Robust pulse rate variability analysis from reflection and transmission photoplethysmographic signals

Finger and forehead pulse photoplethysmographic (PPG) signals are compared as a surrogate for the electrocardiogram (ECG) in Heart Rate Variability (HRV) analysis during tilt table test. PPG signals are usually corrupted by motion artifacts. In this work, robust algorithms for pulse rate estimation have been applied. Classical time and frequency domain indices in the low frequency (LF) and high frequency (HF) bands have been estimated from pulse rate variability (PRV) derived from both PPG signals. These PRV indices have been compared with those obtained from the reference HRV derived from the ECG. The relative error (median/interquartile range) between PRV and HRV indices are comparable during early and later supine position in the forehead and finger signals (5.27/7.95% vs 5.88/7.87% in the LF band, 6.84/13.23% vs 7.08/12.50% in the HF band, 2.86/4.58% and 3.17/4.43% in the SDSD index during early supine position in the forehead and finger, respectively). The relative error indices estimated during the tilt were higher than during supine position, with slightly better performance in the forehead than in the finger (9.60/11.68% vs 5.28/18.64% in the LF band, 23.35/37.07% vs 35.94/81.95% in the HF band, 5.97/18.82% vs 12.71/49.03% in the SDSD index, during tilt in the forehead and finger, respectively). These results suggest that recordings on the forehead seem to provide better performance for the PRV analysis in non-stationarity environments.

[1]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .

[2]  Jesús Lázaro,et al.  Pulse Rate Variability Analysis for Discrimination of Sleep-Apnea-Related Decreases in the Amplitude Fluctuations of Pulse Photoplethysmographic Signal in Children , 2014, IEEE Journal of Biomedical and Health Informatics.

[3]  Eduardo Gil,et al.  Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children , 2008, Biomed. Signal Process. Control..

[4]  Pablo Laguna,et al.  Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal , 2003, IEEE Transactions on Biomedical Engineering.

[5]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[6]  Mikko Peltokangas,et al.  Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[7]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[8]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[9]  Walter Karlen,et al.  Pulse rate variability compared with heart rate variability in children with and without sleep disordered breathing , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[10]  Pablo Laguna,et al.  A wavelet-based ECG delineator: evaluation on standard databases , 2004, IEEE Transactions on Biomedical Engineering.

[11]  P. Laguna,et al.  Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions , 2010, Physiological measurement.