Feasibility of Real-Time Magnetic Resonance Imaging for Catheter Guidance in Electrophysiology Studies

Background— Compared with fluoroscopy, the current imaging standard of care for guidance of electrophysiology procedures, magnetic resonance imaging (MRI) provides improved soft-tissue resolution and eliminates radiation exposure. However, because of inherent magnetic forces and electromagnetic interference, the MRI environment poses challenges for electrophysiology procedures. In this study, we sought to test the feasibility of performing electrophysiology studies with real-time MRI guidance. Methods and Results— An MRI-compatible electrophysiology system was developed. Catheters were targeted to the right atrium, His bundle, and right ventricle of 10 mongrel dogs (23 to 32 kg) via a 1.5-T MRI system using rapidly acquired fast gradient-echo images (≈5 frames per second). Catheters were successfully positioned at the right atrial, His bundle, and right ventricular target sites of all animals. Comprehensive electrophysiology studies with recording of intracardiac electrograms and atrial and ventricular pacing were performed. Postprocedural pathological evaluation revealed no evidence of thermal injury to the myocardium. After proof of safety in animal studies, limited real-time MRI-guided catheter mapping studies were performed in 2 patients. Adequate target catheter localization was confirmed via recording of intracardiac electrograms in both patients. Conclusions— To the best of our knowledge, this is the first study to report the feasibility of real-time MRI-guided electrophysiology procedures. This technique may eliminate patient and staff radiation exposure and improve real-time soft tissue resolution for procedural guidance.

[1]  Raymond J Kim,et al.  Infarct morphology identifies patients with substrate for sustained ventricular tachycardia. , 2005, Journal of the American College of Cardiology.

[2]  Hugh Calkins,et al.  Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging. , 2006, Journal of the American College of Cardiology.

[3]  R. Mitrani,et al.  Comparison of Laplacian and Bipolar ECGs for R-wave Detection during Noise , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Warren J Manning,et al.  Magnetic Resonance–Guided Coronary Artery Stent Placement in a Swine Model , 2002, Circulation.

[5]  R. Frayne,et al.  Minimizing interference from magnetic resonance imagers during electrocardiography , 1998, IEEE Transactions on Biomedical Engineering.

[6]  H Calkins,et al.  Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging. , 2000, Circulation.

[7]  Jeffrey L Duerk,et al.  The catheter-driven MRI scanner: a new approach to intravascular catheter tracking and imaging-parameter adjustment for interventional MRI. , 2004, AJR. American journal of roentgenology.

[8]  H. Halperin,et al.  Clinical Utility and Safety of a Protocol for Noncardiac and Cardiac Magnetic Resonance Imaging of Patients With Permanent Pacemakers and Implantable-Cardioverter Defibrillators at 1.5 Tesla , 2006, Circulation.

[9]  Wolfhard Semmler,et al.  Active catheter tracking using parallel MRI and real‐time image reconstruction , 2006, Magnetic resonance in medicine.

[10]  Ergin Atalar,et al.  Multifunctional interventional devices for MRI: A combined electrophysiology/MRI catheter , 2002, Magnetic resonance in medicine.

[11]  D. Praticò,et al.  Effect of Low-Dose Aspirin on Vascular Inflammation, Plaque Stability, and Atherogenesis in Low-Density Lipoprotein Receptor–Deficient Mice , 2002, Circulation.

[12]  I. Young,et al.  Induction of microcurrents in critically ill patients in magnetic resonance systems , 1993, Critical care medicine.

[13]  Harold Litt,et al.  Strategy for Safe Performance of Extrathoracic Magnetic Resonance Imaging at 1.5 Tesla in the Presence of Cardiac Pacemakers in Non–Pacemaker-Dependent Patients: A Prospective Study With 115 Examinations , 2006, Circulation.

[14]  David Schwartzman,et al.  On the accuracy of CartoMerge for guiding posterior left atrial ablation in man. , 2007, Heart rhythm.

[15]  Jonathan M Sorger,et al.  Catheter-Based Endomyocardial Injection With Real-Time Magnetic Resonance Imaging , 2002, Circulation.

[16]  J. Lewin,et al.  MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects. , 2005, Magnetic resonance imaging clinics of North America.

[17]  W. Nitz,et al.  On the heating of linear conductive structures as guide wires and catheters in interventional MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[18]  Michael Jerosch-Herold,et al.  Magnetic Resonance Image-Guided Transcatheter Closure of Atrial Septal Defects , 2003, Circulation.

[19]  Tobias Schaeffter,et al.  Magnetic Resonance–Guided Placement of Atrial Septal Closure Device in Animal Model of Patent Foramen Ovale , 2002, Circulation.

[20]  José Jalife,et al.  Reentry and atrial fibrillation. , 2007, Heart rhythm.

[21]  R. Günther,et al.  MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs. , 2005, Radiology.

[22]  Robert G. Weiss,et al.  Magnetic Resonance Assessment of the Substrate for Inducible Ventricular Tachycardia in Nonischemic Cardiomyopathy , 2005, Circulation.

[23]  J M Peeters,et al.  Development and testing of passive tracking markers for different field strengths and tracking speeds , 2006, Physics in medicine and biology.

[24]  D. Pennell,et al.  Late Gadolinium Enhancement Cardiovascular Magnetic Resonance of the Systemic Right Ventricle in Adults With Previous Atrial Redirection Surgery for Transposition of the Great Arteries , 2005, Circulation.