Harmonic distorition caused by electrode polarisation

Steady-state measurements of the electrical properties of electrodes immersed in physiological saline were taken with small- and large-amplitude sinusoidal voltages (30 m V-1 V) in the frequency range 0·2 mHz-2 Hz. Impedance magnitude and phase, and the first four Fourier series coefficients of the polarised current were measured. The dependence of the polarisation admittance on input current intensity was modelled with the linear relationship proposed by Schwan. This model predicts harmonics in the non-linear range for AC overpotentials up to several hundred millivolts. Observed values deviated from theoretical values. Reasons for such deviations are discussed. The study of harmonic distortion appears to be a useful tool to monitor and predict the non-linear behaviour of the interface and other dielectric phenomena.

[1]  H P Schwan,et al.  ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS * , 1968, Annals of the New York Academy of Sciences.

[2]  L. Geddes Electrodes and the measurement of bioelectric events , 1972 .

[3]  Herman P. Schwan,et al.  CHAPTER 6 – DETERMINATION OF BIOLOGICAL IMPEDANCES1 , 1963 .

[4]  John H. Busser,et al.  Principles of Applied Biomedical Instrumentation , 1968 .

[5]  J. D. Bourland,et al.  The Rectification Properties of an Electrode-Electrolyte Interface Operated at High Sinusoidal Current Density , 1987, IEEE Transactions on Biomedical Engineering.

[6]  H. P. Schwan,et al.  Linear and nonlinear electrode polarization and biological materials , 2006, Annals of Biomedical Engineering.

[7]  Banu Onaral METAL BIOELECTRODE POLARIZATION: A FREQUENCY AND TIME DOMAIN ANALYSIS. , 1978 .

[8]  D. Kell,et al.  On the nonlinear dielectric properties of biological systems , 1990 .

[9]  L. A. Geddes,et al.  The impedance of stainless-steel electrodes , 1971, Medical and biological engineering.

[10]  Banu Onaral,et al.  An algorithm for determining global parameters of minimum-phase systems with fractional power spectra , 1989 .

[11]  Douglas B. Kell,et al.  On the nonlinear dielectric properties of biological systems: Saccharomyces cerevisiae , 1990 .

[12]  L. A. Geddes,et al.  Electrical properties of metallic electrodes , 1990, Medical and Biological Engineering and Computing.

[13]  H. P. Schwan,et al.  Nonlinear phenomenon of interfacial polarization immittance of a Pt electrode , 2006, Annals of Biomedical Engineering.

[14]  Banu Onaral,et al.  Electrical Properties of Bioelectrodes , 1984, IEEE Transactions on Biomedical Engineering.

[15]  B. Onaral,et al.  Linear and nonlinear properties of platinum electrode polarisation II: time domain analysis , 1983, Medical and Biological Engineering and Computing.

[16]  B. Onaral,et al.  Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies , 1982, Medical and Biological Engineering and Computing.

[17]  Herman P. Schwan,et al.  Nonlinear AC and DC Polarization of Platinum Electrodes , 1980, IEEE Transactions on Biomedical Engineering.

[18]  H. Schwan,et al.  Linear and nonlinear properties of platinum electrode polarisation III: Equivalence of frequency-and time-domain behaviour , 2006, Medical and Biological Engineering and Computing.

[19]  H P Schwan,et al.  Alternating current electrode polarization , 1966, Biophysik.