BEAM SPECIES FRACTION MEASUREMENT USING DOPPLER SHIFT METHOD WITH FUJIKURA FIBERSCOPE FOR IFMIF-EVEDA INJECTOR
暂无分享,去创建一个
To characterize high intensity ion beam in low energy beam transport line, diagnostics based on residual gas molecule excitation are commonly used. An example is CCD sensors for beam intensity, beam position and beam profile measurements. At CEA/Saclay with the SILHI injector, beam images transports from viewport to sensor have been performed with a fiberscope. Such technique will be used to transfer the beam images away from the irradiated zone of the IFMIF-EVEDA tunnel which requires using hardened radiation devices. Indeed, the (D,d) reaction, due to interaction of 140 mA-100 keV deuteron beam with vacuum pipes or scrapers, leads to high neutron and gamma ray flux. As a consequence, in addition to CID cameras for online beam positioning and shape measurements, a 20 m long Fujikura fiberscope has been selected to analyze species fraction using the Doppler shift method. Preliminary measurements have been performed with the SILHI beam to characterize the fiberscope. Its spatial resolution and transmission as well as a CCD sensor and fiberscope comparison are presented. Beam species fractions with and without the use of fiberscope are also reported.