Lung Cancer Screening Using Clinical Photon-Counting Detector Computed Tomography and Energy-Integrating-Detector Computed Tomography: A Prospective Patient Study

Objective To evaluate the diagnostic quality of photon-counting detector (PCD) computed tomography (CT) in patients undergoing lung cancer screening compared with conventional energy-integrating detector (EID) CT in a prospective multireader study. Materials Patients undergoing lung cancer screening with conventional EID-CT were prospectively enrolled and scanned on a PCD-CT system using similar automatic exposure control settings and reconstruction kernels. Three thoracic radiologists blinded to CT system compared PCD-CT and EID-CT images and scored examinations using a 5-point Likert comparison score (−2 [left image is worse] to +2 [left image is better]) for artifacts, sharpness, image noise, diagnostic image quality, emphysema visualization, and lung nodule evaluation focusing on the border. Post hoc correction of Likert scores was performed such that they reflected PCD-CT performance in comparison to EID-CT. A nonreader radiologist measured objective image noise. Results Thirty-three patients (mean, 66.9 ± 5.6 years; 11 female; body mass index; 30.1 ± 5.1 kg/m2) were enrolled. Mean volume CT dose index for PCD-CT was lower (0.61 ± 0.21 vs 0.73 ± 0.22; P < 0.001). Pooled reader results showed significant differences between imaging modalities for all comparative rankings (P < 0.001), with PCD-CT favored for sharpness, image noise, image quality, and emphysema visualization and lung nodule border, but not artifacts. Photon-counting detector CT had significantly lower image noise (74.4 ± 10.5 HU vs 80.1 ± 8.6 HU; P = 0.048). Conclusions Photon-counting detector CT with similar acquisition and reconstruction settings demonstrated improved image quality and less noise despite lower radiation dose, with improved ability to depict pulmonary emphysema and lung nodule borders compared with EID-CT at low-dose lung cancer CT screening.

[1]  T. Flohr,et al.  First Clinical Photon-counting Detector CT System: Technical Evaluation. , 2021, Radiology.

[2]  H. Alkadhi,et al.  First Performance Evaluation of an Artificial Intelligence-Based Computer-Aided Detection System for Pulmonary Nodule Evaluation in Dual-Source Photon-Counting Detector CT at Different Low-Dose Levels. , 2021, Investigative radiology.

[3]  Jeffrey F. Marsh,et al.  Full field-of-view, high-resolution, photon-counting detector CT: Technical assessment and initial patient experience , 2021, Physics in medicine and biology.

[4]  F. Becce,et al.  Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study , 2021, European Radiology.

[5]  L. Boussel,et al.  Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system. , 2021, Diagnostic and interventional imaging.

[6]  E. Kazerooni,et al.  Lung-RADS Version 1.1: Challenges and a Look Ahead, From the AJR Special Series on Radiology Reporting and Data Systems. , 2021, AJR. American journal of roentgenology.

[7]  T. Flohr,et al.  Photon-counting CT review. , 2020, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[8]  Rebecca M. Lindell,et al.  Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels. , 2020, Radiology.

[9]  Harry J de Koning,et al.  Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial. , 2020, The New England journal of medicine.

[10]  H. Kauczor,et al.  Lung cancer mortality reduction by LDCT screening—Results from the randomized German LUSI trial , 2019, International journal of cancer.

[11]  C. McCollough,et al.  Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter. , 2019, Investigative radiology.

[12]  R. Booton,et al.  CT screening for lung cancer: Are we ready to implement in Europe? , 2019, Lung cancer.

[13]  Shuai Leng,et al.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. , 2019, Radiographics : a review publication of the Radiological Society of North America, Inc.

[14]  G. Corrao,et al.  Prolonged lung cancer screening reduced 10-year mortality in the MILD trial: new confirmation of lung cancer screening efficacy , 2019, Annals of oncology : official journal of the European Society for Medical Oncology.

[15]  Chi Wan Koo,et al.  High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography , 2019, Investigative radiology.

[16]  C. McCollough,et al.  150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology , 2018, Investigative Radiology.

[17]  Wei Zhou,et al.  150-&mgr;m Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images , 2018, Investigative radiology.

[18]  Stefan Ulzheimer,et al.  Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans. , 2017, Radiology.

[19]  A. Bankier,et al.  Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017. , 2017, Radiology.

[20]  Steffen Kappler,et al.  Low-dose lung cancer screening with photon-counting CT: a feasibility study , 2017, Physics in medicine and biology.

[21]  Katharina Hahn,et al.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system , 2016, Journal of medical imaging.

[22]  Felix G. Meinel,et al.  Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT. , 2016, European journal of radiology.

[23]  Asger Dirksen,et al.  Visual assessment of early emphysema and interstitial abnormalities on CT is useful in lung cancer risk analysis , 2016, European Radiology.

[24]  Mitsuru Ikeda,et al.  Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis. , 2015, European journal of radiology.

[25]  Michael F. McNitt-Gray,et al.  ACR–STR Practice Parameter for the Performance and Reporting of Lung Cancer Screening Thoracic Computed Tomography (CT): 2014 (Resolution 4)* , 2014, Journal of thoracic imaging.

[26]  Shuai Leng,et al.  Electronic noise in CT detectors: Impact on image noise and artifacts. , 2013, AJR. American journal of roentgenology.

[27]  C. Gatsonis,et al.  Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening , 2012 .

[28]  D. Lynch,et al.  The National Lung Screening Trial: overview and study design. , 2011, Radiology.

[29]  E. S. Amis,et al.  CT screening. , 2003, Radiology.