MRI-Guided Ventricular Tachycardia Ablation: Integration of Late Gadolinium-Enhanced 3D Scar in Patients With Implantable Cardioverter-Defibrillators

Background— Substrate-guided ablation of ventricular tachycardia (VT) in patients with implanted cardioverter-defibrillators (ICDs) relies on voltage mapping to define the scar and border zone. An integrated 3D scar reconstruction from late gadolinium enhancement (LGE) MRI could facilitate VT ablations. Methods and Results— Twenty-two patients with ICD underwent contrast-enhanced cardiac MRI with a specific absorption rate of <2.0 W/kg before VT ablation. Device interrogation demonstrated unchanged ICD parameters immediately before, after, or at 68±21 days follow-up (P>0.05). ICD imaging artifacts were most prominent in the anterior wall and allowed full and partial assessment of LGE in 9±4 and 12±3 of 17 segments, respectively. In 14 patients with LGE, a 3D scar model was reconstructed and successfully registered with the clinical mapping system (accuracy, 3.9±1.8 mm). Using receiver operating characteristic curves, bipolar and unipolar voltages of 1.49 and 4.46 mV correlated best with endocardial MRI scar. Scar visualization allowed the elimination of falsely low voltage recordings (suboptimal catheter contact) in 4.1±1.9% of <1.5-mV mapping points. Display of scar border zone allowed identification of excellent pace mapping sites, with only limited voltage mapping in 64% of patients. Viable endocardium of >2 mm resulted in >1.5-mV voltage recordings despite up to 63% transmural midmyocardial scar successfully ablated with MRI guidance. All successful ablation sites demonstrated LGE (transmurality, 68±26%) and were located within 10 mm of transition zones to 0% to 25% scar in 71%. Conclusions— Contrast-enhanced cardiac MRI can be safely performed in selected patients with ICDs and allows the integration of detailed 3D scar maps into clinical mapping systems, providing supplementary anatomic guidance to facilitate substrate-guided VT ablations.

[1]  Philip Sager,et al.  Identification of Reentry Circuit Sites During Catheter Mapping and Radiofrequency Ablation of Ventricular Tachycardia Late After Myocardial Infarction , 1993, Circulation.

[2]  Hugh Calkins,et al.  Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging. , 2006, Journal of the American College of Cardiology.

[3]  Emanuele Bertaglia,et al.  Integration of Three‐Dimensional Left Atrial Magnetic Resonance Images into a Real‐Time Electroanatomic Mapping System: Validation of a Registration Method , 2008, Pacing and clinical electrophysiology : PACE.

[4]  J. Oss,et al.  PROPHYLACTIC IMPLANTATION OF A DEFIBRILLATOR IN PATIENTS WITH MYOCARDIAL INFARCTION AND REDUCED EJECTION FRACTION , 2002 .

[5]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[6]  Freddy Odille,et al.  Electroanatomic characterization of post-infarct scars comparison with 3-dimensional myocardial scar reconstruction based on magnetic resonance imaging. , 2008, Journal of the American College of Cardiology.

[7]  H. Halperin,et al.  Clinical Utility and Safety of a Protocol for Noncardiac and Cardiac Magnetic Resonance Imaging of Patients With Permanent Pacemakers and Implantable-Cardioverter Defibrillators at 1.5 Tesla , 2006, Circulation.

[8]  Einar Heiberg,et al.  Automated quantification of myocardial infarction from MR images by accounting for partial volume effects: animal, phantom, and human study. , 2008, Radiology.

[9]  Benoit Desjardins,et al.  Infarct architecture and characteristics on delayed enhanced magnetic resonance imaging and electroanatomic mapping in patients with postinfarction ventricular arrhythmia. , 2009, Heart rhythm.

[10]  Benoit Desjardins,et al.  Delayed-enhanced magnetic resonance imaging in nonischemic cardiomyopathy: utility for identifying the ventricular arrhythmia substrate. , 2009, Journal of the American College of Cardiology.

[11]  Warren M. Jackman,et al.  Irrigated Radiofrequency Catheter Ablation Guided by Electroanatomic Mapping for Recurrent Ventricular Tachycardia After Myocardial Infarction: The Multicenter Thermocool Ventricular Tachycardia Ablation Trial , 2008, Circulation.

[12]  Mark E. Josephson,et al.  Clinical cardiac electrophysiology. , 2015, Clinical privilege white paper.

[13]  H. Schild,et al.  Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators. , 2009, Journal of the American College of Cardiology.

[14]  David O. Martin,et al.  Relationship Between Successful Ablation Sites and the Scar Border Zone Defined by Substrate Mapping for Ventricular Tachycardia Post‐Myocardial Infarction , 2005, Journal of cardiovascular electrophysiology.

[15]  Henry R. Halperin,et al.  Magnetic Resonance–Based Anatomical Analysis of Scar-Related Ventricular Tachycardia: Implications for Catheter Ablation , 2007, Circulation research.

[16]  Douglas L Packer,et al.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. , 2005, The New England journal of medicine.

[17]  F. Marchlinski,et al.  Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. , 2000, Circulation.

[18]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[19]  O. Simonetti,et al.  Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. , 1999, Circulation.

[20]  B. Schueler,et al.  MRI compatibility and visibility assessment of implantable medical devices , 1999, Journal of magnetic resonance imaging : JMRI.

[21]  Emanuel Kanal,et al.  Outcome of Magnetic Resonance Imaging (MRI) in Selected Patients with Implantable Cardioverter Defibrillators (ICDs) , 2005, Pacing and clinical electrophysiology : PACE.

[22]  E. McVeigh,et al.  Model of reentrant ventricular tachycardia based on infarct border zone geometry predicts reentrant circuit features as determined by activation mapping. , 2007, Heart rhythm.

[23]  O. Faris,et al.  Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients. , 2006, Circulation.

[24]  Raj Shekhar,et al.  Integration of three-dimensional scar maps for ventricular tachycardia ablation with positron emission tomography-computed tomography. , 2008, JACC. Cardiovascular imaging.

[25]  Multimodality fusion imaging using delayed-enhanced cardiac magnetic resonance imaging, computed tomography, positron emission tomography, and real-time intracardiac echocardiography to guide ventricular tachycardia ablation in implantable cardioverter-defibrillator patients. , 2009, Heart rhythm.