Mass Spectrometry-Based Charge Heterogeneity Characterization of Therapeutic mAbs with Imaged Capillary Isoelectric Focusing and Ion-Exchange Chromatography as Separation Techniques.

Imaged capillary isoelectric focusing (icIEF) and ion-exchange chromatography (IEX) are two essential techniques that are routinely used for charge variant analysis of therapeutic monoclonal antibodies (mAbs) during their development and in quality control. These two techniques that separate mAb charge variants based on different mechanisms and IEX have been developed as front-end separation techniques for online mass spectrometry (MS) detection, which is robust for intact protein identification. Recently, an innovative, coupled icIEF-MS technology has been constructed for protein charge variant analysis in our laboratory. In this study, icIEF-MS developed and strong cation exchange (SCX)-MS were optimized for charge heterogeneity characterization of a diverse of mAbs and their results were compared based on methodological validation. It was found that icIEF-MS outperformed SCX-MS in this study by demonstrating outstanding sensitivity, low carryover effect, accurate protein identification, and higher separation resolution although SCX-MS contributed to higher analysis throughput. Ultimately, integrating our novel icIEF-HRMS analysis with the more common SCX-MS can provide a promising and comprehensive strategy for accelerating the development of complex protein therapeutics.

[1]  S. Kiessig,et al.  Characterization of therapeutic mAb charge heterogeneity by iCIEF coupled to mass spectrometry (iCIEF–MS) , 2022, Electrophoresis.

[2]  Tian Xu,et al.  Automated Capillary Isoelectric Focusing-Mass Spectrometry with Ultrahigh Resolution for Characterizing Microheterogeneity and Isoelectric Points of Intact Protein Complexes. , 2022, Analytical chemistry.

[3]  A. Guttman,et al.  Evaluation of an icIEF‐MS system for comparable charge variant analysis of biotherapeutics with rapid peak identification by mass spectrometry , 2022, Electrophoresis.

[4]  A. Rathore,et al.  Analytical Similarity Assessment of Biosimilars: Global Regulatory Landscape, Recent Studies and Major Advancements in Orthogonal Platforms , 2022, Frontiers in Bioengineering and Biotechnology.

[5]  J. Pawliszyn,et al.  Whole-Column Imaging Detection for Capillary Isoelectric Focusing: Its Applications in Pharmaceutical Industry and Recent Development of the Technology , 2022, TrAC Trends in Analytical Chemistry.

[6]  S. Štěpánová,et al.  Applications of capillary electromigration methods for separation and analysis of proteins (2017-mid 2021) - A review. , 2022, Analytica chimica acta.

[7]  M. Szigeti,et al.  Capillary electrophoresis and the biopharmaceutical industry: Therapeutic protein analysis and characterization , 2021 .

[8]  D. Guillarme,et al.  Ultra-short ion-exchange columns for fast charge variants analysis of therapeutic proteins. , 2021, Journal of chromatography. A.

[9]  D. Guillarme,et al.  Towards a simple on-line coupling of ion exchange chromatography and native mass spectrometry for the detailed characterization of monoclonal antibodies. , 2021, Journal of chromatography. A.

[10]  A. Heck,et al.  High-Resolution Native Mass Spectrometry , 2021, Chemical reviews.

[11]  C. Huber,et al.  Simultaneous Monitoring of Monoclonal Antibody Variants by Strong Cation-Exchange Chromatography Hyphenated to Mass Spectrometry to Assess Quality Attributes of Rituximab-Based Biotherapeutics , 2021, International journal of molecular sciences.

[12]  R. Rustandi,et al.  Recent advances in isoelectric focusing of proteins and peptides. , 2021, Journal of chromatography. A.

[13]  Alexander B. Schwahn,et al.  New Insights into the Chromatography Mechanisms of Ion-Exchange Charge Variant Analysis: Dispelling Myths and Providing Guidance for Robust Method Optimization. , 2020, Analytical chemistry.

[14]  Ning Li,et al.  A Versatile, Sensitive, and Robust Native LC-MS Platform for Intact Mass Analysis of Protein Drugs. , 2020, Journal of the American Society for Mass Spectrometry.

[15]  J. Bones,et al.  Comparing different domains of analysis for the characterisation of N-glycans on monoclonal antibodies , 2019, Journal of pharmaceutical analysis.

[16]  E. Gentalen,et al.  A novel microchip‐based imaged CIEF‐MS system for comprehensive characterization and identification of biopharmaceutical charge variants , 2019, Electrophoresis.

[17]  Ying Ge,et al.  Comprehensive characterization of monoclonal antibody by Fourier transform ion cyclotron resonance mass spectrometry , 2018, mAbs.

[18]  Guanbo Wang,et al.  High Resolution Capillary Isoelectric Focusing Mass Spectrometry Analysis of Peptides, Proteins, And Monoclonal Antibodies with a Flow-through Microvial Interface. , 2018, Analytical chemistry.

[19]  C. Montealegre,et al.  Coupling imaged capillary isoelectric focusing with mass spectrometry using a nanoliter valve , 2018, Electrophoresis.

[20]  Qiangwei Xia,et al.  Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants. , 2018, Analytical chemistry.

[21]  Wolfgang Friess,et al.  N-glycosylation heterogeneity and the influence on structure, function and pharmacokinetics of monoclonal antibodies and Fc fusion proteins. , 2016, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[22]  Davy Guillarme,et al.  Ion-exchange chromatography for the characterization of biopharmaceuticals. , 2015, Journal of pharmaceutical and biomedical analysis.

[23]  W. Xu,et al.  Chromatographic analysis of the acidic and basic species of recombinant monoclonal antibodies , 2012, mAbs.

[24]  R. Ionescu,et al.  Heterogeneity of monoclonal antibodies revealed by charge-sensitive methods. , 2008, Current pharmaceutical biotechnology.

[25]  J. Ramsey,et al.  Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry. , 2008, Analytical chemistry.

[26]  F. Sobott,et al.  Advances in native high-performance liquid chromatography and intact mass spectrometry for the characterization of biopharmaceutical products. , 2018, Journal of separation science.

[27]  Wei Wang,et al.  Antibody structure, instability, and formulation. , 2007, Journal of pharmaceutical sciences.