A networked modular hardware and software system for MRI-guided robotic prostate interventions

Magnetic resonance imaging (MRI) provides high resolution multi-parametric imaging, large soft tissue contrast, and interactive image updates making it an ideal modality for diagnosing prostate cancer and guiding surgical tools. Despite a substantial armamentarium of apparatuses and systems has been developed to assist surgical diagnosis and therapy for MRI-guided procedures over last decade, the unified method to develop high fidelity robotic systems in terms of accuracy, dynamic performance, size, robustness and modularity, to work inside close-bore MRI scanner still remains a challenge. In this work, we develop and evaluate an integrated modular hardware and software system to support the surgical workflow of intra-operative MRI, with percutaneous prostate intervention as an illustrative case. Specifically, the distinct apparatuses and methods include: 1) a robot controller system for precision closed loop control of piezoelectric motors, 2) a robot control interface software that connects the 3D Slicer navigation software and the robot controller to exchange robot commands and coordinates using the OpenIGTLink open network communication protocol, and 3) MRI scan plane alignment to the planned path and imaging of the needle as it is inserted into the target location. A preliminary experiment with ex-vivo phantom validates the system workflow, MRI-compatibility and shows that the robotic system has a better than 0.01mm positioning accuracy.

[1]  Cosme Furlong,et al.  A Miniature MRI-Compatible Fiber-optic Force Sensor Utilizing Fabry-Perot Interferometer , 2011 .

[2]  T. Fielding,et al.  An image-guided magnetic resonance-compatible surgical robot. , 2008, Neurosurgery.

[3]  Gregory S. Fischer,et al.  High-Field MRI-Compatible Needle Placement Robots for Prostate Interventions: Pneumatic and Piezoelectric Approaches , 2012 .

[4]  Gabor Fichtinger,et al.  Preliminary evaluation of a MRI-compatible modular robotic system for MRI-guided prostate interventions , 2010, 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[5]  Gabor Fichtinger,et al.  Integrated navigation and control software system for MRI-guided robotic prostate interventions , 2010, Comput. Medical Imaging Graph..

[6]  Bo Yang,et al.  Design and implementation of a pneumatically-actuated robot for breast biopsy under continuous MRI , 2011, 2011 IEEE International Conference on Robotics and Automation.

[7]  Ron Kikinis,et al.  3D Slicer , 2012, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[8]  Gabor Fichtinger,et al.  OpenIGTLink: an open network protocol for image‐guided therapy environment , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[9]  Iulian Iordachita,et al.  Reconfigurable MRI-guided robotic surgical manipulator: Prostate brachytherapy and neurosurgery applications , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  A. Patriciu,et al.  A New Type of Motor: Pneumatic Step Motor , 2007, IEEE/ASME Transactions on Mechatronics.

[11]  Constantinos Mavroidis,et al.  Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. , 2007, Annual review of biomedical engineering.

[12]  Conor J. Walsh,et al.  A Patient-Mounted, Telerobotic Tool for CT-Guided Percutaneous , 2008 .

[13]  Hao Su,et al.  Closed-Loop Actuated Surgical System Utilizing Real-Time In-Situ MRI Guidance , 2010, ISER.

[14]  R. Gan,et al.  Proceedings of the SEM Annual Conference and Exposition on Experimental and Applied Mechanics 2007 , 2007 .

[15]  Hao Su,et al.  Haptic system design for MRI-guided needle based prostate brachytherapy , 2010, 2010 IEEE Haptics Symposium.

[16]  D. Caleb Rucker,et al.  A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study , 2012, 2012 IEEE International Conference on Robotics and Automation.

[17]  Nobuhiko Hata,et al.  High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions , 2011, MMVR.

[18]  M Steinbuch,et al.  Modeling and Waveform Optimization of a Nano-motion Piezo Stage , 2011, IEEE/ASME Transactions on Mechatronics.

[19]  Alexandru Patriciu,et al.  “MRI Stealth” robot for prostate interventions , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[20]  Hao Su,et al.  Real-time MRI-guided needle placement robot with integrated fiber optic force sensing , 2011, 2011 IEEE International Conference on Robotics and Automation.

[21]  Hermano Igo Krebs,et al.  A robot for wrist rehabilitation , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  G.S. Fischer,et al.  MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement , 2008, IEEE/ASME Transactions on Mechatronics.