Comparison of the Effects of Proximal Humeral Internal Locking System (PHILOS) Alone and PHILOS Combined with Fibular Allograft in the Treatment of Neer Three‐ or Four‐part Proximal Humerus Fractures in the Elderly
暂无分享,去创建一个
Chun-zhi Jiang | B. Liang | Lei Yang | Gang-rui Wang | Sheng-nai Zheng | Qiang Wang | Lei Zhao | Yimin Qi
[1] N. Jain,et al. Minimal Clinically Important Difference of Shoulder Outcome Measures and Diagnoses: A Systematic Review. , 2019, American journal of physical medicine & rehabilitation.
[2] J. W. Kim,et al. Outcomes of locking plate fixation with fibular allograft augmentation for proximal humeral fractures in osteoporotic patients: COMPARISON WITH LOCKING PLATE FIXATION ALONE , 2019, The bone & joint journal.
[3] J. Argenson,et al. Three- and four-part displaced proximal humeral fractures in patients older than 70 years: reverse shoulder arthroplasty or nonsurgical treatment? , 2019, Journal of shoulder and elbow surgery.
[4] A. Tennant,et al. Revisiting the disabilities of the arm, shoulder and hand (DASH) and QuickDASH in rheumatoid arthritis , 2019, BMC Musculoskeletal Disorders.
[5] V. Mattila,et al. Nordic Innovative Trials to Evaluate osteoPorotic Fractures (NITEP) Collaboration: The Nordic DeltaCon Trial protocol—non-operative treatment versus reversed total shoulder arthroplasty in patients 65 years of age and older with a displaced proximal humerus fracture: a prospective, randomised contro , 2019, BMJ Open.
[6] C. Sommer,et al. Long-term follow-up after MIPO Philos plating for proximal humerus fractures , 2018, Archives of Orthopaedic and Trauma Surgery.
[7] N. Balasubramanian,et al. Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients , 2018, Malaysian orthopaedic journal.
[8] P. Smerdely,et al. Incidence and outcomes of humeral fractures in the older person , 2018, Osteoporosis International.
[9] S. Bellringer,et al. ‘Modern' distal femoral locking plates allow safe, early weight‐bearing with a high rate of union and low rate of failure: FIVE‐YEAR EXPERIENCE FROM A UNITED KINGDOM MAJOR TRAUMA CENTRE , 2017, The bone & joint journal.
[10] Kursat Teker,et al. Minimally invasive plate osteosynthesis with PHILOS plate for proximal humerus fractures , 2016, Acta orthopaedica et traumatologica turcica.
[11] M. Bhandari,et al. Operative vs non-operative management of displaced proximal humeral fractures in the elderly: A systematic review and meta-analysis of randomized controlled trials. , 2015, World journal of orthopedics.
[12] C. Fang,et al. Minimally Invasive Plate Osteosynthesis for Proximal Humeral Fractures , 2015, Journal of orthopaedic surgery.
[13] Xiangdang Liang,et al. Clinical outcomes of allograft with locking compression plates for elderly four-part proximal humerus fractures , 2015, Journal of Orthopaedic Surgery and Research.
[14] C. Theisen,et al. How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data. , 2015, Injury.
[15] A. Desai,et al. Management of proximal humerus fractures in adults. , 2014, World journal of orthopedics.
[16] Peixun Zhang,et al. Effect of Calcar Screw Use in Surgical Neck Fractures of the Proximal Humerus With Unstable Medial Support: A Biomechanical Study , 2014, Journal of orthopaedic trauma.
[17] C. Sommer,et al. A prospective analysis of the functional and radiological outcomes of minimally invasive plating in proximal humerus fractures. , 2013, Injury.
[18] D. Kovacevic,et al. Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate? , 2013, BMC Musculoskeletal Disorders.
[19] M. Innocenti,et al. Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus. , 2012, Injury.
[20] Chunxi Yang,et al. Internal fixation versus shoulder hemiarthroplasty for displaced 4-part proximal humeral fractures in elderly patients. , 2012, Orthopedics.
[21] J. Zuckerman,et al. Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. , 2012, Journal of shoulder and elbow surgery.
[22] D. Lorich,et al. Locked Plating of the Proximal Humerus Using an Endosteal Implant , 2012, Journal of orthopaedic trauma.
[23] J. Bellemans,et al. Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus. , 2012, Injury.
[24] C. Theisen,et al. Complex fractures of the proximal humerus in the elderly—outcome and complications after locking plate fixation , 2012, MUSCULOSKELETAL SURGERY.
[25] C. Kammerlander,et al. Predicting failure after surgical fixation of proximal humerus fractures. , 2011, Injury.
[26] G. Osterhoff,et al. The calcar screw in angular stable plate fixation of proximal humeral fractures - a case study , 2011, Journal of orthopaedic surgery and research.
[27] S. Ponzer,et al. Internal fixation versus nonoperative treatment of displaced 3-part proximal humeral fractures in elderly patients: a randomized controlled trial. , 2011, Journal of shoulder and elbow surgery.
[28] D. Lorich,et al. Endosteal Strut Augment Reduces Complications Associated With Proximal Humeral Locking Plates , 2011, Clinical Orthopaedics and Related Research.
[29] B. Feeley,et al. A systematic review of locking plate fixation of proximal humerus fractures. , 2011, Injury.
[30] R. Zdero,et al. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. , 2010, The Journal of trauma.
[31] P. Clavert,et al. Pitfalls and complications with locking plate for proximal humerus fracture. , 2010, Journal of shoulder and elbow surgery.
[32] L. Munuera,et al. Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: the role of implant stiffness. , 2010, Clinical Biomechanics.
[33] J. Abboud,et al. Use of locking plates in the treatment of proximal humerus fractures. , 2010, Journal of shoulder and elbow surgery.
[34] Sang-Jin Shin,et al. Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures , 2009, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.
[35] Charles S Neer,et al. Four-segment classification of proximal humeral fractures: purpose and reliable use. , 2002, Journal of shoulder and elbow surgery.
[36] R Melzack,et al. Measurement of pain. , 1999, The Surgical clinics of North America.
[37] V C Mow,et al. A standardized method for the assessment of shoulder function. , 1994, Journal of shoulder and elbow surgery.