Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.

BACKGROUND Many clinical observations have shown that immediate loading is indicated when the stabilization of the bone/implant is optimal and when the estimated loads are not excessively high. Nonetheless, more experimental studies are needed to consider the immediate loading protocol as a safe procedure. Mechanical analysis using the finite element (FE) method analysis has been employed by many authors to understand the biomechanical behavior around dental implants. PURPOSE This study was to evaluate the effect of the diameter and length on the stress and strain distribution of the crestal bone around implants under immediate loading. MATERIALS AND METHODS By an ad hoc automatic mesh generator, high-quality FE models of complete range mandible was constructed from computer tomography, with three Straumann (Straumann Institute, Waldenburg, Switzerland) implants of various sizes embedded in the anterior zone. The implant diameter ranged from 3.3 to 4.8 mm, and length ranged from 6 to 14 mm, resulting in seven designs. The implant-bone interface was simulated by nonlinear frictional contact algorithm. For each design, vertical and oblique loadings of 150 N were applied, respectively, to each implant, and stresses and strains in the surrounding cortical bone were evaluated. RESULTS The biomechanics analysis provided results that the oblique loading would induce significantly higher interfacial stresses and strains than the vertical loading, while the intergroup stress difference significant levels was evaluated using t-tests method and the level of significance (.05) that was accepted for significance. Under both loadings, the maximal values were recorded in the 3.3 (diameter) x 10 (length) mm implant configuration, whose mean and peak values were both higher than that of others with significant statistical differences. The second maximal one is 4.1 x 6 mm configuration, and the minimal stresses were recorded in 4.8 x 10 mm configuration, whose strains were also near to lowest. CONCLUSIONS Increasing the diameter and length of the implant decreased the stress and strain on the alveolar crest, and the stress and strain values notably increased under buccolingual loading as compared with vertical loading, but diameter had a more significant effect than length to relieve the crestal stress and strain concentration.

[1]  B Rangert,et al.  Influence of implant diameters on the integration of screw implants. An experimental study in rabbits. , 1997, International journal of oral and maxillofacial surgery.

[2]  J B Brunski,et al.  Biomechanics of oral implants: future research directions. , 1988, Journal of dental education.

[3]  F. Isidor,et al.  Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. , 1996, Clinical oral implants research.

[4]  George A Zarb,et al.  Implant prosthodontic management of partially edentulous patients missing posterior teeth: the Toronto experience. , 2003, The Journal of prosthetic dentistry.

[5]  Holmes Dc,et al.  Influence of bone quality on stress distribution for endosseous implants. , 1997 .

[6]  J. Kuiper,et al.  Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. , 1992, The Journal of prosthetic dentistry.

[7]  G. van der Perre,et al.  Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. , 1998, Journal of oral rehabilitation.

[8]  U C Belser,et al.  Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. , 2004, Clinical oral implants research.

[9]  Dinçer Bozkaya,et al.  Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis. , 2004, The Journal of prosthetic dentistry.

[10]  Haruka Kusakari,et al.  Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.

[11]  G. Zarb,et al.  Treatment outcomes of patients with implant-supported fixed partial prostheses. , 1998, The International journal of oral & maxillofacial implants.

[12]  F. Mante,et al.  Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. , 1998, The Journal of oral implantology.

[13]  S Winkler,et al.  Implant survival to 36 months as related to length and diameter. , 2000, Annals of periodontology.

[14]  O. Miyakawa,et al.  Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. , 1998, The International journal of oral & maxillofacial implants.

[15]  James Laney Williams,et al.  Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. , 2005, Clinical oral implants research.

[16]  H. Chun,et al.  Evaluation of design parameters of osseointegrated dental implants using finite element analysis. , 2002, Journal of oral rehabilitation.

[17]  M Davarpanah,et al.  Wide-diameter implants: new concepts. , 2001, The International journal of periodontics & restorative dentistry.

[18]  D Pipko,et al.  Three-dimensional finite element stress analysis in and around the Screw-Vent implant. , 1991, The International journal of oral & maxillofacial implants.

[19]  L Sennerby,et al.  Influence of variations in implant diameters: a 3- to 5-year retrospective clinical report. , 1999, The International journal of oral & maxillofacial implants.

[20]  G. Liu,et al.  Application of finite element analysis in implant dentistry: a review of the literature. , 2001, The Journal of prosthetic dentistry.

[21]  M R Rieger,et al.  Finite element analysis of six endosseous implants. , 1990, The Journal of prosthetic dentistry.

[22]  C H Jooste,et al.  Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses. , 1995, The International journal of oral & maxillofacial implants.

[23]  Makoto Shiota,et al.  The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures. , 2004, The Journal of prosthetic dentistry.

[24]  H. Iplikçioğlu,et al.  Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. , 2002, Journal of dentistry.

[25]  G. Douglass,et al.  The immediate dental implant. , 2002, Journal of the California Dental Association.

[26]  S C Bayne,et al.  3D-FEA of osseointegration percentages and patterns on implant-bone interfacial stresses. , 1997, Journal of dentistry.

[27]  H. Iplikçioğlu,et al.  Finite element stress analysis of the influence of staggered versus straight placement of dental implants. , 2001, The International journal of oral & maxillofacial implants.

[28]  Lum Lb,et al.  A biomechanical rationale for the use of short implants. , 1991 .

[29]  Afonso C. C. Lemonge,et al.  Three-dimensional finite element stress analysis of a cuneiform-geometry implant. , 2003, The International journal of oral & maxillofacial implants.

[30]  R. Palmer,et al.  A prospective study of Astra single tooth implants. , 1997, Clinical oral implants research.

[31]  C M Cobb,et al.  Loss of crestal bone around dental implants: a retrospective study. , 1998, Implant dentistry.

[32]  John B. Brunski,et al.  In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface , 1999, Advances in dental research.

[33]  Y. Çiftçi,et al.  The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations. , 2000, The International journal of oral & maxillofacial implants.

[34]  K. Akca,et al.  Evaluation of the Effect of the Residual Bone Angulation on Implant-Supported Fixed Prosthesis in Mandibular Posterior Edentulism Part II: 3-D Finite Element Stress Analysis , 2001, Implant dentistry.

[35]  Steven E Eckert,et al.  Survey of implant experience by prosthodontists in the United States. , 2002, Journal of prosthodontics : official journal of the American College of Prosthodontists.