Potencial de economia de energia elétrica através do uso da luz natural e da ventilação híbrida em edifícios comerciais em Florianópolis

The aim of this study is to estimate the electricity savings potential by using daylighting integrated with artificial lighting systems and hybrid ventilation in commercial buildings located in Florianopolis, Brazil. This research work was based on computer simulations using EnergyPlus and Daysim programmes. Commercial building models with three geometries, three room sizes per geometry, four orientations and ten window areas per model were simulated. The models were examined in four case studies. In Case 1 (reference) the building operates with artificial lighting and air-conditioning systems. Case 2 presents the integration of daylight and artificial light with air-conditioning. In Case 3 hybrid ventilation and artificial lighting were used. In Case 4, the integration of daylight and artificial light with hybrid ventilation was used. The electricity consumption in Case 1 were compared with those in the other cases. Hence, the potential for electricity savings by using daylighting and hybrid ventilation was estimated. The main conclusion was that the use of daylighting and hybrid ventilation in commercial buildings located in Florianopolis presents a potential of up to 64.9% savings in electricity and such strategies can be used to improve energy efficiency in this type of buildings.

[1]  Malcolm J. Cook,et al.  Low energy architecture for a severe US climate: Design and evaluation of a hybrid ventilation strategy , 2007 .

[2]  Gail Brager,et al.  Occupant satisfaction in mixed-mode buildings , 2009 .

[3]  Enedir Ghisi,et al.  Analysis of daylight calculated using the EnergyPlus programme , 2010 .

[4]  Marcio José Sorgato Desempenho térmico de edificações residenciais unifamiliares ventiladas naturalmente , 2012 .

[5]  F. O. R. Pereira,et al.  Simulação computacional integrada para a consideração da luz natural na avaliação do desempenho energético de edificações , 2010 .

[6]  Ricardo Forgiarini Rupp,et al.  What is the most adequate method to assess thermal comfort in hybrid commercial buildings located in hot-humid summer climate? , 2014 .

[7]  Andreas K. Athienitis,et al.  Experimental study of the thermal performance of a large institutional building with mixed-mode cooling and hybrid ventilation , 2012 .

[8]  Mattheos Santamouris,et al.  Experimental performance investigation of natural, mechanical and hybrid ventilation in urban environment , 2008 .

[9]  Ricardo Forgiarini Rupp Dimensionamento de área de janela em edificações comerciais: integração da iluminação natural com a artificial e utilização da ventilação híbrida , 2011 .

[10]  Christian Inard,et al.  Prediction of hybrid ventilation performance using two simulation tools , 2006 .

[11]  Brian J. Polidoro,et al.  Impact of adaptive thermal comfort on climatic suitability of natural ventilation in office building , 2011 .

[12]  K. Lomas,et al.  Hybrid ventilation for low energy building design in south China , 2009 .

[13]  Marina Vasconcelos Santana Influência de parâmetros construtivos no consumo de energia de edifícios de escritório localizados em Florianópolis/SC , 2006 .

[14]  Moncef Krarti,et al.  A simplified method to estimate energy savings of artificial lighting use from daylighting , 2005 .

[15]  Gregory M. Maxwell,et al.  An empirical validation of the daylighting algorithms and associated interactions in building energy simulation programs using various shading devices and windows , 2007 .

[16]  Magali Bodart,et al.  Lighting energy savings in offices using different control systems and their real consumption , 2008 .

[17]  Baruch Givoni,et al.  Comfort, climate analysis and building design guidelines , 1992 .

[18]  Ana Cristina Franco Magalhães,et al.  O uso da mucilagem de cacto em pastas de gesso: efeitos na absorção de água e na resistência à flexão estática , 2010 .

[19]  Magali Bodart,et al.  Global energy savings in offices buildings by the use of daylighting , 2002 .