Detection of arterial emboli using Doppler ultrasound in rabbits.

The purpose of this study was to develop an animal model that could be used to test the ability of Doppler ultrasound to detect arterial emboli composed of materials that are often involved in cerebral emboli. Emboli introduced into the rabbit aorta via the left renal artery consisted of clotted whole blood, platelets, atheromatous material, fat, or air. The ultrasound examination was carried out continuously during the studies using a multifrequency transcranial Doppler apparatus with a 2-MHz probe, a sample volume of 15 mm, at a depth of 15 mm. The intensity of the Doppler spectrum was measured and displayed as a 15-shade color scale, each shade representing a 3-dB difference. The diameter of the aorta at the site of the ultrasound examination was similar to the diameter of the middle cerebral artery in humans. All 125 emboli introduced were clearly detected because they caused a Doppler signal at least 15 dB greater than that of the surrounding blood. These results show that the potential for emboli detection using Doppler ultrasound in the clinical situation is now considerable.

[1]  R. Young,et al.  Localization of the pyramidal tract in the internal capsule of man , 1977, Journal of the Neurological Sciences.

[2]  C. Fisher Thalamic pure sensory stroke , 1978, Neurology.

[3]  R. D'Agostino,et al.  Prevalence of silent stroke in patients presenting with initial stroke: the Framingham Study. , 1989, Stroke.

[4]  P. Smith,et al.  The cerebral complications of coronary artery bypass surgery. , 1988, Annals of the Royal College of Surgeons of England.

[5]  L R Sauvage,et al.  Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography. , 1990, Stroke.

[6]  M P Spencer,et al.  Experiments on decompression bubbles in the circulation using ultrasonic and electromagnetic flowmeters. , 1969, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[7]  R. Gosling,et al.  Monitoring middle cerebral artery blood velocity during carotid endarterectomy , 1986, The British journal of surgery.

[8]  L R Sauvage,et al.  The use of ultrasonics in the determination of arterial aeroembolism during open-heart surgery. , 1969, The Annals of thoracic surgery.

[9]  A. Rhoton,et al.  Microsurgical anatomy of the posterior cerebral artery. , 1978, Journal of neurosurgery.

[10]  U. Slager,et al.  PATHOLOGY OF THE CEREBRAL BLOOD VESSELS. , 1974 .

[11]  F. Umansky,et al.  Microanatomy of the anterior cerebral artery. , 1986, Surgical neurology.

[12]  P. Gates,et al.  Asymptomatic cerebral infarction in patients with chronic atrial fibrillation. , 1988, Stroke.

[13]  A. Rhoton,et al.  Microsurgical anatomy of the middle cerebral artery. , 1981, Journal of neurosurgery.

[14]  T. Treasure,et al.  CEREBRAL CONSEQUENCES OF CARDIOPULMONARY BYPASS , 1986, The Lancet.

[15]  J. Herndon,et al.  Use of ultrasound to detect fat emboli during total hip replacement. , 1975, Acta orthopaedica Scandinavica.

[16]  J. French,et al.  Neurologic and neuropsychological morbidity following major surgery: comparison of coronary artery bypass and peripheral vascular surgery. , 1987, Stroke.

[17]  C. Gyldensted,et al.  Silent cerebral infarction in chronic atrial fibrillation. , 1987, Stroke.

[18]  B Eiseman,et al.  Ultrasound detection of fat emboli. , 1972, Surgical forum.

[19]  E. Ritenour Doppler Ultrasound: Physics, Instrumentation and Clinical Applications , 1990 .