A convenient, reliable, and fast acoustic pressure field measurement method for magnetic resonance-guided high-intensity focused ultrasound systems with phased array transducers

BackgroundWith the expanding applications of magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU), there is an urgent need for a convenient, reliable, and fast acoustic pressure field measurement method to aid treatment protocol design, ensure consistent and safe operation of the transducer, and facilitate regulatory approval of new techniques. Herein, we report a method for acoustic pressure field characterization of MR-HIFU systems with multi-element phased array transducers. This method integrates fiber-optic hydrophone measurements and electronic steering of the ultrasound beam with MRI-assisted HIFU focus alignment to the fiber tip.MethodsA clinical MR-HIFU system (Sonalleve V2, Profound Medical Inc., Mississauga, Canada) was used to assess the proposed method. A fiber-optic hydrophone was submerged in a degassed water bath, and the fiber tip location was traced using MRI. Subsequently, the nominal transducer focal point indicated on the MR-HIFU therapy planning software was positioned at the fiber tip, and the HIFU focus was electronically steered around the fiber tip within a 3D volume for 3D pressure field mapping, eliminating the need for an additional, expensive, and MRI-compatible 3D positioning stage. The peak positive and negative pressures were measured at the focus and validated using a standard hydrophone measurement setup outside the MRI magnet room.ResultsWe found that the initial MRI-assisted HIFU focus alignment had an average offset of 2.23 ± 1.33 mm from the fiber tip as identified by the 3D pressure field mapping. MRI guidance and electronic beam steering allowed 3D focus localization within ~ 1 h, i.e., faster than the typical time required using the standard laboratory setup (~ 3–4 h). Acoustic pressures measured using the proposed method were not significantly different from those obtained with the standard laboratory hydrophone measurements.ConclusionsIn conclusion, our method offers a convenient, reliable, and fast acoustic pressure field characterization tool for MR-HIFU systems with phased array transducers.

[1]  M. Platte,et al.  A polyvinylidene fluoride needle hydrophone for ultrasonic applications , 1985 .

[2]  C R Hill,et al.  Calibration of ultrasonic beams for bio-medical applications. , 1970, Physics in medicine and biology.

[3]  Arnaud Arvengas,et al.  Fiber optic probe hydrophone for the study of acoustic cavitation in water. , 2011, The Review of scientific instruments.

[4]  Ian Rivens,et al.  Quality assurance for clinical high intensity focused ultrasound fields , 2015, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[5]  Satya V. V. N. Kothapalli,et al.  Boiling histotripsy lesion characterization on a clinical magnetic resonance imaging-guided high intensity focused ultrasound system , 2017, PloS one.

[6]  Niels Kuster,et al.  A review of numerical and experimental compensation techniques for skull-induced phase aberrations in transcranial focused ultrasound , 2014, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[7]  Chris Diederich,et al.  MR-guided focused ultrasound surgery, present and future. , 2013, Medical physics.

[8]  Seymour Edelman,et al.  Piezoelectric polymer probe for ultrasonic applications , 1981 .

[9]  P. V. Yuldashev,et al.  Characterization of a multi-element clinical HIFU system using acoustic holography and nonlinear modeling , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[10]  L. Zhai,et al.  Measurement of high intensity focused ultrasound fields by a fiber optic probe hydrophone. , 2006, The Journal of the Acoustical Society of America.

[11]  Bradley E. Treeby,et al.  A discrete source model for simulating bowl-shaped focused ultrasound transducers on regular grids: Design and experimental validation , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[12]  Samuel M. Nagle,et al.  Challenges and Regulatory Considerations in the Acoustic Measurement of High‐Frequency (>20 MHz) Ultrasound , 2013, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[13]  Graham F. McDearmon,et al.  Fiber-Optic Hydrophone , 1990, Other Conferences.

[14]  Thomas Looi,et al.  MatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU , 2013, Journal of therapeutic ultrasound.

[15]  Satya V. V. N. Kothapalli,et al.  Acoustic field characterization of a clinical magnetic resonance‐guided high‐intensity focused ultrasound system inside the magnet bore , 2017, Medical physics.

[16]  Junho Song,et al.  Investigation of Standing-Wave Formation in a Human Skull for a Clinical Prototype of a Large-Aperture, Transcranial MR-Guided Focused Ultrasound (MRgFUS) Phased Array: An Experimental and Simulation Study , 2012, IEEE Transactions on Biomedical Engineering.