Wireless implantable passive strain sensor: design, fabrication and characterization

This work presents a new passive sensor concept for monitoring the deformation of orthopedic implants. The novel sensing principle of the WIPSS (wireless implantable passive strain sensor) is based on a hydro-mechanical amplification effect. The WIPSS is entirely made from biocompatible PMMA and consists of a microchannel attached to a reservoir, which is filled with an incompressible fluid. As the reservoir is exposed to strain, its volume changes and consequently the fill level inside the microchannel varies. The wireless detection of the microchannel's strain-dependent fill level is based on ultrasound. The WIPSS' sensing principle is proved by finite-element simulations and the reservoir's design is optimized toward maximum volume change, in order to achieve high sensitivity. A fabrication process for WIPSS sensor devices entirely made from PMMA is presented. The obtained measurement results confirmed the sensor's functionality and showed very good agreement with the obtained results of the conducted FE simulations regarding the sensor's sensitivity. A strain resolution of 1.7 ± 0.2 × 10−5 was achieved. Further, the determination of the cross-sensitivity to temperature and strains applied out of the sensing direction is presented. The response to dynamic inputs (0.1–5 Hz) has been measured and showed decreasing sensor output with increasing frequency. Test structures of the sensor device allow the application of a signal bandwidth up to 1 Hz. Therefore, the proposed sensor concept of the WIPSS presents a promising new sensor system for static in vivo strain monitoring of orthopedic implants. In combination with the developed ultrasound-based read-out method, this new sensor system offers the potential of wireless sensor read-out with medical ultrasound scanners, which are commercially available.

[1]  R. Nuzzo,et al.  A method for filling complex polymeric microfluidic devices and arrays. , 2001, Analytical chemistry.

[2]  S. Nagasawa,et al.  A Highly Sensitive Strain Sensor Using Surface Acoustic Wave and Its Evaluation for Wireless Battery-less Sensor Network , 2007, 2007 IEEE Sensors.

[3]  Sérgio Francisco Pichorim,et al.  Biotelemetric passive sensor injected within tendon for strain and elasticity measurement , 2006, IEEE Transactions on Biomedical Engineering.

[4]  K. E. Tanner,et al.  Strain measurement in biomechanics , 1992 .

[6]  R. Puers,et al.  Monitoring orthopaedic implants using active telemetry , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  J. Szivek,et al.  Long-term measurement of bone strain in vivo: the rat tibia. , 2001, Journal of biomedical materials research.

[8]  Christofer Hierold,et al.  SOLVENT ASSISTED BONDING OF POLYMETHYLMETHACRYLATE: CHARACTERIZATION USING THE RESPONSE SURFACE METHODOLOGY , 2009 .

[9]  V. Kalinin,et al.  Passive wireless strain and temperature sensors based on SAW devices , 2004, Proceedings. 2004 IEEE Radio and Wireless Conference (IEEE Cat. No.04TH8746).

[10]  N. Rydell Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. , 1966, Acta orthopaedica Scandinavica.

[11]  A H Burstein,et al.  Telemetering in vivo loads from nail plate implants. , 1982, Journal of biomechanics.

[12]  I. Abe,et al.  Plated and Intact Femur Strains in Fracture Fixation Using Fiber Bragg Gratings and Strain Gauges , 2007 .

[13]  David W. Hoeppner,et al.  Fretting in orthopaedic implants: A review , 1994 .

[14]  S.F. Pichorim,et al.  A Novel Method to Read Remotely Resonant Passive Sensors in Biotelemetric Systems , 2008, IEEE Sensors Journal.

[15]  Shawn M. Walsh,et al.  Wireless, passive, resonant-circuit, inductively coupled, inductive strain sensor , 2002 .

[16]  O Paiva,et al.  Concept, design and fabrication of smart orthopedic implants. , 2000, Medical engineering & physics.

[17]  L. Lanyon,et al.  In vivo strain measurements from bone and prosthesis following total hip replacement. An experimental study in sheep. , 1981, The Journal of bone and joint surgery. American volume.

[18]  P. Walker,et al.  Forces and moments telemetered from two distal femoral replacements during various activities. , 2001, Journal of biomechanics.

[19]  John A Szivek,et al.  In vivo strain measurements from hardware and lamina during spine fusion. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[20]  T. Meydan,et al.  Enhancement of magnetorestrictive properties of amorphous ribbons for a biomedical application , 1997 .

[21]  Felix Gattiker,et al.  Drahtloser, implantierbarer und passiver Dehnungssensor (Wireless Implantable Passive Strain Sensor) , 2008 .

[22]  Buddy D. Ratner,et al.  Biomaterials Science: An Introduction to Materials in Medicine , 1996 .

[23]  Jay R. Lieberman,et al.  Bone Regeneration and Repair , 2005 .

[24]  B. A. Jordan,et al.  The Corrosion Fatigue Properties of Surgical Implant Materials. Third Progress Report—May 1973 , 1978 .

[25]  Felix Gattiker,et al.  Novel Ultrasound Read-Out for a Wireless Implantable Passive Strain Sensor (WIPSS) , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[26]  Jay R. Lieberman,et al.  Bone regeneration and repair : biology and clinical applications , 2005 .

[27]  Bernhard Weisse,et al.  Magnetoelastic Strain Sensor for Optimized Assessment of Bone Fracture Fixation , 2009, IEEE Sensors Journal.

[28]  F. Umbrecht,et al.  A wireless implantable passive strain sensor system , 2005, IEEE Sensors, 2005..

[29]  Antonius Rohlmann,et al.  Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month. , 2008, Clinical biomechanics.

[30]  F. Umbrecht,et al.  Novel Ultrasound Read-Out for a Wireless Implantable Passive Strain Sensor (WIPSS) , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[31]  P. Komi,et al.  Achilles tendon loading during walking: application of a novel optic fiber technique , 1998, European Journal of Applied Physiology and Occupational Physiology.

[32]  Christian M. Puttlitz,et al.  Bio-implantable passive on-chip RF-MEMS strain sensing resonators for orthopaedic applications , 2008 .

[33]  Urs Sennhauser,et al.  Wireless Implantable Passive Strain Sensor , 2007 .

[34]  C. Geffre,et al.  Sensate scaffolds coupled to telemetry can monitor in vivo loading from within a joint over extended periods of time. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[35]  E Schneider,et al.  Loads acting in an intramedullary nail during fracture healing in the human femur. , 2001, Journal of biomechanics.