A Comprehensive Framework for the Characterization of the Complete Mitral Valve Geometry for the Development of a Population-Averaged Model

Simulations of the biomechanical behavior of the Mitral Valve (MV) based on simplified geometric models are difficult to interpret due to significant intra-patient variations and pathologies in the MV geometry. Thus, it is critical to use a systematic approach to characterization and population-averaging of the patient-specific models. We introduce a multi-scale modeling framework for characterizing the entire MV apparatus geometry via a relatively small set of parameters. The leaflets and annulus are analyzed using a superquadric surface model superimposed with fine-scale filtered level-set field. Filtering of fine-scale features is performed in a spectral space to allow control of resolution, resampling and robust averaging. Chordae tendineae structure is modeled using a medial axis representation with superimposed filtered pointwise cross-sectional area field. The chordae topology is characterized using orientation and spatial distribution functions. The methodology is illustrated with the analysis of an ovine MV microtomography imaging data.

[1]  Ajit P. Yoganathan,et al.  A High-Fidelity and Micro-anatomically Accurate 3D Finite Element Model for Simulations of Functional Mitral Valve , 2013, FIMH.

[2]  Dorin Comaniciu,et al.  An integrated framework for finite-element modeling of mitral valve biomechanics from medical images: Application to MitralClip intervention planning , 2012, Medical Image Anal..

[3]  J. Douglas Faires,et al.  Numerical Analysis , 1981 .

[4]  W. S. Ring,et al.  Finite element analysis of the mitral valve. , 1993, The Journal of heart valve disease.

[5]  K. Gröchenig RECONSTRUCTION ALGORITHMS IN IRREGULAR SAMPLING , 1992 .

[6]  W. M. Swanson,et al.  Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure , 1974, Circulation research.

[7]  Qing Huo Liu,et al.  A HIGH ACCURACY CONFORMAL METHOD FOR EVALUATING THE DISCONTINUOUS FOURIER TRANSFORM , 2010 .

[8]  Rangasami L. Kashyap,et al.  Building Skeleton Models via 3-D Medial Surface/Axis Thinning Algorithms , 1994, CVGIP Graph. Model. Image Process..

[9]  Boyce E. Griffith,et al.  Emerging Trends in Heart Valve Engineering: Part I. Solutions for Future , 2014, Annals of Biomedical Engineering.

[10]  Wei Sun,et al.  Computational modeling of cardiac valve function and intervention. , 2014, Annual review of biomedical engineering.

[11]  Alberto Redaelli,et al.  Mitral valve finite-element modelling from ultrasound data: a pilot study for a new approach to understand mitral function and clinical scenarios , 2008, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[12]  Statistical assessment of normal mitral annular geometry using automated three-dimensional echocardiographic analysis. , 2014, The Annals of thoracic surgery.

[13]  Franc Solina,et al.  Segmentation and Recovery of Superquadrics , 2000, Computational Imaging and Vision.

[14]  N. Wilson,et al.  Mitral Valve Geometry in Paediatric Rheumatic Mitral Regurgitation , 2015, Pediatric Cardiology.

[15]  Jorge J. Moré,et al.  The Levenberg-Marquardt algo-rithm: Implementation and theory , 1977 .

[16]  T. Guy,et al.  Mitral valve prolapse. , 2012, Annual review of medicine.

[17]  Leslie Greengard,et al.  Accelerating the Nonuniform Fast Fourier Transform , 2004, SIAM Rev..

[18]  Rui Ma,et al.  Topology-varying 3D shape creation via structural blending , 2014, ACM Trans. Graph..

[19]  Robert C Gorman,et al.  A methodology for assessing human mitral leaflet curvature using real-time 3-dimensional echocardiography. , 2008, The Journal of thoracic and cardiovascular surgery.

[20]  D. Berdajs,et al.  A new classification of the mitral papillary muscle. , 2005, Medical science monitor : international medical journal of experimental and clinical research.

[21]  Andrew W. Siefert,et al.  In vitro mitral valve simulator mimics systolic valvular function of chronic ischemic mitral regurgitation ovine model. , 2013, The Annals of thoracic surgery.

[22]  Q. Wang,et al.  Finite Element Modeling of Mitral Valve Dynamic Deformation Using Patient-Specific Multi-Slices Computed Tomography Scans , 2012, Annals of Biomedical Engineering.

[23]  Gil Marom,et al.  A general three-dimensional parametric geometry of the native aortic valve and root for biomechanical modeling. , 2012, Journal of biomechanics.

[24]  Fotis Sotiropoulos,et al.  Toward patient-specific simulations of cardiac valves: state-of-the-art and future directions. , 2013, Journal of biomechanics.

[25]  Umberto Morbiducci,et al.  The Evolution of Computational Hemodynamics as a Clinical Tool in Decision Making, Patient Specific Treatment and Clinical Management , 2014, Annals of Biomedical Engineering.

[26]  Ahnryul Choi,et al.  A novel finite element-based patient-specific mitral valve repair: virtual ring annuloplasty. , 2014, Bio-medical materials and engineering.

[27]  Neelakantan Saikrishnan,et al.  A Novel Left Heart Simulator for the Multi-modality Characterization of Native Mitral Valve Geometry and Fluid Mechanics , 2013, Annals of Biomedical Engineering.

[28]  L. Paquette,et al.  Congenital Heart Disease in Low-Birth-Weight Infants: Effects of Small for Gestational Age (SGA) Status and Maturity on Postoperative Outcomes , 2014, Pediatric Cardiology.