delivery.

[27]  B. Han,et al.  Combined operation of unified power-quality conditioner with distributed generation , 2006, IEEE Transactions on Power Delivery.

[28]  Lieven Vandevelde,et al.  Neutral-point shifting and voltage unbalance due to single-phase DG units in low voltage distribution networks , 2009, 2009 IEEE Bucharest PowerTech.

[29]  Hong-Seok Song,et al.  Dual current control scheme for PWM converter under unbalanced input voltage conditions , 1999, IEEE Trans. Ind. Electron..

[30]  Fang Zheng Peng,et al.  Multilevel inverters: a survey of topologies, controls, and applications , 2002, IEEE Trans. Ind. Electron..

[31]  Reza Iravani,et al.  A unified dynamic model and control for the voltage-sourced converter under unbalanced grid conditions , 2006 .

[32]  Timothy C. Green,et al.  High-Quality Power Generation Through Distributed Control of a Power Park Microgrid , 2006, IEEE Transactions on Industrial Electronics.

[33]  Lieven Vandevelde,et al.  DC-bus voltage controllers for a three-phase voltage-source inverter for distributed generation , 2009 .

[34]  Ching-Yin Lee,et al.  Effects of unbalanced voltage on the operation performance of a three-phase induction motor , 1999 .