A rapid reusable fiber optic biosensor for detecting cocaine metabolites in urine.

Analyte 2000, a four-channel fiber optic biosensor (FOB), was used for analysis of cocaine and its metabolites (COC) in human urine using a competitive fluorescence immunoassay. Binding of antibenzoylecgonine monoclonal antibody (mAb) to the casein-benzoylecgonine Ag-coated, tapered optical fibers was inhibited by COC. Bound mAb, which inversely correlated with COC concentration, was quantitated by fluorescence produced by evanescent excitation of bound cyanine dye-tagged antimouse antibody (CY5-Ab). The effective concentration range of benzoylecgonine (BE) for inhibiting the fluorescent signals was 0.75-50 ng/mL, with IC50 of 9.0 ng/mL. This FOB had similar affinities for BE, cocaine, and cocaethylene, but very low affinities for ecgonine and ecgonine methyl ester. A sensitivity of 100% and a specificity of 96% were achieved when 54 human urine specimens were analyzed by FOB (cutoff, 300 ng/mL COC) and GC-MS (cutoff, 150 ng/mL BE). All results were in agreement except for one positive FOB result with a GC-MS BE concentration of 148 ng/mL. In addition, regeneration and reuse of the fiber for multiple analyses were performed successfully with no carryover from specimens containing high COC concentrations to specimens containing low COC concentrations.

[1]  R. Schwartz,et al.  Assessment of an automated solid phase competitive fluoroimmunoassay for benzoylecgonine in untreated urine. , 1999, Journal of immunological methods.

[2]  M. Huestis,et al.  Differentiating new marijuana use from residual drug excretion in occasional marijuana users. , 1998, Journal of analytical toxicology.

[3]  J M Calvert,et al.  Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces. , 1989, Analytical biochemistry.

[4]  N. Nath,et al.  Evanescent wave fiber optic fluorosensor: effect of tapering configuration on the signal acquisition , 1998 .

[5]  U. Narang,et al.  Fiber optic-based biosensor for ricin. , 1997, Biosensors & bioelectronics.

[6]  E. Cone,et al.  Simultaneous assay of cocaine, heroin and metabolites in hair, plasma, saliva and urine by gas chromatography-mass spectrometry. , 1994, Journal of chromatography. B, Biomedical applications.

[7]  A T Eldefrawi,et al.  Evaluation of a fiber optic immunosensor for quantitating cocaine in coca leaf extracts. , 1997, Biosensors & bioelectronics.

[8]  Tomas Hirschfeld,et al.  Effect of numerical aperture on signal level in cylindrical waveguide evanescent fluorosensors. , 1987, Applied optics.

[9]  E. Cone,et al.  Simultaneous measurement of cocaine, cocaethylene, their metabolites, and "crack" pyrolysis products by gas chromatography-mass spectrometry. , 1994, Clinical chemistry.

[10]  S. Salamone,et al.  ONTRAK TESTCUP: a novel, on-site, multi-analyte screen for the detection of abused drugs. , 1995, Journal of analytical toxicology.

[11]  Frances S. Ligler,et al.  A fiber optic biosensor: combination tapered fibers designed for improved signal acquisition , 1993 .

[12]  Jeremy Wright,et al.  Fiber optic biosensor for cyclodiene insecticides , 1997 .

[13]  Frances S. Ligler,et al.  Portable multichannel fiber optic biosensor for field detection , 1997 .

[14]  N. Anis,et al.  A fiber-optic cocaine biosensor. , 1995, Analytical biochemistry.

[15]  Nabil A. Anis,et al.  Reusable fiber optic immunosensor for rapid detection of imazethapyr herbicide , 1993 .

[16]  R. H. Kline,et al.  Fiber optic immunosensor for polychlorinated biphenyls , 1995 .

[17]  Gilbert Boisde,et al.  Chemical and Biochemical Sensing with Optical Fibers and Waveguides , 1996 .

[18]  Kim R. Rogers,et al.  Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases. , 1991 .

[19]  F. Ligler,et al.  Detection of endotoxin using an evanescent wave fiber-optic biosensor , 1996, Applied biochemistry and biotechnology.

[20]  K R Rogers,et al.  Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases. , 1991, Fundamental and applied toxicology : official journal of the Society of Toxicology.

[21]  K R Rogers,et al.  Acetylcholine receptor fiber-optic evanescent fluorosensor. , 1989, Analytical biochemistry.

[22]  R. Braithwaite,et al.  A preliminary evaluation of five rapid detection kits for on site drugs of abuse screening. , 1995, Addiction.

[23]  H M Widmer,et al.  Fiber-optic evanescent wave biosensor for the detection of oligonucleotides. , 1996, Analytical chemistry.

[24]  J. Andrade,et al.  Remote fiber-optic biosensors based on evanescent-excited fluoro-immunoassay: Concept and progress , 1985, IEEE Transactions on Electron Devices.

[25]  D Wong,et al.  Chemical and Biochemical Sensing with Optical Fibers and Waveguides , 1997 .

[26]  D. Jarvie,et al.  Evaluation of Bionike One-Step Tests for the Detection of Drugs of Abuse in Urine , 1997, Annals of clinical biochemistry.