In vivo kinematic determination of total knee arthroplasty from squatting to standing.
暂无分享,去创建一个
Mohamed R Mahfouz | Richard D Komistek | R. Komistek | M. Mahfouz | Fei Liu | Ray C Wasielewski | R. Wasielewski | Fei Liu | Toshihiro Ohdera | Hirohide Miyamoto | T. Ohdera | Hirohide Miyamoto
[1] D A Dennis,et al. In Vivo Knee Kinematics Derived Using an Inverse Perspective Technique , 1996, Clinical orthopaedics and related research.
[2] Bruce D Beynnon,et al. Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. , 2003, The Journal of arthroplasty.
[3] T. Johnson,et al. Anterior tibial post impingement in a posterior stabilized total knee arthroplasty , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[4] P. Fowler,et al. Anatomy of the posterior cruciate ligament , 1989, The American journal of sports medicine.
[5] Richard D. Komistek,et al. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images , 2003, IEEE Transactions on Medical Imaging.
[6] R. Warren,et al. An in vitro biomechanical evaluation of anterior-posterior motion of the knee. Tibial displacement, rotation, and torque. , 1982, The Journal of bone and joint surgery. American volume.
[7] S. Yoshino,et al. Recovery of full flexion after total knee replacement in rheumatoid arthritis – a follow-up study , 1997, International Orthopaedics.
[8] Richard D Komistek,et al. An Intraoperative Pressure-Measuring Device Used in Total Knee Arthroplasties and Its Kinematics Correlations , 2004, Clinical orthopaedics and related research.
[9] G. Li,et al. Cruciate-retaining and cruciate-substituting total knee arthroplasty: an in vitro comparison of the kinematics under muscle loads. , 2001, The Journal of arthroplasty.
[10] P S Walker,et al. Geometry and motion of the knee for implant and orthotic design. , 1985, Journal of biomechanics.
[11] Johan Kärrholm,et al. Kinematics of successful knee prostheses during weight-bearing: Three-dimensional movements and positions of screw axes in the Tricon-M and Miller-Galante designs , 2005, Knee Surgery, Sports Traumatology, Arthroscopy.
[12] V. Pinskerova,et al. Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI , 2000 .
[13] Richard D Komistek,et al. In vivo comparison of femorotibial contact positions for press-fit posterior stabilized and posterior cruciate-retaining total knee arthroplasties. , 2002, The Journal of arthroplasty.
[14] T P Andriacchi,et al. Interaction between intrinsic knee mechanics and the knee extensor mechanism , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[15] W. Hein,et al. Bietet das NexGen LPS Flex mobile-Knieprothesensystem Vorteile gegenüber dem NexGen LPS? , 2005 .
[16] D A Dennis,et al. In Vivo Anteroposterior Femorotibial Translation of Total Knee Arthroplasty: A Multicenter Analysis , 1998, Clinical orthopaedics and related research.
[17] J B Stiehl,et al. Femoral condylar lift-off in vivo in total knee arthroplasty. , 2001, The Journal of bone and joint surgery. British volume.
[18] D. Dennis,et al. In Vivo Fluoroscopic Analysis of the Normal Human Knee , 2003, Clinical orthopaedics and related research.
[19] R. Komistek,et al. In vivo determination of knee kinematics for Japanese subjects having either a low contact stress rotating platform or an anteroposterior glide total knee arthroplasty. , 2005, The Journal of arthroplasty.
[20] Mohamed R Mahfouz,et al. A Multicenter Analysis of Axial Femorotibial Rotation after Total Knee Arthroplasty , 2004, Clinical orthopaedics and related research.
[21] Mohamed R Mahfouz,et al. Multicenter Determination of In Vivo Kinematics After Total Knee Arthroplasty , 2003, Clinical orthopaedics and related research.