An immobilization system for claustrophobic patients in head-and-neck intensity-modulated radiation therapy.
暂无分享,去创建一个
[1] Jatinder R Palta,et al. Evaluation of intrafraction patient movement for CNS and head & neck IMRT. , 2004, Medical physics.
[2] J. Tsai,et al. Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. , 1998, International journal of radiation oncology, biology, physics.
[3] Steve Webb,et al. Intensity-Modulated Radiation Therapy , 1996, International journal of radiation oncology, biology, physics.
[4] Shinichi Shimizu,et al. Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. , 2002, International journal of radiation oncology, biology, physics.
[5] A L Boyer,et al. Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[6] S L Meeks,et al. Preliminary experience with frameless stereotactic radiotherapy. , 1998, International journal of radiation oncology, biology, physics.
[7] G T Chen,et al. Initial clinical experience with a video-based patient positioning system. , 1999, International journal of radiation oncology, biology, physics.
[8] Shinichi Shimizu,et al. Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system. , 2003, International journal of radiation oncology, biology, physics.
[9] D Yan,et al. The use of on-line image verification to estimate the variation in radiation therapy dose delivery. , 1993, International journal of radiation oncology, biology, physics.
[10] A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[11] P. M. Len,et al. 111 Clinical experience of breathing synchronized radiotherapy procedure at the University of California Davis Cancer Center , 1999 .
[12] R Bale,et al. Repositioning accuracy: comparison of a noninvasive head holder with thermoplastic mask for fractionated radiotherapy and a case report. , 1998, International journal of radiation oncology, biology, physics.
[13] M. V. van Herk,et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.
[14] R Mohan,et al. The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. , 2001, International journal of radiation oncology, biology, physics.
[15] H D Kubo,et al. Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy. , 1999, Medical physics.
[16] C. Enke,et al. Immobilization devices for intensity-modulated radiation therapy (IMRT). , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.
[17] Dirk Verellen,et al. Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[18] S L Meeks,et al. Image localization for frameless stereotactic radiotherapy. , 2000, International journal of radiation oncology, biology, physics.
[19] J Szanto,et al. A prospective comparison of three systems of patient immobilization for prostate radiotherapy. , 2000, International journal of radiation oncology, biology, physics.
[20] Mark P. Carol,et al. Peacock™: A system for planning and rotational delivery of intensity‐modulated fields , 1995, Int. J. Imaging Syst. Technol..
[21] J. Buatti,et al. The University of Florida frameless high-precision stereotactic radiotherapy system. , 1997, International journal of radiation oncology, biology, physics.
[22] J. Tsai,et al. A non-invasive immobilization system and related quality assurance for dynamic intensity modulated radiation therapy of intracranial and head and neck disease. , 1999, International journal of radiation oncology, biology, physics.
[23] D. Brizel,et al. Comparison of two head and neck immobilization systems. , 1997, International journal of radiation oncology, biology, physics.
[24] S L Meeks,et al. A high-precision system for conformal intracranial radiotherapy. , 2000, International journal of radiation oncology, biology, physics.