Estudo da influência do diâmetro do orifício piloto na resistência ao arrancamento do parafuso pedicular

The influence of the diameter of the pilot hole compared to the inner diameter of the screw on the pull-out resistance of a pedicular screw was studied. 5-, 6-, and 7-mm USS system screws for vertebral fixation were inserted into wood, polyurethane and bone test bodies. The pilot hole for screw insertion was drilled with burrs of smaller, equal or wider diameter than the inner diameter of the screw. Mechanical pull-out assays were performed using a universal testing machine. In the wood, polyurethane and bone test bodies, a pilot hole drilled with burrs of a wider diameter than the inner diameter of the screw produced reduced maximum pull-out strength on the implants, with statistical significance. The drilling diameter of the pilot hole compared to the inner diameter of the screw influences implant pull-out strength, with an increased pull-out resistance being observed with the use of smaller diameter burrs as compared to the inner diameter, and a reduction of pull-out resistance being observed with the use of burrs of a wider diameter than the inner diameter of the screw.

[1]  R. Molinari,et al.  Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine. , 2005, Journal of neurosurgery. Spine.

[2]  C. Chao,et al.  Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  J. K. Webb,et al.  Pedicle screw fixation in spinal disorders: A European view , 2005, European Spine Journal.

[4]  B. Browner,et al.  Skeletal trauma: basic science, Management and reconstruction , 2003 .

[5]  F. Abrahão Estudo da influência da técnica de preparação dos pedículos vertebrais na resistência ao arrancamento dos implantes , 2002 .

[6]  A. Valdevit,et al.  Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. , 2001, The spine journal : official journal of the North American Spine Society.

[7]  E. Benzel,et al.  Effects of hole preparation on screw pullout resistance and insertional torque: a biomechanical study. , 2001, Journal of neurosurgery.

[8]  K. Okuyama,et al.  Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. , 2000, Spine.

[9]  W. Hutton,et al.  Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength? , 1998, Journal of spinal disorders.

[10]  T C Hearn,et al.  Insertional Torque and Pull‐out Strengths of Conical and Cylindrical Pedicle Screws in Cadaveric Bone , 1996, Spine.

[11]  V K Goel,et al.  Effect of Specimen Fixation Method on Pullout Tests of Pedicle Screws , 1996, Spine.

[12]  J. Cordey,et al.  Bone deformation by thread-cutting and thread-forming cortex screws , 1995 .

[13]  S. Cook,et al.  Effects of Bone Mineral Density on Pedicle Screw Fixation , 1994, Spine.

[14]  E. Benzel Biomechanics of Spine Stabilization , 1994 .

[15]  W C Hutton,et al.  Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws. , 1994, Journal of spinal disorders.

[16]  M H Krag,et al.  Hole Preparation Techniques for Transpedicle Screws Effect on Pull‐Out Strength from Human Cadaveric Vertebrae , 1991, Spine.

[17]  D J Downey,et al.  Optimizing Bone Screw Pullout Force , 1990, Journal of orthopaedic trauma.