Influence of light intensity on dentin bond strength of self-etch systems.

The purpose of this study was to investigate the influence of light intensity on dentin bond strengths of four self-etch adhesive systems. The light intensities used to polymerize specimens were controlled at levels of 150, 300, 600, and 900 mW/cm2. The two-step self-etch adhesive systems Imperva Fluoro Bond and Mac Bond II, and the one-step self-etch systems Fluoro Bond Shake-One and One-Up Bond F Plus were used with their corresponding light-cured resins. Labial surfaces of lower bovine incisors were ground with #600 grit SiC paper to expose the dentin. The dentin surfaces were treated according to each manufacturer's instructions and bonded with resin composites. A shear bond strength test was performed and the data were analyzed by one-way ANOVA followed by Newman-Keuls multiple comparison at a level of 0.05. Statistical analysis of the data indicated that light intensity affected the dentin bond strengths of the adhesive systems tested. Significantly lower bond strengths were obtained by exposure to 150 mW/cm2, and there were no differences between the bond strengths obtained at 600 and 900 mW/cm2 for all the adhesive systems used. Further research will be required to clarify the irradiance-dependent properties of light-cured resin adhesive systems.

[1]  M. Taira,et al.  Analysis of Photo-initiators in Visible-light-cured Dental Composite Resins , 1988, Journal of dental research.

[2]  W. Cook Photopolymerization kinetics of dimethacrylates using the camphorquinone/amine initiator system , 1992 .

[3]  C. S. Fowler,et al.  Influence of selected variables on adhesion testing. , 1992, Dental materials : official publication of the Academy of Dental Materials.

[4]  W. Douglas,et al.  Curing light performance and polymerization of composite restorative materials. , 1992, Journal of dentistry.

[5]  A. Feilzer,et al.  Setting stresses in composites for two different curing modes. , 1993, Dental materials : official publication of the Academy of Dental Materials.

[6]  R. Nomoto,et al.  Effect of light intensity on polymerization of light-cured composite resins. , 1994, Dental materials journal.

[7]  J. W. Curtis,et al.  Effect of light intensity and exposure duration on cure of resin composite. , 1994, Operative dentistry.

[8]  M. Miyazaki,et al.  Influence of light intensity on shear bond strength to dentin. , 1995, American journal of dentistry.

[9]  M. Miyazaki,et al.  Effect of light exposure on fracture toughness and flexural strength of light-cured composites. , 1996, Dental materials : official publication of the Academy of Dental Materials.

[10]  A. Peutzfeldt,et al.  Surface hardness and wear of glass ionomers and compomers. , 1997, American journal of dentistry.

[11]  A. Peutzfeldt,et al.  Resin composites in dentistry: the monomer systems. , 1997, European journal of oral sciences.

[12]  M. Delaloye,et al.  Volume of the internal gap formed under composite restorations in vitro. , 1997, Journal of dentistry.

[13]  P. Koran,et al.  Effect of sequential versus continuous irradiation of a light-cured resin composite on shrinkage, viscosity, adhesion, and degree of polymerization. , 1998, American journal of dentistry.

[14]  M. Miyazaki,et al.  Evaluation of curing units used in private dental offices. , 1998, Operative dentistry.

[15]  C. Bowman,et al.  The Effects of Light Intensity, Temperature, and Comonomer Composition on the Polymerization Behavior of Dimethacrylate Dental Resins , 1999, Journal of dental research.

[16]  J. Stansbury Curing dental resins and composites by photopolymerization. , 2000, Journal of esthetic dentistry.

[17]  D C Watts,et al.  Light intensity effects on resin-composite degree of conversion and shrinkage strain. , 2000, Dental materials : official publication of the Academy of Dental Materials.

[18]  A. Rizkalla,et al.  Effect of stepped vs. continuous light curing exposure on bond strengths to dentin. , 2000, American journal of dentistry.

[19]  A. Peutzfeldt,et al.  Characterization of resin composites polymerized with plasma arc curing units. , 2000, Dental materials : official publication of the Academy of Dental Materials.

[20]  C. Bowman,et al.  The effect of cure rate on the mechanical properties of dental resins. , 2001, Dental materials : official publication of the Academy of Dental Materials.

[21]  N. Wilson,et al.  Practice maintenance: The use and maintenance of visible light activating units in general practice , 2001, British Dental Journal.

[22]  C. Davidson,et al.  Energy dependent polymerization of resin-based composite. , 2002, Dental materials : official publication of the Academy of Dental Materials.

[23]  Adhesion of single application bonding systems to bovine enamel and dentin. , 2002, Operative dentistry.

[24]  B. Hugo,et al.  The influence of plasma arc vs. halogen standard or soft-start irradiation on polymerization shrinkage kinetics of polymer matrix composites. , 2003, Journal of dentistry.

[25]  P. Jain,et al.  Depth of cure and microleakage with high-intensity and ramped resin-based composite curing lights. , 2003, Journal of the American Dental Association.

[26]  G. Danesh,et al.  Polymerisation characteristics of resin composites polymerised with different curing units. , 2004, Journal of dentistry.

[27]  N. Emami,et al.  Influence of light-curing procedures and photo-initiator/co-initiator composition on the degree of conversion of light-curing resins , 2005, Journal of materials science. Materials in medicine.

[28]  A. Peutzfeldt,et al.  Polymerization contraction of resin composite vs. energy and power density of light-cure. , 2005, European journal of oral sciences.

[29]  S. Uno,et al.  Reduced irradiation time in slow-curing of resin composite using an intensity-changeable light source. , 2005, Dental materials journal.