Development of a Novel Heart Rate Synchronized Pulsatile Left Ventricular Assist Device

The left ventricular assist device (LVADs) have been used as either a bridge to transplant or destination therapy for end stage heart failure. The continuous-flow models have been used with multiple complications. This project applied electromagnetically driven pump to the development of a heart-rate synchronized pulsatile LVAD. A control system was developed based on LabVIEW programming platform. The LabVIEW program receives pulse signals by DAQ device and then output the signal to control the coil of the pump by DAQ device. Under the action of the magnetic effect of electric current, thus the magnetic piston inside the pump is pushed back and forth. The program not only receives pulse signals but also synchronizes the pump and pulsation. The researchers used heart mock to test the flow situation of water. According to the current situation, the pump can affect the water flow. Currently, the experiment enters the stage that cooperates with Keelung Chang Gung Memorial Hospital. In addition, the circuit is miniaturized and the connector is used for experimental convenience in the hospital in the future.

[1]  Nir Uriel,et al.  Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon. , 2014, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[2]  M C Oz,et al.  Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.

[3]  Ramon Luengo-Fernandez,et al.  European Cardiovascular Disease Statistics 2017 , 2012 .

[4]  M. Slaughter,et al.  Hospital costs for left ventricular assist devices for destination therapy: lower costs for implantation in the post-REMATCH era. , 2006, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  M. Ruel,et al.  Centrifugal pump and roller pump in adult cardiac surgery: a meta-analysis of randomized controlled trials. , 2012, Artificial organs.

[6]  J. Rogers,et al.  Outcomes After Implantable Left Ventricular Assist Device Replacement Procedures , 2014, ASAIO journal.

[7]  Robert L Kormos,et al.  Sixth INTERMACS annual report: a 10,000-patient database. , 2014, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[8]  Ranjit John,et al.  Gastrointestinal bleed after left ventricular assist device implantation: incidence, management, and prevention. , 2014, Annals of cardiothoracic surgery.