Multi-source effect in magnetizing-based eddy current testing sensor for surface crack in ferromagnetic materials

Abstract The mechanism of widely applied magnetizing-based eddy current testing (MB-ECT) sensor for ferromagnetic materials is simply emphasized by “the magnetization eliminates the non-uniformity of the permeability and increases the penetration depth”, resulting in rough application for non-destructive testing (NDT). Hence, the neglected permeability distortion around the surface crack is pointed out and analyzed at different magnetization states. In this paper, the multi-source effect of MB-ECT method is analyzed using the equivalent source method. The disturbed magnetic field source is actually composed of the primary magnetic leakage field, secondary disturbed magnetic field caused by the crack itself and the permeability distortion around the crack. Furthermore, the influence of the magnetizing current and the probe lift-off are investigated by finite element analysis (FEA). The simulation result shows “concave” feature as a consequence of the permeability distortion. A series of experiments are designed to analyze the dominant signal components under different conditions. The magnetizing current selection in MB-ECT method corresponds to a unique shape while plotting the signal amplitude as a function of the magnetizing current and lift-off of the probe. This study reveals the multi-source effect in the mechanism of MB-ECT sensors and provides the basic theory or analysis principles for the precision crack evaluation.

[1]  D. Jiles Introduction to Magnetism and Magnetic Materials , 2015 .

[2]  X. Jian,et al.  Enhancement of EMAT and eddy current using a ferrite back-plate , 2007 .

[3]  David L. Atherton,et al.  Use of magnetically-saturated regions in remote field eddy current tools , 1989 .

[4]  Y. Le Bihan,et al.  Multi sensor probe and defect classification in eddy current tubing inspection , 2006 .

[5]  Yong Wang,et al.  A novel TMR-based MFL sensor for steel wire rope inspection using the orthogonal test method , 2015 .

[6]  Noboru Niguchi,et al.  Flux-focusing eddy current sensor with magnetic saturation for detection of water pipe defects , 2016 .

[7]  C. V. Dodd,et al.  Eddy current inspection of ferromagnetic materials using pulsed magnetic saturation , 1988 .

[8]  S B Palmer,et al.  The magnetic leakage field of surface-breaking cracks , 1986 .

[9]  R. Vaillancourt,et al.  Analytical solutions to eddy-current testing problems for a layered medium with varying properties , 1997 .

[10]  Dehui Wu,et al.  3-D FEM Simulation and Analysis on the Best Range of Lift-off Values in MFL Testing , 2015 .

[11]  Toyokazu Tada,et al.  Development of magnetic eddy current testing techniques , 2017 .

[12]  Long Li,et al.  A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead , 2017, Sensors.

[13]  R. Rabinovici Nonlinear eddy current effects in ferromagnetic materials in the presence of DC magnetic fields , 1991 .

[14]  C. Graham,et al.  Introduction to Magnetic Materials , 1972 .

[15]  Renyang He,et al.  A Method for Improving SNR of Drill Pipe Leakage Flux Testing Signals by Means of Magnetic Concentrating Effect , 2015, IEEE Transactions on Magnetics.

[16]  Eric Berthelot,et al.  A model-based method for the characterisation of stress in magnetic materials using eddy current non-destructive evaluation , 2015 .

[17]  Gui Yun Tian,et al.  Reduction of lift-off effects for pulsed eddy current NDT , 2005 .

[18]  D. Davidov,et al.  High-frequency eddy-current technique for thickness measurement of micron-thick conducting layers , 2001 .

[19]  Theodoros Theodoulidis,et al.  Model of ferrite-cored probes for eddy current nondestructive evaluation , 2003 .

[20]  Yihua Kang,et al.  Magnetic compression effect in present MFL testing sensor , 2010 .

[21]  C. Dodd,et al.  ANALYTICAL SOLUTIONS TO EDDY--CURRENT PROBE COIL PROBLEMS. , 1968 .

[22]  Luis S. Rosado,et al.  A differential planar eddy currents probe: Fundamentals, modeling and experimental evaluation , 2012 .

[23]  Raimond Grimberg,et al.  Nondestructive evaluation of the severity of discontinuities in flat conductive materials by an eddy-current transducer with orthogonal coils , 2000 .

[24]  Wei Li,et al.  Noncontact Thickness Measurement of Metal Films Using Eddy-Current Sensors Immune to Distance Variation , 2015, IEEE Transactions on Instrumentation and Measurement.

[25]  David L. Atherton,et al.  A study of magnetic flux-leakage signals , 1998 .

[26]  S K Burke A perturbation method for calculating coil impedance in eddy-current testing , 1985 .

[27]  A. V. Sukhikh,et al.  Application of the magnetic saturation method for eddy-current inspection of spent fuel elements from fast reactors , 2007 .

[28]  Young Joo Kim,et al.  Eddy current test of steel tube employing electromagnet technique for dc magnetization , 1986 .

[29]  Jiuhao Ge,et al.  Circumferential current field testing system with TMR sensor array for non-contact detection and estimation of cracks on power plant piping , 2017 .

[30]  Peng Xu,et al.  A new differential eddy current testing sensor used for detecting crack extension direction , 2011 .

[31]  Yihua Kang,et al.  Effects of surface roughness on magnetic flux leakage testing of micro-cracks , 2017 .

[32]  K. Koyama,et al.  INFLUENCE OF SPEED EFFECT IN EDDY CURRENT NONDESTRUCTIVE TESTING , 1992 .

[33]  Z. You,et al.  Combining eddy current and magnetic flux leakage for tank floor inspection , 1994 .

[34]  B. Kaplan,et al.  DC magnetic field sensor employing multifield eddy-current effects , 1988 .

[35]  O. Stupakov,et al.  Magnetic adaptive testing—low magnetization, high sensitivity assessment of material modifications , 2006 .

[36]  Analytical solution in eddy-current testing of double-layer media with depth-varying magnetic properties , 1991 .

[37]  Yihua Kang,et al.  Magnetic mechanisms of magnetic flux leakage nondestructive testing , 2013 .

[38]  O. Kronenwerth,et al.  Low-noise magnetic-flux sensors based on the extraordinary magnetoresistance effect , 2004 .

[39]  Viresh Wickramasinghe,et al.  Sensitivity of Air-Coupled Ultrasound and Eddy Current Sensors to Bearing Fault Detection , 2008 .

[40]  Yihua Kang,et al.  A Permeability-Measuring Magnetic Flux Leakage Method for Inner Surface Crack in Thick-Walled Steel Pipe , 2017 .

[41]  Shengbo Jiao,et al.  Sensitivity boost of rosette eddy current array sensor for quantitative monitoring crack , 2016 .

[42]  N. Takahashi,et al.  Evaluation of Detecting Method With AC and DC Excitations of Opposite-Side Defect in Steel Using 3-D Nonlinear FEM Taking the Minor Loop Into Account , 2008, IEEE Transactions on Magnetics.

[43]  Helena Geirinhas Ramos,et al.  Automatic parameter selection for Tikhonov regularization in ECT Inverse problem , 2016 .

[44]  Nathan Ida Modeling of velocity effects in eddy current applications , 1988 .

[45]  Y. Le Bihan,et al.  Lift-off and tilt effects on eddy current sensor measurements: a 3-D finite element study , 2002 .

[46]  Buzz Wincheski,et al.  Study of the new eddy current non-destructive testing sensor on ferromagnetic materials , 1994 .

[47]  Yihua Kang,et al.  A new MFL principle and method based on near-zero background magnetic field , 2010 .

[48]  Kai Xu,et al.  A Novel Triple-Coil Electromagnetic Sensor for Thickness Measurement Immune to Lift-Off Variations , 2016, IEEE Transactions on Instrumentation and Measurement.