A review of ferroresonance in capacitive voltage transformer

Ferroresonance incidences in electrical power system have been commonly regarded as unexplained phenomenon, which is not critical for utility engineers. As a result, research conducted in this area is limited and the awareness on ferroresonance is relatively low among utility engineers. However, as the electrical system evolves, its complexity increases in line with the increasing risk of ferroresonance. As a result, this paper provides a consolidated review on the research conducted on ferroresonance to highlight its importance. This paper covers the fundamental inductor–capacitor pair for ferroresonance initiation and the modes of ferroresonance, followed by ferroresonance in capacitive voltage transformer (CVT), constituting its impact, initiation, and suppression techniques. The core focus in this paper is ferroresonance in CVT due to switching events, on which the documented literature is very scarce. © 2014 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.

[1]  M. A. Redfern,et al.  Characterization of ferroresonant modes in HV substation with CB grading capacitors , 2007 .

[2]  Hazlee Azil Illias,et al.  Lightning back flashover double circuit tripping pattern of 132 kV lines in Malaysia , 2013 .

[3]  M. Davarpanah,et al.  Compensation of CVT Increased Error and Its Impacts on Distance Relays , 2012, IEEE Transactions on Power Delivery.

[4]  R. Simpson,et al.  Subharmonic ferroresonance in an LCR circuit with hysteresis , 1997 .

[5]  M. Sanaye-Pasand,et al.  Comparison of performance of various ferroresonance suppressing methods in inductive and capacitive voltage transformers , 2006, 2006 IEEE Power India Conference.

[6]  D. L. Stuehm,et al.  Application of nonlinear dynamics and chaos to ferroresonance in distribution systems , 1994 .

[7]  M. Sanaye-Pasand,et al.  Impacts of Transformer Core Hysteresis Formation on Stability Domain of Ferroresonance Modes , 2009, IEEE Transactions on Power Delivery.

[8]  E. M. Lourenco,et al.  Modeling Ferroresonance Phenomena With a Flux-Current Jiles-Atherton Hysteresis Approach , 2013, IEEE Transactions on Magnetics.

[9]  R. Ramanujam,et al.  Isolated ferroresonant solutions in transmission lines in the same right-of-way , 2012 .

[10]  Suresh Vadhva,et al.  Review of ferroresonance in power distribution grids , 2011, 2011 IEEE International Conference on Information Reuse & Integration.

[11]  Kuo-Hsiung Tseng,et al.  Mitigating 161 kV electromagnetic potential transformers' ferroresonance with damping reactors in a gas-insulated switchgear , 2011 .

[12]  P. Shein,et al.  Voltage Transformer Ferroresonance in One 400 Kv Gis Substation , 1989, The Sixteenth Conference of Electrical and Electronics Engineers in Israel,.

[13]  H. A. Abyaneh,et al.  Improving capacitive voltage transformer response and its impact on distance relay performance , 2012, 20th Iranian Conference on Electrical Engineering (ICEE2012).

[14]  Darlan A. Fernandes,et al.  Coupling capacitor voltage transformer: A model for electromagnetic transient studies , 2007 .

[15]  Wei-Jen Lee,et al.  The jump phenomena , 2008, IEEE Industry Applications Magazine.

[16]  Serhat Seker,et al.  Continuous wavelet transform for ferroresonance phenomena in electric power systems , 2013 .

[17]  M. R. Iravani,et al.  Fast Ferroresonance Suppression of Coupling Capacitor Voltage Transformers , 2002, IEEE Power Engineering Review.

[18]  Ahmad Gholami,et al.  Investigation of performance of ferroresonance suppressing circuits in coupling capacitor voltage transformers , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[19]  Thomas J. Dionise,et al.  Transformer failure due to circuit breaker induced switching transients , 2010, Conference Record of 2010 Annual Pulp & Paper Industry Technical Conference.

[20]  Ping Liu,et al.  Theoretical Research on Ferroresonance in Neutral Grounded Power System , 2011 .

[21]  C. Banmongkol,et al.  Failure of Riser Pole Arrester due to Station Service Transformer Ferroresonance , 2007 .

[22]  W. W. L. Keerthipala,et al.  Improved simulation models for current and voltage transformers in relay studies , 1992 .

[23]  F. B. Amar,et al.  Study of the periodic ferroresonance in the electrical power networks by bifurcation diagrams , 2011 .

[24]  Alessandro Lo Schiavo,et al.  Analytical Approach to the Study of Injection-Locked Frequency Dividers , 2013, IEEE Transactions on Circuits and Systems I: Regular Papers.

[25]  D. John Yesuraj,et al.  Modeling and simulation of capacitor voltage transformer transients using PSCAD/EMTDC , 2011, 2011 IEEE Trondheim PowerTech.

[26]  K. Zimmerman,et al.  CVT transients revisited — Distance, directional overcurrent, and communications-assisted tripping concerns , 2012, 2012 65th Annual Conference for Protective Relay Engineers.

[27]  Davood Babazadeh,et al.  Mitigating ferroresonance in coupling capacitor voltage transformers with ferroresonance suppressing circuits , 2009, IEEE EUROCON 2009.

[28]  H A Toliyat,et al.  Impacts of Hysteresis and Magnetic Couplings on the Stability Domain of Ferroresonance in Asymmetric Three-Phase Three-Leg Transformers , 2011, IEEE Transactions on Energy Conversion.

[29]  Seyed Hamid Fathi,et al.  Harmonic study in electromagnetic voltage transformers , 2012, 2012 IEEE International Symposium on Industrial Electronics.

[30]  S. R. Naidu,et al.  Newton-Raphson approach for the analysis of ferroresonant circuits , 1997 .

[31]  N. Rahim,et al.  Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer(CVT) , 2011 .

[32]  Kruno Milicevic,et al.  Initiation of Characteristic Ferroresonance States Based on Flux Reflection Model , 2013, IEEE Transactions on Circuits and Systems II: Express Briefs.

[33]  C. Kieny Application of the bifurcation theory in studying and understanding the global behavior of a ferroresonant electric power circuit , 1991 .

[34]  Thomas J. Dionise,et al.  Medium-Voltage Switching Transient-Induced Potential Transformer Failures: Prediction, Measurement, and Practical Solutions , 2013, IEEE Transactions on Industry Applications.

[35]  Thomas J. Dionise,et al.  Vacuum Circuit Breaker Transients During Switching of an LMF Transformer , 2012 .

[36]  Gevork B. Gharehpetian,et al.  Ferroresonance suppression in power transformers using chaos theory , 2013 .

[37]  Daqing Hou,et al.  Capacitive voltage transformer: transient overreach concerns and solutions for distance relaying , 1996, Proceedings of 1996 Canadian Conference on Electrical and Computer Engineering.

[38]  A.H.A. Bakar,et al.  Investigation of Transient Performance of Capacitor Voltage Transformer , 2006, 2006 IEEE International Power and Energy Conference.

[39]  D. Giordano,et al.  Ferroresonance Analysis in LCR Circuits Including Rapidly Solidified Alloy Cores , 2009, IEEE Transactions on Magnetics.

[40]  A. J. Mazon,et al.  Behavioral patterns in voltage transformer for ferroresonance detection , 2012, 2012 16th IEEE Mediterranean Electrotechnical Conference.

[41]  R. Siregar,et al.  Investigation experience due to high number of CVTs failure (Part:1) , 2012, 2012 IEEE International Conference on Condition Monitoring and Diagnosis.

[42]  M. Sanaye-Pasand,et al.  Analysis and Suppression of the Coupling Capacitor Voltage Transformer Ferroresonance Phenomenon , 2009, IEEE Transactions on Power Delivery.

[43]  F. de Leon,et al.  A Comparative Study on $\pi$ and $T$ Equivalent Models for the Analysis of Transformer Ferroresonance , 2013, IEEE Transactions on Power Delivery.

[44]  M. Sanaye-Pasand,et al.  Minimizing the Impact of Transients of Capacitive Voltage Transformers on Distance Relay , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[45]  Ahmad Gholami,et al.  Chaotic oscillations control in the voltage transformer including nonlinear core loss model by a nonlinear robust adaptive controller , 2013 .

[46]  Ta-Peng Tsao,et al.  Analysis of ferroresonant overvoltages at Maanshan Nuclear Power Station in Taiwan , 2006 .