A model of vertebral trabecular bone architecture and its mechanical properties.

An idealized, structural model of vertebral trabecular bone is presented. The architecture of the model (thick vertical columns and thinner horizontal struts) is based on studies of samples taken from the central part of vertebral bodies from normal individuals aged 30 to 90 years. With trabecular diameters and spacings typical for persons aged 40, 60, and 80 years respectively, the model accounts reasonably well for age-related changes in vertical and horizontal stiffness and trabecular bone volume, as seen in experimental data. By introducing a measure for the randomness of lattice joint positions in the modeled trabecular network, it is demonstrated that the apparent stiffness varies by a factor of between 5 and 10 from a perfect cubic lattice to a network of maximal irregularity, even though trabecular bone volume remains almost constant. A considerable change in mechanical behaviour is also seen, without changing the overall trabecular bone volume, when the bone material is slightly redistributed among vertical and horizontal trabeculae. It is concluded that measured bone mass should not be the sole indicator of trabecular bone biomechanical competence (stiffness and stress). It is crucial that measurements of bone density are considered in combination with a detailed description of the architecture.

[1]  L. Mosekilde,et al.  Biomechanical competence of vertebral trabecular bone in relation to ash density and age in normal individuals. , 1987, Bone.

[2]  A. Parfitt The coupling of bone formation to bone resorption: a critical analysis of the concept and of its relevance to the pathogenesis of osteoporosis. , 1982, Metabolic bone disease & related research.

[3]  Frost Hm,et al.  The mechanostat: a proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents. , 1987 .

[4]  H. Frost The skeletal intermediary organization. , 1983, Metabolic bone disease & related research.

[5]  J. Lewis,et al.  Properties and an anisotropic model of cancellous bone from the proximal tibial epiphysis. , 1982, Journal of biomechanical engineering.

[6]  L. Mosekilde Iliac crest trabecular bone volume as predictor for vertebral compressive strength, ash density and trabecular bone volume in normal individuals. , 1988, Bone.

[7]  H J Gundersen,et al.  Unbiased stereologic estimation of surface density in bone using vertical sections. , 1987, Bone.

[8]  A. Parfitt,et al.  Trabecular bone architecture in the pathogenesis and prevention of fracture. , 1987, The American journal of medicine.

[9]  L. Mosekilde Age-related changes in vertebral trabecular bone architecture--assessed by a new method. , 1988, Bone.

[10]  L. Mosekilde,et al.  Sex differences in age-related loss of vertebral trabecular bone mass and structure--biomechanical consequences. , 1989, Bone.

[11]  D R Carter,et al.  Mechanical properties and composition of cortical bone. , 1978, Clinical orthopaedics and related research.

[12]  R M Rose,et al.  Quantitative studies of human subchondral cancellous bone. Its relationship to the state of its overlying cartilage. , 1974, The Journal of bone and joint surgery. American volume.

[13]  F. Melsen,et al.  Histomorphometric Analysis of Normal Bone From the Iliac Crest , 1978, Acta pathologica et microbiologica Scandinavica. Section A, Pathology.

[14]  R. Rose,et al.  Buckling studies of single human trabeculae. , 1975, Journal of biomechanics.

[15]  C. K. Jackson,et al.  The scanning electron microscope in studies of trabecular bone from a human vertebral body. , 1971, Journal of anatomy.

[16]  L. S. Matthews,et al.  Comparison of the trabecular and cortical tissue moduli from human iliac crests , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  L. Gibson The mechanical behaviour of cancellous bone. , 1985, Journal of biomechanics.