Ergonomic risk associated with assisting in minimally invasive surgery

BackgroundGiven the physical risks associated with performing laparoscopic surgery, ergonomics to date has focused on the primary minimally invasive surgeon. Similar studies have not extended to other operating room staff. Simulation of the assistant’s role as camera holder and retractor during a Nissen fundoplication allowed investigation of the ergonomic risks involved in these tasks.MethodsSeven subjects performed camera navigation and retraction tasks using a box trainer on an operating room table that simulated an adult patient in low lithotomy position. Each subject stood on force plates at the simulated patient’s left side. A laparoscope was introduced through a port into the training box with four 2-cm circles as rear-panel targets located in relation to the assistant as distal superior, proximal superior, distal inferior, and proximal inferior target effects. The subjects held the camera with their left hand, pointing it at a target. The task was to match the target to a circle overlaid on the monitor. Simultaneously, a grasper in the right hand grasped and pulled a panel-attached band. A minute signal moved the subject to the next target. Each trial had three four-target repetitions (phase effect). The subjects performed two separate trials: one while holding the camera from the top and one while holding it from the bottom (grip effect). A 4 × 3 × 2 (target × phase × grip) repeated-measures design provided statistics. Dividing the left force-plate vertical ground reaction forces (VGRF) by the total VGRF from both plates provided a weight-loading ratio (WLR).ResultsThe WLR significantly increased (p < 0.005) with proximal targets (2 by 80% and 4 by 79%). The WLR decreased 75%, 74%, and 71% over time. No difference existed between the grip strategies (grip effect, p > 0.5).ConclusionsA high-risk ergonomic situation is created by the assistant’s left or caudal leg disproportionately bearing 70–80% of body weight over time. A distance increase between the camera head location and the camera holder increases ergonomic risk. The phase effect was interpreted as a compensatory rebalancing to reduce ergonomic risk. Ergonomic solutions minimizing ergonomic risks associated with laparoscopic assistance should be considered.

[1]  François Prince,et al.  Postural control during laparoscopic surgical tasks. , 2007, American journal of surgery.

[2]  W. D. Smith,et al.  An ergonomic study of the optimum operating table height for laparoscopic surgery , 2002, Surgical Endoscopy And Other Interventional Techniques.

[3]  A. Cuschieri,et al.  Ergonomic principles of task alignment, visual display, and direction of execution of laparoscopic bowel suturing , 2002, Surgical Endoscopy And Other Interventional Techniques.

[4]  C G Drury,et al.  Posture, Postural Discomfort, and Performance , 1985, Human factors.

[5]  T. G. Frank,et al.  Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing , 2001, Surgical Endoscopy.

[6]  M. Moont,et al.  In-line vs pistol-grip handles in a laparoscopic simulator , 2003, Surgical Endoscopy And Other Interventional Techniques.

[7]  D. Meijer,et al.  Evaluation of the usability of two types of image display systems, during laparoscopy , 2001, Surgical Endoscopy.

[8]  Warren D. Smith,et al.  Ergonomic problems associated with laparoscopic surgery , 1999, Surgical Endoscopy.

[9]  M.A. van Veelen,et al.  Improved physical ergonomics of laparoscopic surgery , 2004, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[10]  A. Cuschieri,et al.  Rocker handle for endoscopic needle drivers , 1999, Surgical Endoscopy.

[11]  W. B. Seales,et al.  Assessing Mental Workload During Laparoscopic Surgery , 2005, Surgical innovation.

[12]  J. Jakimowicz,et al.  Ergonomic problems encountered by the medical team related to products used for minimally invasive surgery , 2003, Surgical Endoscopy And Other Interventional Techniques.

[13]  Adrian Park,et al.  Methodological Infrastructure in Surgical Ergonomics: A Review of Tasks, Models, and Measurement Systems , 2007, Surgical innovation.

[14]  Postural instability does not necessarily correlate to poor performance: case in point , 2007, Surgical Endoscopy.

[15]  P van Wely,et al.  Design and disease. , 1970, Applied ergonomics.

[16]  Monitor height affects surgeons' stress level and performance on minimally invasive surgery tasks. , 2005, Studies in health technology and informatics.

[17]  A. Cuschieri,et al.  Comparison of orthodox versus off-optical axis endoscopic manipulations , 2001, Surgical Endoscopy And Other Interventional Techniques.

[18]  R. Riener,et al.  Acquisition of arm and instrument movements during laparoscopic interventions , 2003, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[19]  C. Giebmeyer,et al.  Ergonomic aspects of five different types of laparoscopic instrument handles under dynamic conditions with respect to specific laparoscopic tasks: An electromyographic-based study , 2004, Surgical Endoscopy And Other Interventional Techniques.

[20]  Adrian E. Park,et al.  Development of a more robust tool for postural stability analysis of laparoscopic surgeons , 2007, Surgical Endoscopy.

[21]  R H M Goossens,et al.  Assessment of the ergonomically optimal operating surface height for laparoscopic surgery. , 2002, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[22]  M Patkin,et al.  Ergonomics, engineering and surgery of endosurgical dissection. , 1995, Journal of the Royal College of Surgeons of Edinburgh.

[23]  A. Cuschieri,et al.  Minimal access surgery (MAS)-related surgeon morbidity syndromes , 2005, Surgical Endoscopy And Other Interventional Techniques.

[24]  David A. Winter,et al.  Human balance and posture control during standing and walking , 1995 .

[25]  C. A. Fischer,et al.  Surgeon workload and motion efficiency with robot and human laparoscopic camera control , 2001, Surgical Endoscopy.

[26]  R. Berguer,et al.  A comparison of surgeons' posture during laparoscopic and open surgical procedures , 1997, Surgical Endoscopy.

[27]  A. Cuschieri,et al.  Effect of intracorporeal-extracorporeal instrument length ratio on endoscopic task performance and surgeon movements. , 2000, Archives of surgery.

[28]  A. E. Park,et al.  The effect of using laparoscopic instruments on muscle activation patterns during minimally invasive surgical training procedures , 2003, Surgical Endoscopy And Other Interventional Techniques.

[29]  I. Kant,et al.  A survey of static and dynamic work postures of operating room staff , 1992, International archives of occupational and environmental health.

[30]  Changes in postural mechanics associated with different types of minimally invasive surgical training exercises , 2003, Surgical Endoscopy And Other Interventional Techniques.

[31]  Alfred Cuschieri,et al.  Differences between Experts and Trainees in the Motion Pattern of the Dominant Upper Limb during Intracorporeal Endoscopic Knotting , 2000, Digestive Surgery.

[32]  W M Keyserling A computer-aided system to evaluate postural stress in the workplace. , 1986, American Industrial Hygiene Association journal.

[33]  J. Brøgger,et al.  In-line versus pistol-grip handles in a laparoscopic simulators , 2002, Surgical Endoscopy And Other Interventional Techniques.

[34]  A. J. Hodgson,et al.  Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery , 2009, Surgical Endoscopy.

[35]  C. J. Snijders,et al.  Improvement of the laparoscopic needle holder based on new ergonomic guidelines , 2003, Surgical Endoscopy And Other Interventional Techniques.

[36]  William H Gage,et al.  Kinematic and kinetic validity of the inverted pendulum model in quiet standing. , 2004, Gait & posture.

[37]  J.W. HUBER,et al.  The effects of different viewing conditions on performance in simulated minimal access surgery , 2003, Ergonomics.

[38]  E N Corlett,et al.  A technique for assessing postural discomfort. , 1976, Ergonomics.

[39]  A. Cuschieri,et al.  Comparison of direct vision and electronic two‐ and three‐dimensional display systems on surgical task efficiency in endoscopic surgery , 1995, The British journal of surgery.

[40]  Ara Darzi,et al.  The relationship between motion analysis and surgical technical assessments. , 2002, American journal of surgery.