Combined multi-body and finite element investigation of the effect of the seat height on acetabular implant stability during the activity of getting up

An important question in assessing the stability of a total hip arthroplasty is the effect of daily physical activities of patients. The aim of this study is to examine these effects when standing up from three different seat heights. A musculoskeletal body model has been modified to simulate the three different seat heights. The calculated muscle forces have been transferred to a finite element model of a pelvis. The pelvis model was created from a hemipelvis CT dataset. As an implant component, a metal socket with a polyethylene insert was used. A primary implantation situation was modelled. For the analysed patient activities the highest hip contact forces and the highest micromotions occur at the beginning of the motion. The results of this study show that standing up from a certain seat height can have a significant influence on the micromotions in the implant-bone interface.

[1]  R Huiskes,et al.  Total hip reconstruction in acetabular dysplasia. A finite element study. , 1993, The Journal of bone and joint surgery. British volume.

[2]  Michael Damsgaard,et al.  Analysis of musculoskeletal systems in the AnyBody Modeling System , 2006, Simul. Model. Pract. Theory.

[3]  W. Harris,et al.  Biologic fixation of total hip implants. Insights gained from a series of canine studies. , 2004, The Journal of bone and joint surgery. American volume.

[4]  R. Barauskas,et al.  Finite element analysis of stresses in the maxillary and mandibular dental arches and TMJ articular discs during clenching into maximum intercuspation, anterior and unilateral posterior occlusion. , 2007, Stomatologija.

[5]  R. Huiskes,et al.  Load transfer across the pelvic bone. , 1995, Journal of biomechanics.

[6]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[7]  Thomas D Taylor,et al.  Early wound healing around endosseous implants: a review of the literature. , 2005, The International journal of oral & maxillofacial implants.

[8]  L Cristofolini,et al.  In-vitro method for assessing femoral implant—bone micromotions in resurfacing hip implants under different loading conditions , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  E. Schneider,et al.  The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. , 2001, Journal of biomechanics.

[10]  M. Damsgaard,et al.  Muscle recruitment by the min/max criterion -- a comparative numerical study. , 2001, Journal of biomechanics.

[11]  G. Bergmann,et al.  Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. , 2000, Journal of biomechanics.

[12]  E. Grandjean Physiologische Arbeitsgestaltung : Leitfaden der Ergonomie , 1967 .

[13]  Bernhard N. Tillmann,et al.  Atlas der Anatomie des Menschen , 2010 .

[14]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[15]  M. Viceconti,et al.  A modified method for assigning material properties to FE models of bones. , 2008, Medical engineering & physics.

[16]  Jui-Ting Hsu,et al.  The relation between micromotion and screw fixation in acetabular cup , 2006, Comput. Methods Programs Biomed..

[17]  R M Pilliar,et al.  Radiographic and morphologic studies of load-bearing porous-surfaced structured implants. , 1981, Clinical orthopaedics and related research.

[18]  A. Phillips,et al.  Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions. , 2007, Medical engineering & physics.

[19]  A. Prassl,et al.  The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: Spatial orientation of the pelvis in different positions , 2005, Acta orthopaedica.

[20]  Lutz Claes,et al.  Internal loads in the human tibia during gait. , 2009, Clinical biomechanics.

[21]  Nina S Sverdlova,et al.  Principles of determination and verification of muscle forces in the human musculoskeletal system: Muscle forces to minimise bending stress. , 2010, Journal of biomechanics.

[22]  Kai-Nan An,et al.  Modeling of the muscle/tendon excursions and moment arms in the thumb using the commercial software anybody. , 2009, Journal of biomechanics.

[23]  A. Hill The heat of shortening and the dynamic constants of muscle , 1938 .

[24]  Rainer Bader,et al.  Finite element analysis of shear stresses at the implant-bone interface of an acetabular press-fit cup during impingement / Finite-Elemente-Berechnung der Schubspannungen im Implantat-Knochen-Interface einer acetabulären Press-Fit-Pfanne bei Impingement , 2007 .

[25]  K. An,et al.  The number of screws, bone quality, and friction coefficient affect acetabular cup stability. , 2007, Medical engineering & physics.

[26]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[27]  Marco Viceconti,et al.  Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy. , 2006, Journal of biomechanics.

[28]  E. Tanaka,et al.  Stress analysis in the mandibular condyle during prolonged clenching: A theoretical approach with the finite element method , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[29]  B. Kladny Rehabilitation bei jüngeren Endoprothesenpatienten , 2007, Der Orthopäde.

[30]  K A Mann,et al.  Elastic and viscoelastic properties of the human pubic symphysis joint: effects of lateral impact joint loading. , 2001, Journal of biomechanical engineering.

[31]  R. Barrack,et al.  Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. , 2001, The Orthopedic clinics of North America.

[32]  Marco Viceconti,et al.  An improved method for the automatic mapping of computed tomography numbers onto finite element models. , 2004, Medical engineering & physics.

[33]  A. Shirazi-Adl,et al.  Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. , 1993, Journal of biomedical materials research.

[34]  Hwj Rik Huiskes,et al.  Total hip reconstruction in acetabular dysplasia. , 1993 .

[35]  H Steinke,et al.  Plastinated body slices for verification of magnetic resonance tomography images. , 2001, Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft.

[36]  F. Zajac,et al.  A musculoskeletal model of the human lower extremity: the effect of muscle, tendon, and moment arm on the moment-angle relationship of musculotendon actuators at the hip, knee, and ankle. , 1990, Journal of biomechanics.

[37]  Liliane Juchli,et al.  Pflege : Praxis und Theorie der Gesundheits- und Krankenpflege , 1994 .