Performance characterization of microtomography with complementary metal-oxide-semiconductor detectors for computer-aided defect inspection

We developed a computer-aided defect inspection system based on computed tomography (CT). The system consists of a homemade small cone-beam CT (CBCT) system and a graphical toolbox, which is used to extract a computer-aided design (CAD) model from the CT data. In the small CBCT system, the x-ray imaging detector is based on a complementary metal-oxide-semiconductor photodiode array in conjunction with a scintillator. Imaging performance of the detector was evaluated in terms of modulation-transfer function, noise-power spectrum, and detective quantum efficiency. The tomographic imaging performance of the small CBCT system was evaluated in terms of signal-to-noise ratio and contrast-to-noise ratio. The graphical toolbox to support defect inspection incorporates various functional tools such as volume rendering, segmentation, triangular-mesh data generation, and data reduction. All the tools have been integrated in a graphical-user interface form. The developed system can provide rapid visual inspection as ...

[1]  H H Barrett,et al.  Statistical limitations in transaxial tomography. , 1976, Computers in biology and medicine.

[2]  Min Hyoung Cho,et al.  A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. , 2003, Physics in medicine and biology.

[3]  Ehsan Samei,et al.  An experimental comparison of detector performance for direct and indirect digital radiography systems. , 2003, Medical physics.

[4]  W. Kalender X-ray computed tomography , 2006, Physics in medicine and biology.

[5]  Min Kook Cho,et al.  Characterization of CMOS Pixel Detectors for Digital X-Ray Imaging , 2006 .

[6]  K. Rossmann,et al.  Modulation Transfer Function of Radiographic Systems Using Fluorescent Screens , 1962 .

[7]  Ho Kyung Kim,et al.  Computational Toolset for X-Ray Spectral Analysis , 2006 .

[8]  Richard L. Van Metter,et al.  Handbook of Medical Imaging , 2009 .

[9]  Min Kook Cho,et al.  Measurements of X-ray Imaging Performance of Granular Phosphors With Direct-Coupled CMOS Sensors , 2008, IEEE Transactions on Nuclear Science.

[10]  B. Flannery,et al.  Three-Dimensional X-ray Microtomography , 1987, Science.

[11]  Ho Kyung Kim Generalized cascaded model to assess noise transfer in scintillator-based x-ray imaging detectors , 2006 .

[12]  E. Samei,et al.  Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. , 1999, Medical physics.

[13]  Roberto Cesareo,et al.  Computed tomography with image intensifier: potential use for nondestructive testing and imaging of small objects , 2000 .

[14]  Qihua Zhao,et al.  Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors. , 2009, Medical physics.

[15]  Sasov,et al.  Desktop X‐ray microscopy and microtomography , 1998, Journal of microscopy.

[16]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[17]  P. Rüegsegger,et al.  A microtomographic system for the nondestructive evaluation of bone architecture , 2006, Calcified Tissue International.

[18]  Thorsten Graeve,et al.  High-resolution CMOS imaging detector , 2001, SPIE Medical Imaging.

[19]  Myung Hye Cho,et al.  Development and Characterization of a Flat-Panel Detector-Based Microtomography System , 2004 .

[20]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[21]  W W Peppler,et al.  Use of a slit camera for MTF measurements. , 1999, Medical physics.

[22]  Kyle J Myers,et al.  Lubberts effect in columnar phosphors. , 2004, Medical physics.

[23]  G. N. Ramachandran,et al.  Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms. , 1971, Proceedings of the National Academy of Sciences of the United States of America.

[24]  Gyuseong Cho,et al.  Use of a flat-panel detector for microtomography: a feasibility study for small-animal imaging , 2005 .

[25]  C. Neubauer,et al.  Intelligent X-ray inspection for quality control of solder joints , 1997 .

[26]  Chee Kai Chua,et al.  Rapid Prototyping Applications in Medicine. Part 2: STL File Generation and Case Studies , 2001 .

[27]  J. Hofmann,et al.  A wall-thickness-based method of adaptive integration time determination for X-ray computed tomography , 2006 .

[28]  Andreas Pommert,et al.  Investigation of medical 3D-rendering algorithms , 1990, IEEE Computer Graphics and Applications.

[29]  A Fenster,et al.  A high-resolution XRII-based quantitative volume CT scanner. , 1993, Medical physics.

[30]  P S Cho,et al.  Cone-beam CT from width-truncated projections. , 1996, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[31]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[32]  G. Lubberts,et al.  Random Noise Produced by X-Ray Fluorescent Screens* , 1968 .