Calibrated fMRI for dynamic mapping of CMRO2 responses using MR-based measurements of whole-brain venous oxygen saturation

Functional MRI (fMRI) can identify active foci in response to stimuli through BOLD signal fluctuations, which represent a complex interplay between blood flow and cerebral metabolic rate of oxygen (CMRO2) changes. Calibrated fMRI can disentangle the underlying contributions, allowing quantification of the CMRO2 response. Here, whole-brain venous oxygen saturation (Y v ) was computed alongside ASL-measured CBF and BOLD-weighted data to derive the calibration constant, M, using the proposed Y v -based calibration. Data were collected from 10 subjects at 3T with a three-part interleaved sequence comprising background-suppressed 3D-pCASL, 2D BOLD-weighted, and single-slice dual-echo GRE (to measure Y v via susceptometry-based oximetry) acquisitions while subjects breathed normocapnic/normoxic, hyperoxic, and hypercapnic gases, and during a motor task. M was computed via Y v -based calibration from both hypercapnia and hyperoxia stimulus data, and results were compared to conventional hypercapnia or hyperoxia calibration methods. Mean M in gray matter did not significantly differ between calibration methods, ranging from 8.5 ± 2.8% (conventional hyperoxia calibration) to 11.7 ± 4.5% (Yv-based calibration in response to hyperoxia), with hypercapnia-based M values between (p = 0.56). Relative CMRO2 changes from finger tapping were computed from each M map. CMRO2 increased by ∼20% in the motor cortex, and good agreement was observed between the conventional and proposed calibration methods.

[1]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[2]  Eitan Prisman,et al.  Comparison of the effects of independently‐controlled end‐tidal PCO2 and PO2 on blood oxygen level–dependent (BOLD) MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[3]  Egill Rostrup,et al.  Determination of relative CMRO2 from CBF and BOLD changes: Significant increase of oxygen consumption rate during visual stimulation , 1999, Magnetic resonance in medicine.

[4]  M. Raichle,et al.  The Effects of Changes in PaCO2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit Time , 1974, Stroke.

[5]  Peter Jezzard,et al.  Comparison of hypercapnia‐based calibration techniques for measurement of cerebral oxygen metabolism with MRI , 2009, Magnetic resonance in medicine.

[6]  Jeremy F Magland,et al.  Retrospective correction for induced magnetic field inhomogeneity in measurements of large‐vessel hemoglobin oxygen saturation by MR susceptometry , 2009, Magnetic resonance in medicine.

[7]  J. Detre,et al.  Whole-brain background-suppressed pCASL MRI with 1D-accelerated 3D RARE Stack-Of-Spirals readout , 2017, PloS one.

[8]  William J Powers,et al.  Effect of hyperoxia on cerebral metabolic rate for oxygen measured using positron emission tomography in patients with acute severe head injury. , 2007, Journal of neurosurgery.

[9]  Sungho Tak,et al.  Quantification of CMRO2 without hypercapnia using simultaneous near-infrared spectroscopy and fMRI measurements , 2010, Physics in medicine and biology.

[10]  J. Severinghaus Simple, accurate equations for human blood O2 dissociation computations. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[11]  Hanzhang Lu,et al.  Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI , 2008, Magnetic resonance in medicine.

[12]  Richard D. Hoge,et al.  Regional Reproducibility of BOLD Calibration Parameter M, OEF and Resting-State CMRO2 Measurements with QUO2 MRI , 2016, PloS one.

[13]  Ravinder Reddy,et al.  Absolute cerebral blood flow quantification with pulsed arterial spin labeling during hyperoxia corrected with the simultaneous measurement of the longitudinal relaxation time of arterial blood , 2012, Magnetic resonance in medicine.

[14]  Seong‐gi Kim Cmrr,et al.  Comparison of blood oxygenattion and cerebral blood flow effect in fMRI: Estimation of relative oxygen consumption change , 1997, Magnetic resonance in medicine.

[15]  Thomas T. Liu,et al.  Caffeine-induced uncoupling of cerebral blood flow and oxygen metabolism: A calibrated BOLD fMRI study , 2008, NeuroImage.

[16]  G. Crelier,et al.  Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: The deoxyhemoglobin dilution model , 1999, Magnetic resonance in medicine.

[17]  Maximilian Reiser,et al.  Oxygen‐enhanced MRI of the brain , 2002, Magnetic resonance in medicine.

[18]  Danny J. J. Wang,et al.  Measurement of Cerebral White Matter Perfusion Using Pseudocontinuous Arterial Spin Labeling 3T Magnetic Resonance Imaging – an Experimental and Theoretical Investigation of Feasibility , 2013, PloS one.

[19]  D. Yablonskiy,et al.  Quantitative BOLD: Mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: Default state , 2007, Magnetic resonance in medicine.

[20]  Richard G. Wise,et al.  Calibrated fMRI for mapping absolute CMRO2: Practicalities and prospects , 2019, NeuroImage.

[21]  Peiying Liu,et al.  Effect of Hypoxia and Hyperoxia on Cerebral Blood Flow, Blood Oxygenation, and Oxidative Metabolism , 2012, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[22]  Wen-Ming Luh,et al.  Gas-free calibrated fMRI with a correction for vessel-size sensitivity , 2018, NeuroImage.

[23]  Felix W Wehrli,et al.  MR susceptometry for measuring global brain oxygen extraction , 2006, Magnetic resonance in medicine.

[24]  Felix W. Wehrli,et al.  Calibrated bold fMRI with an optimized ASL-BOLD dual-acquisition sequence , 2016, NeuroImage.

[25]  T. L. Davis,et al.  Calibrated functional MRI: mapping the dynamics of oxidative metabolism. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[26]  Bing Wu,et al.  Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition , 2011, NeuroImage.

[27]  James Duffin,et al.  Prospective targeting and control of end‐tidal CO2 and O2 concentrations , 2007, The Journal of physiology.

[28]  Lutz Jäncke,et al.  Brain size and grey matter volume in the healthy human brain , 2002, Neuroreport.

[29]  G L Shulman,et al.  INAUGURAL ARTICLE by a Recently Elected Academy Member:A default mode of brain function , 2001 .

[30]  Felix W Wehrli,et al.  MRI Estimation of Global Brain Oxygen Consumption Rate , 2010, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[31]  G. Zaharchuk,et al.  Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. , 2015, Magnetic resonance in medicine.

[32]  Richard Wise,et al.  A calibration method for quantitative BOLD fMRI based on hyperoxia , 2007, NeuroImage.

[33]  T. Satoh,et al.  Effects of propofol on cerebral blood flow and the metabolic rate of oxygen in humans , 2002, Acta anaesthesiologica Scandinavica.

[34]  Jeroen Hendrikse,et al.  In vivo quantification of hyperoxic arterial blood water T1 , 2015, NMR in biomedicine.

[35]  Pascal Spincemaille,et al.  Quantitative mapping of cerebral metabolic rate of oxygen (CMRO2) using quantitative susceptibility mapping (QSM) , 2015, Magnetic resonance in medicine.

[36]  Jeremy F Magland,et al.  Accuracy of the cylinder approximation for susceptometric measurement of intravascular oxygen saturation , 2012, Magnetic resonance in medicine.

[37]  Richard B. Buxton,et al.  A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: Comparison of a new approach with existing methods , 2012, NeuroImage.

[38]  R. Hoge,et al.  A generalized procedure for calibrated MRI incorporating hyperoxia and hypercapnia , 2013, Human brain mapping.

[39]  J Duffin,et al.  The cerebrovascular response to carbon dioxide in humans , 2011, The Journal of physiology.

[40]  Richard G. Wise,et al.  Measurement of OEF and absolute CMRO2: MRI-based methods using interleaved and combined hypercapnia and hyperoxia , 2013, NeuroImage.

[41]  Richard B. Buxton,et al.  Prospects for quantitative fMRI: Investigating the effects of caffeine on baseline oxygen metabolism and the response to a visual stimulus in humans , 2011, NeuroImage.

[42]  Xavier Golay,et al.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla , 2004, Magnetic resonance in medicine.

[43]  Timothy Q. Duong,et al.  Effects of hypoxia, hyperoxia, and hypercapnia on baseline and stimulus-evoked BOLD, CBF, and CMRO2 in spontaneously breathing animals , 2005, NeuroImage.

[44]  B R Rosen,et al.  Mr contrast due to intravascular magnetic susceptibility perturbations , 1995, Magnetic resonance in medicine.

[45]  J. Jean Chen,et al.  Comparing cerebrovascular reactivity measured using BOLD and cerebral blood flow MRI: The effect of basal vascular tension on vasodilatory and vasoconstrictive reactivity , 2015, NeuroImage.

[46]  Richard B. Buxton,et al.  Reproducibility of BOLD, perfusion, and CMRO2 measurements with calibrated-BOLD fMRI , 2007, NeuroImage.

[47]  P. Rasmussen,et al.  Acute hypoxia increases the cerebral metabolic rate – a magnetic resonance imaging study , 2015, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[48]  Susan T. Francis,et al.  Calibrated BOLD using direct measurement of changes in venous oxygenation , 2012, NeuroImage.

[49]  E. Haacke,et al.  Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime , 1994, Magnetic resonance in medicine.

[50]  J. J. Chen,et al.  Global Cerebral Oxidative Metabolism during Hypercapnia and Hypocapnia in Humans: Implications for BOLD fMRI , 2010, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[51]  Gary F. Egan,et al.  Using carbogen for calibrated fMRI at 7Tesla: Comparison of direct and modelled estimation of the M parameter , 2014, NeuroImage.

[52]  D. Alsop,et al.  Optimization of background suppression for arterial spin labeling perfusion imaging , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[53]  D Comar,et al.  Regional Cerebral Blood Flow and Oxygen Consumption in Human Aging , 1984, Stroke.

[54]  Pascal Spincemaille,et al.  Cerebral metabolic rate of oxygen (CMRO2) mapping with hyperventilation challenge using quantitative susceptibility mapping (QSM) , 2017, Magnetic resonance in medicine.

[55]  Peter Jezzard,et al.  Cerebral Perfusion Response to Hyperoxia , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[56]  P. Jezzard,et al.  Quantitative measurement of cerebral physiology using respiratory-calibrated MRI , 2012, NeuroImage.

[57]  Claudine Joëlle Gauthier,et al.  Absolute quantification of resting oxygen metabolism and metabolic reactivity during functional activation using QUO2 MRI , 2012, NeuroImage.

[58]  J. J. van Vaals,et al.  “Keyhole” method for accelerating imaging of contrast agent uptake , 1993, Journal of magnetic resonance imaging : JMRI.

[59]  David J. Dubowitz,et al.  Calibrating the BOLD response without administering gases: Comparison of hypercapnia calibration with calibration using an asymmetric spin echo , 2015, NeuroImage.

[60]  Jeremy F Magland,et al.  Rapid magnetic resonance measurement of global cerebral metabolic rate of oxygen consumption in humans during rest and hypercapnia , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[61]  R R Edelman,et al.  Effect of oxygen inhalation on relaxation times in various tissues , 1997, Journal of magnetic resonance imaging : JMRI.

[62]  D. Yablonskiy,et al.  Water proton MR properties of human blood at 1.5 Tesla: Magnetic susceptibility, T1, T2, T  *2 , and non‐Lorentzian signal behavior , 2001, Magnetic resonance in medicine.

[63]  Felix W Wehrli,et al.  Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification , 2012, Magnetic resonance in medicine.

[64]  Jeremy Magland,et al.  High temporal resolution in vivo blood oximetry via projection‐based T2 measurement , 2013, Magnetic resonance in medicine.

[65]  Claudine Joëlle Gauthier,et al.  Elimination of visually evoked BOLD responses during carbogen inhalation: Implications for calibrated MRI , 2011, NeuroImage.

[66]  Peter Herman,et al.  Quantitative β mapping for calibrated fMRI , 2016, NeuroImage.

[67]  Felix W. Wehrli,et al.  Interleaved quantitative BOLD: Combining extravascular R2ʹ - and intravascular R2-measurements for estimation of deoxygenated blood volume and hemoglobin oxygen saturation , 2018, NeuroImage.

[68]  Zachary B. Rodgers,et al.  High Temporal Resolution MRI Quantification of Global Cerebral Metabolic Rate of Oxygen Consumption in Response to Apneic Challenge , 2013, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[69]  Richard B. Buxton,et al.  A theoretical framework for estimating cerebral oxygen metabolism changes using the calibrated-BOLD method: Modeling the effects of blood volume distribution, hematocrit, oxygen extraction fraction, and tissue signal properties on the BOLD signal , 2011, NeuroImage.