Novel Instrument for Automated pK(a) Determination by Internal Standard Capillary Electrophoresis.

The internal standard capillary electrophoresis method (IS-CE) has been implemented in a novel sequential injection-capillary electrophoresis instrument for the high-throughput determination of acidity constants (pK(a)) regardless of aqueous solubility, number of pK(a) values, or structure. This instrument comprises a buffer creation system that automatically mixes within a few seconds four reagents for in situ creation of the separation electrolyte with a pH range of 2-13, ionic strength of 10-100 mM and organic solvent content from 0% to 40%. Combined with 1.2 kV/cm and a short effective length (15 cm to the UV detector) fast 20 s electrophoretic separations can be obtained. The low standard deviation of the replicates and the low variation compared to reference values show that this system can accurately determine acidity constants of drugs by IS-CE. A single pK(a) can be determined in 2 min and a set of 20 measurements in half an hour, allowing rapid, simple, and flexible determination of pK(a) values of pharmaceutical targets.

[1]  A. Avdeef,et al.  PH-metric log P 11. pKa determination of water-insoluble drugs in organic solvent-water mixtures. , 1999, Journal of pharmaceutical and biomedical analysis.

[2]  Li Di,et al.  Pharmaceutical profiling in drug discovery. , 2003, Drug discovery today.

[3]  John Comer,et al.  pH-Metric log P. 3. Glass electrode calibration in methanol-water, applied to pKa determination of water-insoluble substances , 1993 .

[4]  M. Breadmore,et al.  Identification of inorganic improvised explosive devices using sequential injection capillary electrophoresis and contactless conductivity detection. , 2011, Analytical chemistry.

[5]  Joel T. Smith,et al.  Determination of the ionization constants of weak electrolytes by capillary zone electrophoresis , 1992 .

[6]  Peter C Hauser,et al.  Rapid electrophoretic separations in short capillaries using contactless conductivity detection and a sequential injection analysis manifold for hydrodynamic sample loading. , 2006, The Analyst.

[7]  P. Boček,et al.  Effects of joule heat on the steady-state temperature profiles and the mean values of temperature in isotachophoresis , 1977 .

[8]  Rosanne M Guijt,et al.  On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks. , 2014, Journal of chromatography. A.

[9]  Joan M. Cabot,et al.  Determination of acidity constants of sparingly soluble drugs in aqueous solution by the internal standard capillary electrophoresis method , 2014, Electrophoresis.

[10]  Jetse Reijenga,et al.  Development of Methods for the Determination of pKa Values , 2013, Analytical chemistry insights.

[11]  M. Macka,et al.  Temperature profiles and heat dissipation in capillary electrophoresis. , 2006, Analytical chemistry.

[12]  G. Vigh,et al.  Isoelectric buffers, part 3: Determination of pKa and pI values of diamino sulfate carrier ampholytes by indirect UV‐detection capillary electrophoresis , 2005, Electrophoresis.

[13]  B. Lendl,et al.  Automated sample preparation and analysis using a sequential-injection-capillary electrophoresis (SI-CE) interface. , 2006, The Analyst.

[14]  E. Bosch,et al.  Critical evaluation of buffering solutions for pKa determination by capillary electrophoresis , 2008, Electrophoresis.

[15]  Joan M. Cabot,et al.  Determination of acidity constants by the capillary electrophoresis internal standard method. IV. Polyprotic compounds. , 2013, Journal of chromatography. A.

[16]  E. Bosch,et al.  Fast high-throughput method for the determination of acidity constants by capillary electrophoresis: I. Monoprotic weak acids and bases. , 2009, Journal of chromatography. A.

[17]  Karen A. Dehring,et al.  Determination of acid dissociation constants by capillary electrophoresis. , 2004, Journal of chromatography. A.

[18]  P. Kościelniak,et al.  Application of capillary electrophoresis in determination of acid dissociation constant values. , 2015, Journal of chromatography. A.

[19]  Johan Ulander,et al.  High-throughput pKa screening and prediction amenable for ADME profiling , 2006, Expert opinion on drug metabolism & toxicology.

[20]  M. Breadmore,et al.  On-line simultaneous and rapid separation of anions and cations from a single sample using dual-capillary sequential injection-capillary electrophoresis. , 2013, Analytica chimica acta.

[21]  W. T. Comer Perspectives in Drug Discovery , 2013 .

[22]  M. Breadmore,et al.  Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system. , 2014, Analytical chemistry.

[23]  Aliaa I. Shallan,et al.  Cost-effective three-dimensional printing of visibly transparent microchips within minutes. , 2014, Analytical chemistry.

[24]  Philippe Carrière On a three-dimensional implementation of the baker’s transformation , 2007 .

[25]  Dragana Mutavdžić Pavlović,et al.  Determination of pKa values of active pharmaceutical ingredients , 2007 .

[26]  Franco Lombardo,et al.  Measurement of dissociation constants (pKa values) of organic compounds by multiplexed capillary electrophoresis using aqueous and cosolvent buffers. , 2008, Journal of pharmaceutical sciences.