Enantioselective ultra high performance liquid and supercritical fluid chromatography: The race to the shortest chromatogram.

The ever-increasing need for enantiomerically pure chiral compounds has greatly expanded the number of enantioselective separation methods available for the precise and accurate measurements of the enantiomeric purity. The introduction of chiral stationary phases for liquid chromatography in the last decades has revolutionized the routine methods to determine enantiomeric purity of chiral drugs, agrochemicals, fragrances, and in general of organic and organometallic compounds. In recent years, additional efforts have been placed on faster, enantioselective analytical methods capable to fulfill the high throughput requirements of modern screening procedures. Efforts in this field, capitalizing on improved chromatographic particle technology and dedicated instrumentation, have led to highly efficient separations that are routinely completed on the seconds time scale. An overview of the recent achievements in the field of ultra-high-resolution chromatography on column packed with chiral stationary phases, both based on sub-2 μm fully porous and sub-3 μm superficially porous particles, will be given, with an emphasis on very recent studies on ultrafast chiral separations.

[1]  G. Bellazzi,et al.  Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance. , 2010, Journal of chromatography. A.

[2]  T. Berger,et al.  Instrumental Idiosyncrasies Affecting the Performance of Ultrafast Chiral and Achiral Sub/Supercritical Fluid Chromatography. , 2016, Analytical chemistry.

[3]  Y. Okamoto,et al.  Very Fast Enantioseparation in High-performance Liquid Chromatography Using Cellulose Tris(3,5-dimethylphenylcarbamate) Coated on Monolithic Silica Support , 2003 .

[4]  Davy Guillarme,et al.  The use of columns packed with sub-2 µm particles in supercritical fluid chromatography , 2014 .

[5]  T. Farkas,et al.  Comparative high-performance liquid chromatography enantioseparations on polysaccharide based chiral stationary phases prepared by coating totally porous and core-shell silica particles. , 2012, Journal of chromatography. A.

[6]  D. Armstrong,et al.  Superficially Porous Particle Based Hydroxypropyl-β-cyclodextrin Stationary Phase for High-Efficiency Enantiomeric Separations. , 2015, Chirality.

[7]  F. Gasparrini,et al.  Experimental evidence of the kinetic performance achievable with columns packed with new 1.9μm fully porous particles of narrow particle size distribution. , 2016, Journal of chromatography. A.

[8]  F. Gasparrini,et al.  Ultra-fast high-efficiency enantioseparations by means of a teicoplanin-based chiral stationary phase made on sub-2 μm totally porous silica particles of narrow size distribution. , 2016, Journal of chromatography. A.

[9]  D. Belder,et al.  Chip-based high-performance liquid chromatography for high-speed enantioseparations. , 2015, Analytical chemistry.

[10]  F. Gasparrini,et al.  Future perspectives in high efficient and ultrafast chiral liquid chromatography through zwitterionic teicoplanin-based 2-μm superficially porous particles. , 2017, Journal of chromatography. A.

[11]  C. Welch,et al.  Pushing the speed limit in enantioselective supercritical fluid chromatography. , 2015, Journal of separation science.

[12]  F. Gasparrini,et al.  Expanding the potential of chiral chromatography for high-throughput screening of large compound libraries by means of sub-2μm Whelk-O 1 stationary phase in supercritical fluid conditions. , 2015, Journal of chromatography. A.

[13]  G. Guiochon,et al.  Particle size distribution and column efficiency. An ongoing debate revived with 1.9μm Titan-C18 particles. , 2014, Journal of chromatography. A.

[14]  F. Gasparrini,et al.  Introducing enantioselective ultrahigh-pressure liquid chromatography (eUHPLC): theoretical inspections and ultrafast separations on a new sub-2-μm Whelk-O1 stationary phase. , 2012, Analytical chemistry.

[15]  L. Zhang,et al.  Teicoplanin bonded sub-2 μm superficially porous particles for enantioseparation of native amino acids. , 2015, Journal of pharmaceutical and biomedical analysis.

[16]  Frank Glorius,et al.  Contemporary screening approaches to reaction discovery and development. , 2014, Nature chemistry.

[17]  D. Armstrong,et al.  Comparison of superficially porous and fully porous silica supports used for a cyclofructan 6 hydrophilic interaction liquid chromatographic stationary phase. , 2014, Journal of chromatography. A.

[18]  F. Gasparrini,et al.  Enantioseparation by ultra-high-performance liquid chromatography , 2014 .

[19]  Christopher J. Welch,et al.  MISER chromatography (multiple injections in a single experimental run): the chromatogram is the graph , 2010 .

[20]  G. Guiochon,et al.  The rationale for the optimum efficiency of columns packed with new 1.9μm fully porous Titan-C18 particles-a detailed investigation of the intra-particle diffusivity. , 2014, Journal of Chromatography A.

[21]  M. Lee,et al.  Separation of chiral pharmaceuticals using ultrahigh pressure liquid chromatography , 2002 .

[22]  Christopher J. Welch,et al.  Ultrafast chiral separations for high throughput enantiopurity analysis. , 2017, Chemical communications.

[23]  J. Veuthey,et al.  Fast chiral separation of drugs using columns packed with sub-2 microm particles and ultra-high pressure. , 2009, Chirality.

[24]  Kendall N Houk,et al.  Rapid catalyst identification for the synthesis of the pyrimidinone core of HIV integrase inhibitors. , 2012, Angewandte Chemie.

[25]  P. Schmitt‐Kopplin,et al.  Enantioseparation and selective detection of D-amino acids by ultra-high-performance liquid chromatography/mass spectrometry in analysis of complex biological samples. , 2014, Journal of chromatography. A.

[26]  F. Gasparrini,et al.  Recent advancements and future directions of superficially porous chiral stationary phases for ultrafast high-performance enantioseparations. , 2017, The Analyst.

[27]  D. Armstrong,et al.  High efficiency, narrow particle size distribution, sub-2 μm based macrocyclic glycopeptide chiral stationary phases in HPLC and SFC. , 2015, Analytica chimica acta.

[28]  J. Fekete,et al.  Facts and myths about columns packed with sub-3 microm and sub-2 microm particles. , 2010, Journal of pharmaceutical and biomedical analysis.

[29]  R. Reischl,et al.  Chemoselective and enantioselective analysis of proteinogenic amino acids utilizing N-derivatization and 1-D enantioselective anion-exchange chromatography in combination with tandem mass spectrometric detection. , 2011, Journal of chromatography. A.

[30]  J. Fekete,et al.  Fast liquid chromatography: the domination of core-shell and very fine particles. , 2012, Journal of chromatography. A.

[31]  A. Mazzanti,et al.  3,5-Dinitrobenzoyl-9-amino-9-deoxy-9-epiquinine as Pirkle-Anion Exchange Hybrid-Type Chiral Selector in High-Performance Liquid Chromatography , 2017, Chromatographia.

[32]  M Farooq Wahab,et al.  Sampling frequency, response times and embedded signal filtration in fast, high efficiency liquid chromatography: A tutorial. , 2016, Analytica chimica acta.

[33]  W. Schafer,et al.  Multiparallel microfluidic high-performance liquid chromatography for high-throughput normal-phase chiral analysis. , 2007, Journal of chromatography. A.

[34]  G. Roa‐Morales,et al.  UHPLC Determination of Enantiomeric Purity of Sertraline in the Presence of its Production Impurities , 2014, Chromatographia.

[35]  D. Armstrong,et al.  Quinine bonded to superficially porous particles for high-efficiency and ultrafast liquid and supercritical fluid chromatography. , 2017, Analytica chimica acta.

[36]  F. Gasparrini,et al.  Transition from enantioselective high performance to ultra-high performance liquid chromatography: A case study of a brush-type chiral stationary phase based on sub-5-micron to sub-2-micron silica particles. , 2010, Journal of chromatography. A.

[37]  Christopher J Welch,et al.  Overcoming "speed limits" in high throughput chromatographic analysis. , 2017, Journal of chromatography. A.

[38]  G. Guiochon,et al.  The current revolution in column technology: how it began, where is it going? , 2012, Journal of chromatography. A.

[39]  T. Berger Kinetic performance of a 50mm long 1.8μm chiral column in supercritical fluid chromatography. , 2016, Journal of chromatography. A.

[40]  Christopher J. Welch,et al.  9.02 High-Throughput Analysis for High-Throughput Experimentation in Organic Chemistry , 2014 .

[41]  T. Farkas,et al.  Further proof to the utility of polysaccharide-based chiral selectors in combination with superficially porous silica particles as effective chiral stationary phases for separation of enantiomers in high-performance liquid chromatography. , 2016, Journal of chromatography. A.

[42]  F. Gasparrini,et al.  Direct resolution in sub- and supercritical fluid chromatography on packed columns containing trans-1,2-diaminocyclohexane derivatives as selectors , 1993 .

[43]  Christopher J. Welch,et al.  Comparison of Multiparallel Microfluidic HPLC Instruments for High Throughput Analyses in Support of Pharmaceutical Process Research , 2006 .

[44]  D. Armstrong,et al.  Gone in seconds: praxis, performance, and peculiarities of ultrafast chiral liquid chromatography with superficially porous particles. , 2015, Analytical chemistry.

[45]  D. Armstrong,et al.  Advances in high-throughput and high-efficiency chiral liquid chromatographic separations. , 2016, Journal of chromatography. A.

[46]  F. Gasparrini,et al.  Enantioselective ultra-high and high performance liquid chromatography: a comparative study of columns based on the Whelk-O1 selector. , 2012, Journal of chromatography. A.

[47]  D. Armstrong,et al.  Ultrafast separation of fluorinated and desfluorinated pharmaceuticals using highly efficient and selective chiral selectors bonded to superficially porous particles. , 2015, Journal of chromatography. A.

[48]  S. Ng,et al.  Enantioseparation of dansyl amino acids by ultra-high pressure liquid chromatography using cationic β-cyclodextrins as chiral additives. , 2011, The Analyst.

[49]  F. Gasparrini,et al.  Pirkle-type chiral stationary phase on core-shell and fully porous particles: Are superficially porous particles always the better choice toward ultrafast high-performance enantioseparations? , 2016, Journal of chromatography. A.

[50]  C. Welch Are We Approaching a Speed Limit for the Chromatographic Separation of Enantiomers? , 2017, ACS central science.

[51]  D. Guillarme,et al.  Kinetic evaluation of new generation of column packed with 1.3 μm core-shell particles. , 2013, Journal of chromatography. A.

[52]  Koichi Inoue,et al.  Novel chiral derivatization reagents possessing a pyridylthiourea structure for enantiospecific determination of amines and carboxylic acids in high-throughput liquid chromatography and electrospray-ionization mass spectrometry for chiral metabolomics identification. , 2013, Journal of chromatography. A.

[53]  G. Guiochon,et al.  The quantitative impact of the mesopore size on the mass transfer mechanism of the new 1.9μm fully porous Titan-C18 particles. I: analysis of small molecules. , 2015, Journal of chromatography. A.

[54]  Mirlinda Biba,et al.  MISER chiral supercritical fluid chromatography for high throughput analysis of enantiopurity. , 2016, Journal of chromatography. A.

[55]  M Farooq Wahab,et al.  Salient Sub-Second Separations. , 2016, Analytical chemistry.

[56]  T. Berger Preliminary kinetic evaluation of an immobilized polysaccharide sub-2μm column using a low dispersion supercritical fluid chromatograph. , 2017, Journal of Chromatography A.

[57]  T. Toyo’oka,et al.  Determination of DL-amino acids, derivatized with R(-)-4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole, in nail of diabetic patients by UPLC-ESI-TOF-MS. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[58]  John F. Hartwig,et al.  A Simple, Multidimensional Approach to High-Throughput Discovery of Catalytic Reactions , 2011, Science.

[59]  T. Langlois,et al.  Fused core particles for HPLC columns , 2007 .

[60]  Kevin Bateman,et al.  Nanomole-scale high-throughput chemistry for the synthesis of complex molecules , 2015, Science.

[61]  J. Jorgenson Capillary liquid chromatography at ultrahigh pressures. , 2010, Annual review of analytical chemistry.

[62]  I. Aliagas,et al.  The evaluation of 25 chiral stationary phases and the utilization of sub-2.0μm coated polysaccharide chiral stationary phases via supercritical fluid chromatography. , 2013, Journal of chromatography. A.