Comparison of active and passive damping methods for application in high power active power filter with LCL-filter

LCL-type filter possessing sufficient attenuation ratio for switching ripple with small LC parameters is appropriate to be used as output filter to get high slew rate of compensation current. However, LCL-filter, as a three order resonant circuit itself, is difficult to be stable. This paper compares active and passive methods for LCL filter resonance damping; assesses their suitability for the high power active power filter application and presents their benefits and drawbacks. The results presented show that both methods compensate harmonics effectively and attenuate switching ripple sufficiently. However, there are still some differences both in the filtering performance and the power losses in the high power application. The active methods require more sensors and increase algorithm complexity, while additional damping resistors are needed in the passive methods and result in large losses. Simulation validates the feasibility of the method proposed by this paper.

[1]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[2]  M.P. Kazmierkowski,et al.  Sensorless operation of active damping methods for three-phase PWM converters , 2005, Proceedings of the IEEE International Symposium on Industrial Electronics, 2005. ISIE 2005..

[3]  Guozhu Chen,et al.  A novel control approach for LCL-based shunt active power filter with high dynamic and steady-state performance , 2008, 2008 IEEE Power Electronics Specialists Conference.

[4]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .

[5]  P.A. Dahono A control method for DC-DC converter that has an LCL output filter based on new virtual capacitor and resistor concepts , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[6]  P.W. Lehn,et al.  Digital current control of a voltage source converter with active damping of LCL resonance , 2005, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..

[7]  Guozhu Chen,et al.  Study on shunt active power filter with high quality grid current waveform , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[8]  M. Salo,et al.  Comparison of Voltage-Source and Current-Source Shunt Active Power Filters , 2005, IEEE Transactions on Power Electronics.

[9]  S. Bernet,et al.  Simple sensorless active damping solution for three-phase PWM rectifier with LCL filter , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[10]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[11]  M. Liserre,et al.  Stability improvements of an LCL-filter based three-phase active rectifier , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[12]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[13]  Poh Chiang Loh,et al.  Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters , 2005, IEEE Transactions on Industry Applications.

[14]  A. Draou,et al.  A new state feedback based transient control of PWM AC to DC voltage type converters , 1995 .