Real-time impedance analysis of silica nanowire toxicity on epithelial breast cancer cells.

Silica nanowires have great potential for usage in the development of highly sensitive in vivo biosensors used for biomarker monitoring. However, careful analysis of nanowire toxicity is required prior to placing these sensors within the human body. This paper describes a real-time and quantitative analysis of nanowire cytotoxicity using impedance spectroscopy; improving upon studies that have utilized traditional endpoint assays. Silica nanowires were grown using the vapor liquid solid (VLS) method, mixed with Dulbecco's Modified Eagle Medium (DMEM) and exposed to Hs578T epithelial breast cancer cells at concentrations of 0 μg ml(-1), 1 μg ml(-1), 50 μg ml(-1) and 100 μg ml(-1). Real-time cellular responses to silica nanowires confirm that while not cytotoxic, silica nanowires at high concentrations (≥50 μg ml(-1)) are toxic to cells, and also suggest that cell death is due to mechanical disturbances of high numbers of nanowires.

[1]  Arun Majumdar,et al.  Label-free protein recognition two-dimensional array using nanomechanical sensors. , 2008, Nano letters.

[2]  A. Goy,et al.  Ovarian cancer biomarkers for molecular biosensors and translational medicine , 2010, Expert review of molecular diagnostics.

[3]  H. Pham,et al.  Electrochemical impedance spectroscopy; a tool for organic coatings optimizations , 1996 .

[4]  S. Bhansali,et al.  Optimized growth and integration of silica nanowires into interdigitated microelectrode structures for biosensing , 2012 .

[5]  Gengfeng Zheng,et al.  Multiplexed electrical detection of cancer markers with nanowire sensor arrays , 2005, Nature Biotechnology.

[6]  I. Giaever,et al.  Micromotion of mammalian cells measured electrically. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[7]  Wen-Tso Liu,et al.  Nanoparticles and their biological and environmental applications. , 2006, Journal of bioscience and bioengineering.

[8]  C. Yi,et al.  Effects of Silicon Nanowires on HepG2 Cell Adhesion and Spreading , 2007, Chembiochem : a European journal of chemical biology.

[9]  S. Nie,et al.  Nanotechnology applications in cancer. , 2007, Annual review of biomedical engineering.

[10]  Michael Fischer,et al.  Microcavity array (MCA)-based biosensor chip for functional drug screening of 3D tissue models. , 2008, Biosensors & bioelectronics.

[11]  Jun Sun,et al.  Cytotoxicity and cellular uptake of iron nanowires. , 2010, Biomaterials.

[12]  Herman P. Schwan,et al.  Electric Characteristics of Tissues , 1963 .

[13]  S. J. Kang,et al.  Expression and Distribution of Extracellular Matrices during Corneal Wound Healing after Keratomileusis in Rabbits , 1998, Ophthalmologica.

[14]  H. Schwan Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.

[15]  I. Tothill Biosensors for cancer markers diagnosis. , 2009, Seminars in cell & developmental biology.

[16]  F. Fabregat‐Santiago,et al.  Determination of carrier density of ZnO nanowires by electrochemical techniques , 2006 .

[17]  A. Lu,et al.  Magnetic nanoparticles: synthesis, protection, functionalization, and application. , 2007, Angewandte Chemie.

[18]  T. Zhukov,et al.  Voltammetric detection of cancer biomarkers exemplified by interleukin-10 and osteopontin with silica nanowires , 2007 .

[19]  In vitro proliferating cell models to study cytotoxicity of silica nanowires. , 2010, Nanomedicine : nanotechnology, biology, and medicine.

[20]  R. Nitschke,et al.  Quantum dots versus organic dyes as fluorescent labels , 2008, Nature Methods.

[21]  S. Bhansali,et al.  Metal-Decorated Silica Nanowires: An Active Surface-Enhanced Raman Substrate for Cancer Biomarker Detection , 2008 .