An efficient cardiac signal enhancement using time–frequency realization of leaky adaptive noise cancelers for remote health monitoring systems

Abstract Nowadays telecardiology is an important tool in cardiac diagnosis from a remote location. During Electrocardiogram (ECG) or Cardiac Signal acquisition several artifacts strongly affect the ST segment, degrade the signal quality, frequency resolution, produce large amplitude signals in ECG that can resemble PQRST waveforms and mask the tiny features that are important for clinical monitoring and diagnosis. So the extraction of high-resolution cardiac signals from recordings contaminated with artifacts is an important issue to investigate. In this paper, various novel block based time–frequency domain adaptive filter structures for cardiac signal enhancement are presented. These filters estimate the deterministic components of the cardiac signal and remove the noise component. The Block Leaky Least Mean Square (BLLMS) algorithm, being the solution of the steepest descent strategy for minimizing the mean squared error in a complete signal occurrence, is shown to be steady-state unbiased and with a lower variance than the LMS algorithm. To improve the filtering capability some variants of BLLMS, Block Normalized LLMS (BNLLMS) and Block Error Normalized LLMS (BENLLMS) algorithms are implemented in both time domain (TD) and frequency domains (FD). Finally, we have applied these algorithms on real cardiac signals obtained from the MIT-BIH data base and compared their performance with the conventional LLMS algorithm. The results show that the performance of the block based algorithms is superior to the LLMS counterparts in terms of signal to noise ratio improvement (SNRI), excess mean square error (EMSE) and misadjustment (M). Among all the algorithms FDBENLLMS achieves higher SNRI than other techniques. These values are 25.8713 dB, 20.1548 dB, 21.6718 dB and 20.7131 dBs for power line interference (PLI), baseline wander (BW), muscle artifacts (MA) and electrode motion artifacts (EM) removal.

[1]  Álvaro Alesanco Iglesias,et al.  Clinical Assessment of Wireless ECG Transmission in Real-Time Cardiac Telemonitoring , 2010, IEEE Transactions on Information Technology in Biomedicine.

[2]  Marian Kotas,et al.  Application of projection pursuit based robust principal component analysis to ECG enhancement , 2006, Biomed. Signal Process. Control..

[3]  Pablo Laguna,et al.  Steady-state MSE convergence of LMS adaptive filters with deterministic reference inputs with applications to biomedical signals , 2000, IEEE Trans. Signal Process..

[4]  Pablo Laguna,et al.  Block adaptive filters with deterministic reference inputs for event-related signals: BLMS and BRLS , 2002, IEEE Trans. Signal Process..

[5]  Subhasis Chaudhuri,et al.  Body Movement Activity Recognition for Ambulatory Cardiac Monitoring , 2007, IEEE Transactions on Biomedical Engineering.

[6]  P.S. Hamilton,et al.  A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG , 1996, IEEE Transactions on Biomedical Engineering.

[7]  Ali H. Sayed,et al.  Adaptive Filters , 2008 .

[8]  Rui Seara,et al.  Leaky-FXLMS algorithm: stochastic analysis for Gaussian data and secondary path modeling error , 2005, IEEE Transactions on Speech and Audio Processing.

[9]  Ivan Dotsinsky,et al.  Power-line interference elimination from ECG in case of non-multiplicity between the sampling rate and the power-line frequency , 2008, Biomed. Signal Process. Control..

[10]  B. Farhang-Boroujeny,et al.  Adaptive Filters: Theory and Applications , 1999 .

[11]  Fei Hu,et al.  Privacy-Preserving Telecardiology Sensor Networks: Toward a Low-Cost Portable Wireless Hardware/Software Codesign , 2007, IEEE Transactions on Information Technology in Biomedicine.

[12]  S. Haykin,et al.  Adaptive Filter Theory , 1986 .

[13]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[14]  N.V. Thakor,et al.  Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection , 1991, IEEE Transactions on Biomedical Engineering.

[15]  Rui Seara,et al.  Leaky delayed LMS algorithm: stochastic analysis for Gaussian data and delay modeling error , 2004, IEEE Transactions on Signal Processing.

[16]  Fahim Sufi,et al.  Novel methods of faster cardiovascular diagnosis in wireless telecardiology , 2009, IEEE Journal on Selected Areas in Communications.

[17]  S. Poornachandra,et al.  Subband-Adaptive Shrinkage for Denoising of ECG Signals , 2006, EURASIP J. Adv. Signal Process..

[18]  S. Douglas A family of normalized LMS algorithms , 1994, IEEE Signal Processing Letters.

[19]  Behrouz Farhang-Boroujeny,et al.  Analysis of the frequency-domain block LMS algorithm , 2000, IEEE Trans. Signal Process..

[20]  Jun Cheng,et al.  A Wearable Smartphone-Based Platform for Real-Time Cardiovascular Disease Detection Via Electrocardiogram Processing , 2010, IEEE Transactions on Information Technology in Biomedicine.

[21]  Rafi Ahamed Shaik,et al.  Efficient sign based normalized adaptive filtering techniques for cancelation of artifacts in ECG signals: Application to wireless biotelemetry , 2011, Signal Process..

[22]  Tyseer Aboulnasr,et al.  Leaky LMS algorithm: MSE analysis for Gaussian data , 1997, IEEE Trans. Signal Process..

[23]  M. Z. U. Rahman,et al.  Efficient and Simplified Adaptive Noise Cancelers for ECG Sensor Based Remote Health Monitoring , 2012, IEEE Sensors Journal.

[24]  William P. Marnane,et al.  Energy-Efficient Low Duty Cycle MAC Protocol for Wireless Body Area Networks , 2009, IEEE Transactions on Information Technology in Biomedicine.

[25]  Alexander Schlaefer,et al.  A Fast Lane Approach to LMS prediction of respiratory motion signals , 2008, Biomed. Signal Process. Control..